HW Group WLD2 Bedienungsanleitung

HW group
2Safety warning
Safety warning
The device meets the requirements of standards valid in the Czech Republic, has undergone live
testing and is delivered in operational condition. To maintain the device in this condition, it is
necessary to observe the safety and device maintenance requirements set forth below.
If the device is not used in the manner recommended by the manufacturer, the security offered
by the device may be breached!
The power socket or point of disconnecting the device from power supply must be freely accessible!
The device must not be used in particular if:
• It is visible damaged.
• It does not work properly.
• There are loose parts inside the device.
• It was exposed to long-term humidity or got wet.
• It underwent unqualified repair by unauthorised personnel.
• The power adapter or its supply cable are visible damaged.
• If the device is used in a manner other than the designated manner, the protection provided
by the device may be breached.
• The switch or fuse and other power surge protection resources must be part of the overall
construction unit.
The manufacturer is liable for the device only if it is powered by the supplied or approved power source.
Should you have any problems with installation and start-up, you can contact our technical support:
HW group s.r. o.
http://www.hw-group.com
email: support@HWg.cz
Rumunská 26/122
Prague, 120 00
Phone: +420 222 511 918
Before contacting technical support, prepare the precise model of your device (on the manufacturing label
and the firmware version (see below), if you know it.

WLD2 3
Contents
Contents
Safety warning 2
Contents 3
Features 4
Usage examples 4
Basic features 5
Scalability 5
Comparison of HWg-WLD and WLD2 5
Connectors and connections 6
First start-up 7
WWW interface 9
Home tab 9
General Setup tab 10
Security tab 11
WiFi tab 12
Sensors tab 15
Outputs tab 16
E-mail tab 17
SMS tab 18
Alarms tab 19
SNMP tab 20
Time tab 22
Portal tab 23
System tab 25
Technical parameters 27
Physical dimensions 28
WiFi Radio 29
WiFi signal strength 29
Connecting WLD2 to the SensDesk portal 30
Using the mobile phone app 35
Firmware upgrade in WLD2 units 36

HW group
4
Features
WLD 2 – Quad water leak detector with WiFi and Ethernet
WLD2 is a WiFi / Ethernet water leak detector with support for WWW, SNMP and PoE. To detect
leaking liquids, it uses sensing cables. With braided liquid-absorbing cables, it is possible to
detect even the smallest volumes of liquids, such as condensation from A/C pipes or water
leaks in general – before a critical volume of water, ethylene glycol, or another conductive
liquid forms and damages become costly. In addition to flooding, the detector also detects
disconnected or damaged sensing cable for increased reliability.
Thanks to WiFi connectivity, the WLD2 WiFi water leak detector can be installed in hard-to-
access places and, in case of flooding, send an alert via e-mail, SNMP trap, or – with an external
SMS gateway by HW group – even send a text message or dial a phone number. Of course, in
critical applications, it can also communicate via wired Ethernet and can be powered with PoE.
WLD2 can be connected to the SensDesk portal using the HWg-Push protocol, as well as to
standard monitoring systems thanks to SNMP and SNMP Trap support. Flooding can be also
indicated by switching a remote output (e.g. a relay) over the network (Box-2-Box mode with
aPoseidon2 or Damocles2 unit), independently for each sensing cable.
Compared to HWg-WLD, up to 4 independent detecting cables can be connected to the WLD2
to help locate the leak more accurately.
RACK
1
RACK
2
RACK
3
RACK
4
RACK
5
FREEZER
3
FREEZER
1
AIRCONDITION
1
Terminator
Connection cable
Prolong cable
AIRCONDITION
2
AIRCONDITION
3
FREEZER
2
RACK
6
Detection cable
– max. 85 m
Usage examples
• Water detection under raised floors.
• Leaky pipe detection (cable wrapped along the pipe).
• Protection against floods from skylights – sensing cable routed along the walls.
• Detection of water leaks in drip trays.
• Detection of water leaks under air-conditioning outlets.
WLD2 – User Manual

WLD2 5
Basic features
Basic features
• Simple installation, support for automatic network configuration via DHCP.
• Intuitive WWW interface for fast and easy installation.
• Ability to communicate over WiFi (external antenna for extended range, support for 2.4GHz,
2.11 b/g/n) and Ethernet at the same time.
• With support for up to 4 sensing cables (each max. 85m), detection capabilities can be scaled
and the source of the leak more easily identified.
• The sensing cable can be fixed using clips or adhesive tape.
• WLD2 signals the following states: OK / Flooded / Sensing cable fault.
• Flooding alerts can be send as a standard e-mail, or as a text message (SMS) through a SMS
gateway available from HW group.
• Detected leaks or WLD sensing cable disconnections can be signaled by activating a relay
output at a Poseidon2 or Damocles2 unit over the Ethernet.
• WLD2 can be easily mounted on a wall or in a 19" cabinet.
• Powered over PoE or from an external adapter.
Scalability
WLD2 supports up to 4 independent sensing cables. This makes it easier to locate the source
of the leak. Each detection circuit can consist of up to 85m of sensing cable + up to 100m of
connecting cable.
Total length max. 185 m
Sensing cable 85 m +connecting cable 100 m
50 m 10 m max. 98 m 2 m 2 m
T – Terminator
The circuit can be extended with
a2-wire connecting cable at any place.
Comparison of HWg-WLD and WLD2
Function HWg-WLD WLD2
WLD circuits 1 4
Ethernet
WiFi
HTTPs
External antenna
TLS
SensDesk support
PoE
Remote outputs 1 4

HW group
6
Connectors and connections
WLD sensing cable
WLD1 WLD2 WLD3 WLD4
Antenna
Power
5V
Reset
Ethernet
WiFi
Connectors
• Ethernet – for a wired internet connection
in case of LAN operation, or for initial
configuration in case of WiFi operation. Can
be used to power the device via PoE (Power
over Ethernet).
• WLD1 – WLD4 – for connecting up to 4 liquid
sensing cables.
• Power – connector for a 5V power supply if the
device is powered from an external adapter.
LED indicators
• Link – green LED indicates an active network
connection.
• Activity – flashing yellow LED indicates
ongoing communication over the wired
network connection.
• WiFi – blue LED indicates an active connection
to a WiFi Access Point. While establishing
the connection, flashing LED indicates status.
• WLD LED – 4 red LEDs above the connectors
for the sensing cable. When lit, the respective
circuit is in Alarm – liquid is detected or the
cable is disconnected.
Button
• Reset – to reset the device to factory defaults.
1. Turn the device off.
2. Press and hold the button.
3. Turn the device on and hold the button
for another 5 seconds.
4. All LEDs light up in sequence.
5. Turn the device on again, factory defaults
are restored.
WLD2 – User Manual

WLD2 7
First start-up
First step
Cable connection
• Connect the device to the Ethernet (direct cable to the switch, crossed to PC).
• Connect the power adapter to the grid and connect it to the device power supply connector.
• The green LED in the Power & Mode RJ45 connector will light up.
• If connection to the Ethernet, is functional, the LINK (yellow) LED should light up shortly afterwards
and switch off during data transfer to the Ethernet (Activity signalisation).
• A quickly flashing yellow LINK LED signalises communication with the DHCP server.
Setting of the IP address - HWg-Config
The HWg-Config program is located in the main director on the enclosed CD (version for Windows
and Linux).
The program can be downloaded at www.HW-group.com Software -> HWg-Config.
• Click on the icon to launch the HWg-Config program – the program automatically searches for
connected devices.
• Launch the search by clicking on the Find Devices icon.
• The program searches for devices in your local network. Click on the MAC address of the device
to open the dialogue window for device settings.
1
2
First start-up

HW group
8
Set device network parameters:
• IP address/HTTP port (80 by standard)
• Your network ask
• IP address of your network gateway
• Device name (optional parameter)
Save the settings by clicking on Apply Changes.
Restore default settings:
• Right-click on the device MAC address. The default
values from the HWg-Config can be restored by
software mode during the first 60 settings after
start-up.
• Press the RESET button, hold it down and
connect the power source. Hold the button down
for another 5 seconds until all the LEDs light up.
Device website
Options of opening the website:
• Enter the device IP address in the browser window.
• Click on the IP address in the HWg-Config program.
• Click on the underlined IP address in the HWg-Config application.
First step
3
WLD2 – User Manual

WLD2 9
WWW interface
Home tab
Base Information section
• Device Name – the device name serves to distinguish specific devices in larger installations. Can
be set in the General Setup tab.
• Time – current device time. The time can be set automatically from the internet or manually
in the Time tab. In the case of automatic setting, the correct value is the indicator of device
access to the internet.
• Date – current device date. The date can be set automatically from the internet or manually
in the Time tab. In the case of automatic setting, the correct value is the indicator of device
access to the internet.
Sensors
Lists the current values of sensors.
• State – input or sensor state.
• Normal – idle state, all normal.
• Disconnect – the sensing cable is disconnected or damaged.
• Flooded – liquid was detected.
• Name – sensor name for better identification in larger systems. The name can be set in the
Sensors or Digital Input tab.
• Current Value – current value including unit of measure.
WWW interface

HW group
10
General Setup tab
General section
• Device Name – device name (WLD2), allow you to distinguish individual the device in the network.
• WWW Info Text – text at the foot of the website.
• Temperature Unit – unit for displaying temperature. You can choose between Celsius / Fahrenheit/
Kelvin. The Safe Range values will automatically be converted based on this option.
• Periodic Restart – function to improve device stability in exposed networks allowing regular
automatic restart of the device.
Network section
Only the cable connection parameters (RJ-45) are set here. Wireless connection parameters
are set in the WiFi tab.
• DHCP – permits the function of IP address setting by the DHCP server, if available. Enabling or
disabling DHCP depends on the needs of the user and network administrator.
• IP Address – IP address of the device, allocated by the network administrator.
• Network Mask – network mask, allocated by the network administrator.
• Gateway – IP address of the default gateway, allocated by the network administrator.
• DNS Primary / DNS Secondary – IP address of the DNS server, allocated by the network administrator.
WLD2 – User Manual
Inhaltsverzeichnis
Andere HW Group Sicherheitssensor Handbücher