Huato HE70 Series Bedienungsanleitung

User’s Guide
HE70X/80X Handheld thermocouple
thermometer /data logger
HE81X Handheld temperature &
humidity thermometer/data logger
E-mail: [email protected]
www.huato.cn
Talk to our sales
and shop online at

The information contained in this document is believed to be correct, but HUATO accepts no liability for any errors it contains, and reserves
the right to alter specifications without notice.
www.huato.cn [email protected]
HUATO HUATO ELECTRIC CO., LTD.
Toll-Free: 0755-29977605
Customer Service: 0755-29977605
Engineering Service: 0755-29977605
Fax: +86-755-29748856
E-mail: [email protected]
Headquarters:
For Other Locations Visit www.huato.cn

HE70X/HE80X/HE81X Series Table of
Contents
Table of Contents
Section
......................................................................................
Page
Section 1 Introduction ........................................................................................ 1
1.1 HE70X and HE80X product introduction ................................ 1
1.1.1 Introduction ......................................................................... 1
1.1.2 Features ............................................................................... 1
1.1.3 Applications ........................................................................ 1
1.1.4 Data Logger Model ............................................................ 1
1.1.5 Temperature Data Logger Appearance .......................... 2
1.1.6 Single-channel LCD Screen ............................................... 2
1.1.7 Two-channel LCD Screen .................................................. 3
1.1.8 Four-channel LCD Screen ................................................. 4
1.2 81X product introduction ........................................................... 5
1 2.1.1 Introduction ...................................................................... 5
1.2.2 Features ............................................................................... 5
1.2.3 Applications ........................................................................ 5
1.2.4 Data Logger Model ............................................................ 5
1.2.5 Temperature and Humidity Data Logger Appearance. 6
1.2.6 Temperature and Humidity Data Logger Screen .......... 7
1.3 Button function instructions ....................................................... 8
4.1 LCD Screen Dim .......................................................................... 15
4.2 Data & Time Error ........................................................................ 15
4.3 Software "Runtime Error" .......................................................... 15
4.4 Check COM Port Number ......................................................... 15
Section 2 Instal2ation and Instruction .......................................................... 9
Section 3 Attention ............................................................................................. 15
Section 4 FAQ ...................................................................................................... 15
2.1 Software Installation ................................................................... 9
2.1.1 The Requirement of the Computer Hardware ............... 9
2.1.2 Install Driver & Software................................................... 9
2.2 How to Read and Configure the Logger ................................. 10
2.2.1 Read and Configure the Logger's Settings ..................... 10
2.2.2 Setting Parameters Description ........................................ 11
2.3 Download the Logging Data ...................................................... 12
2.4 View Data Sheet ........................................................................... 13
2.5 Exporting Logs from LogPro ..................................................... 13
2.6 Delete Records in the Logger ..................................................... 14
2.7 Check the Save File in File List .................................................. 14

HE70X-80X series is thermocouple thermometer. It can support 8 types thermocouple
sensors (such as K, J, E, T, N, S, R, B), measuring -200degC to 1800degC with different
sensor type suitable for the exact applications. HE70X-80X series are widely applied
in industrial production fields, food processing industry, pharmaceutical industry
and research testing fields as well as other temperature monitoring applications.
1.1.2 - Features
• 4 Channels T1/T2/T3/T4 temperatures are displayed separately.
• Manual recording and reading functions (88 groups), large capacity broken
storage, can store 36,000 sets of data.
• The input isolation protection voltage is 350Vp-p between any channel.
• Unique design, ergonomics, protection of the sensor, beautiful appearance.
• Host Size(L x H x D): 189mm x 69mm x 44mm.
• LCD Screen Size: 54mm x 44mm.
1.1.3 - Application
• Industrial production.
• Food processing.
• Pharmaceutical.
• Research
There are no user serviceable parts inside your unit. Attempting to repair or service your
unit may void your warranty.
Introduction
1
NOTE:
1
1.1.1 - Introduction
Section 1.1 - HE70X and HE80X product introduction
1.1.4 - Data Logger Model
Model Temperature
Channel
Temperature
Accuracy
Handheld Recording
Capacity
Measuring
Range
Auto Recording
Capacity
HE701
±0.8℃±2‰FS
±0.8℃±2‰FS
-200~1800℃
36,000
(none)
88
-200~1800℃88
HE702
HE704
HE801
HE802
HE804
1
2
4
1
2
4

1.1.5 - Temperature Data Logger Appearance
(HE701/HE702/HE704/HE801/HE802/HE804)
1.1.6 - Single-channel LCD Screen (HE701 ,HE801)
2
Introduction 1
9.
10.
11.
12.
13.
14.
15.
16.
Manual recording function button
Model label
USB port & DC power Jack
(9V, 3.5mm)
Hole for fixed frame
Battery cover
701/801 cap(sensor port)
702/802 cap(sensor port)
704/804 cap(sensor port)
1.
2.
3.
4.
5.
6.
7.
8.
LCD Screen
LOG Button
Setup Button
ON/OFF
OK Button
Maximum and minimum
checking buttons
Manual recording data
checking button
The previous data checking
button
+
T1
_
+
T1
+
T2
+
T3
+
T4
_ _ _ _
+
T1
+
T2
_ _
10
4
5
6
7
1 11
12
14
15 16
13
2
8
9
3
DATA LOG GER
THERMOM ETER
804
LOG SETUP
IN
OK
1
2
3
4
5
6
7
8
9
10
11
20
19
18
14
13
12
17
16
15
DEL
MIN
MAX
REL
SETUP
TYPE:
HIGH LOW
LOG
MEM
℃
℉
℃
℉

Introduction
1
3
1.1.7 - Two-channel LCD Screen (HE702 ,HE802)
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
Count for auto-recording and
manual-recordingdata.
This symbol shows being the
manual-recording checking status.
Clock symbol.
Time display area.
This symbol shows instruments being
the connection status with PC.
Maximum and minimum data display area.
This symbol shows being the maximum or
minimum data checking status.
Symbol for temperature unit.
This symbol shows being the backlight
status.
This symbol shows the setting limits are
being exceeded.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Sensor type symbol display area.
Temperature data display area.
This symbol shows being the
setup status.
This symbol shows being the manual
recording data checking status.
This symbol shows being the maximum
and minimum data checking status.
This symbol shows being the holding
fixed measuring data status.
This symbols shows that data can be
deleted.
This symbol shows instrument is
supported by external DC power.
Battery status indication.
This symbols shows being the logging
status (HE80x only).
10.
11.
12.
13.
14.
16.
17.
18.
Count for manual-recording or
auto-recording data
Symbol for clock
Year/month-date/clock alternate display area
Instrument is being connected with PC.
Manual-recording data checking status.
Display area for channel 1 and channel 2.
Symbols for temperature unit for channel 1
and channel 2.
Maximum or minimum data checking status
Holding fixed measuring data status
1.
2.
3.
4.
5.
6.
7.
8.
9.
Setup mode.
Maximum/Minimum data checking
status.
Sensor type symbol display area
Symbol for channel 1 and channel 2.
Shows that the setting limits for channel
1 or channel 2 are being exceeded.
logging status(HE80x only).
Manual-recording data can be deleted.
Instrument is being supported by DC
external power Battery status indication.
Battery status indication.
TYPE:
SETUP HIGH LOW
MAX
MIN
℃℉
℃℉
DEL
LOG
MEM
T1
T2
4
3
2
1
5
7
6
8
9
10
18
16
15
13
12
14
11
17

Introduction 1
4
10.
11.
12.
13.
14.
15.
16.
17.
18.
Count for auto-recording or
manual-recording data.
Symbol for clock.
Manual-recoding data checking status.
Instrument is being connected with PC.
Manual-recoding data checking status.
Setting limits are being exceeded.
Temperature unit for channel 1, channel
2, channel 3 and channel 4.
Maximum and minimum data checking
status.
Holding fixed measuring data status.
1.
2.
3.
4.
5.
6.
7.
8.
9.
Setup mode.
Maximum or minimum data checking
status.
Sensor type symbol display area.
T1,T2,T3,T4 for channel 1, channel 2,
channel 3 and channel 4 respectively.
Data symbol for channel 1, channel 2,
channel 3 and channel 4.
Logging status (HE80x only).
Manual-recording data can be deleted.
Instrument is being connected with PC.
Battery status indication.
1.1.8 - Four-channel LCD Screen (HE704 ,HE804)
1
2
3
4
515
14
13
12
11
16
17
18
6
7
8
9
10
TYPE:
SETUP HIGH LOW
MAX
MIN
℃℉℃℉
℃℉ ℃℉
DEL
LOG
MEM
T3
T1 T2
T4

Introduction
1
5
HE81x series Temperature and Humidity Data Logger, they are Comprehensive
temperature and humidity measuring instruments which can measure the RH, air
temperature, it has advanced functions such as backlight, check for MAX and MIN
value and USB port telecommunication to download all recorded data.
1.2.2 - Features
• Adopt Swiss imported high precision temperature and humidity sensor.
• Manual recording and reading functions (88 groups), large capacity broken
storage, can store 36,000 sets of data.
• Unique design, ergonomics, protection of the sensor, beautiful appearance.
• Host Size(L x H x D): TH Series (275mm x 69mm x 44mm)
EX Series (189mm x 69mm x 44mm).
• LCD Screen Size: TH/EX Series (54mm x 44mm).
1.2.3 - Application
• Industrial production.
• Food processing.
• Pharmaceutical.
• Air Condition / Heater Test.
There are no user serviceable parts inside your unit. Attempting to repair or service your
unit may void your warranty.
NOTE:
1.2.1 - Introduction
Section 1.2 - HE81X product introduction
1.2.4 - Data Logger Model
Model Temperature
Range
Humidity
Range
Humidity
Accuracy
Temperature
Accuracy
Auto Recording
Capacity
HE810-TH 0~100%RH
0~100%RH
±0.5℃
36.000
±5%RH
±0.3℃±3%RH
HE810-EX
HE815-TH
HE815-EX
-20~70℃
-40~85℃
-20~70℃
-40~85℃

Introduction 1
8.
9.
10.
11.
12.
13.
14.
The previous data checking button
Manual recording function button
Model label
USB port & DC power Jack
(9V, 3.5mm)
Hole for fixed frame
Battery cover
Built-in sensor
1.
2.
3.
4.
5.
6.
7.
LCD Screen
LOG Button
Setup Button
ON/OFF
OK Button
Maximum and minimum
checking buttons
Manual recording data checking
button
1.2.5 - Temperature and Humidity Data Logger Appearance
(HE810-TH/HE810-EX/HE815-TH/HE815-EX)
6
10
4
5
6
7
111
12
14
13
2
8
9
3
DATA LOG GER
810
LOG SETUP
IN
OK
HYGRO-THE RMOMETER
HE810-TH/HE815-TH
HE810-EX/HE815-EX)
15
Ch1

8.
9.
10.
11.
12.
13.
14.
15.
The previous data checking button
Manual recording function button
Model label
USB port & DC power Jack (9V, 3.5mm)
Hole for fixed frame
Battery cover
External Cable Length 3 meter
81x-EX Cap(Sensor Port)
1.
2.
3.
4.
5.
6.
7.
LCD Screen
LOG Button
Setup Button
ON/OFF
OK Button
Maximum and minimum checking
buttons
Manual recording data checking
button
7
Introduction
1
10
4
5
6
7
1 11
12
14
13
2
8
9
3
DATA LOG GER
HYGRO-THE RMOMETER
810
LOG SETUP
IN
OK
1.2.6 - Two-channel LCD Screen
(HE810-TH/HE810-EX/HE815-TH/HE815-EX )
TYPE:
SETUP HIGH LOW
MAX
MIN
℃℉
℃℉%RH
DEL
LOG
MEM
T1
T2
4
3
2
1
5
7
6
8
9
10
19
16
15
13
12
14
11
17
18
℃
%RH
Dieses Handbuch passt für folgende Modelle
8
Inhaltsverzeichnis
Andere Huato Thermometer Handbücher