1. General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2. Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. Configuration of the System . . . . . . . . . . . . . . . . . . 5
4. Preparation for Installation . . . . . . . . . . . . . . . . . . . 8
5. IWARM Floor Heating System Installation . . . . . . .12
6. Turning the System on and Operation . . . . . . . . . .27
7. Advices and Notes . . . . . . . . . . . . . . . . . . . . . . . . . .27
8. Your Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
9. Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
10. Plan of the Premises . . . . . . . . . . . . . . . . . . . . . . . .33
11. Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34

1. General
Dear Customer!
You have purchased a IWARM floor heating system.
Thank you for your choice. We are sure that our product
will meet all your expectations and bring warmth and
comfort in your home.
Please read the following advices carefully before
installing the system:
JWe recommend you to buy an IWARM Additional Kit
with a thermostat, temperature gage, protective cor
rugated tube for the temperature gage, and a service
box. This will ensure reliable operation of your IWARM
floor heating system.
Jmake sure that your floor area corresponds to the effi
ciency of the system you bought. Advices on how to
choose your system and recommendation for heating
cable spacing are given in the Appendix to this
instruction. Adhere to the recommended spacing
when weaving the cable. Do not allow it to approach
together closer than 60 mm.
Jbefore installing the system make sure it is suitable for
your floor finishing. IWARM system is intended for
floors with ceramic or stone tiles or into grout.
Jplan the installation of your heating cable so that it will
not be damaged during subsequent works.
Jif you do not want to apply tile immediately after your
heating system has been installed, make sure that
www.iwarm.com
Spooled Underfloor Heating Kit
2

your heating elements will not be damaged during this
time (e.g. cover the elements with cardboard or ply
wood sheets).
Jwe recommend you to use only grades of mixtures
which allow for floor heating.
Jmake sure the element heats before any tiling works
(according to instructions in paragraph 5, pages
19–20, 25).
Jtake care not to displace or damage the cable when
applying tiles.
Jread carefully the restrictions on heating system
installation and operation given in paragraph 8.
These instructions contain IWARM floor heating sys
tem installation and connection rules. Remember that
proper and long service of your floor heating system is
99 %depend on its proper installation. Follow the
instruction here when installing your floor heating system.
You can install the system on your own, or turn to either a
qualified electrician or our wiremen.
2. Application
IWARM floor heating system is a universal room elec
tric infloor heating system which can be installed under
floors with tile covering (or other decorative flooring) and
into grout. This system can operate as:
www.iwarm.com
Spooled Underfloor Heating Kit
3

1. Main heating system in detached buildings including
those where there is no any central heating system.
2. Additional (comfort) heating system. Installed
together with other heating devices and is intended to
give additional thermal comfort.
Heating system power choice is based on the follow
ing considerations:
JA heating element nominal power shall be:
— 110–120 W per square meter, min, of free floor
space (IWARM as an additional system).
— 130–150 W per square meter (IWARM as the main
heating system).
JIf IWARM is used as the main heating system, it shall
cover 70 %, min, of total floor space in the room.
Consult your sales manager or service department if
you want to use this heating system in your balconies, win
ter gardens, rooms with many windows, open doorways
and arches, or rooms with more than 4 m high ceilings.
Our qualified staff will help you to choose the right system
which will ensure sufficient heating in you home.
www.iwarm.com
Spooled Underfloor Heating Kit
4

3. System delivery kit
IWARM floor heating system consists of a reel of
heating cable element and assembly tape. A thermostat
is necessary for the reliable operation of IWARM floor
heating system. We also recommend you to buy an
I-WARM Additional Kit with a thermostat, temperature
probe, protective corrugated tube for the temperature
probe, and a service box.
Heating section (IWARM heating system) as well as a
thermostat and a service box (IWARM Additional Kit)
have certificates with their specifications and warranties.
3.1. Heating section
Heating section is a heating cable of a sertain length
with 3 m long installation cable. Connection of the heat
ing cable and installation cable, as well as terminal seal
ing are made in enclosed splicing and terminal cou
plings. These boxes are highly reliable. They are repeat
edly tested at the factory.
Sections with different nominal power have different
colors and marking to facilitate their distinguishing.
Sections specifications and wiring diagrams are given in
the Appendix to these instructions.
Heating cables of heating sections are made and test
ed according to high reliability technology. Heating sec
tions approved by Russian Compliance Certificates, Fire
Safety Certificates and Hygiene Certificate.
www.iwarm.com
Spooled Underfloor Heating Kit
5

Cable insulation is made of tough, heatresisting, non
flammable Tefzel fluoropolymer. Cable shield is made of
aluminum foil reinforced with copper line. The shield pro
vides mechanical and electrical protection and increases
heat resistance of the cable. Cable jacket is made of
heatresistant, hard PVC.
Heating cables are made of highquality materials by
leading polymer producers.
Doubleconductor cable makes it possible to feed the
section from one end only. This facilitates section laying
out in the room.
To connect IWARM section properly pay atten
tion to installation wire coloring.
Blue and brown wires go to the heating wires and are
connected to the thermostat.
Plain conductor with twisted copper wires is connect
ed with the protective shield of the cable. This conductor
has to be connected to the building grounding loop (or
neutral conductor).
www.iwarm.com
Spooled Underfloor Heating Kit
6
Green Box element
thermostat
thermostat
terminal blocks
service box
grounding loop
or neutral conductor
Coupling
muff
Heating core terminals
(blue and brown)
Screen
terminal
Termination
muff
Installation wire
(cold lead) Terminal
connections Power supply
220 VAC
Sensor
of temperature
control
circuit
IWARM section

3.2. Prepunched band installation
Prepunched band installation is used to facilitate
heating sections laying out and fixing to the floor sur
face. Pieces of tape are fixed to the subfloor. The tape
has equally spaced fixing lugs to assure equal element
spacing.
3.3. Thermostats
A thermostat allows for energy saving, turning on only
when the thermal comfort in the room needs to be sus
tained.
With programmable thermostats you can set your own
temperature schedule for a day or a week. We recommend
you to use new IWARM series thermostats.
3.4. Service box
The service box is used to appliance cords when sev
eral heating sections are installed, as well as to facilitate
sensor of temperature replacement in case of its defect.
Connections are made in twopart terminal blocks.
www.iwarm.com
Spooled Underfloor Heating Kit
7

4. Preparation for Installation
4.1. Floor Preparation
To provide long service life of the floor heating system
and to eliminate possible damages to the heating cable
during installation works you need to do some preparato
ry works.
How to prepare the surfaces to lay out the heating
cable is described below.
JConcrete floor: provide smooth, clean and dry sur
face (preliminary level uneven floor surface with any
smoothing mixture). Use primer to get better floor sur
face. Wait for the floor to dry after the surface treat
ment (according to the instructions for use).
www.iwarm.com
Spooled Underfloor Heating Kit
8
It is recommended to apply primer
to the surface
The floor surface should be
smooth, clean and dry

JCeramic floor tiles: provide clean, dry and smooth
surface without sharp edges, irregularities and so on.
JWooden floor: Secure the floor planks, cover with
waterproof plywood sheets 18 mm in thickness or any
other similar material sheets and fix them with screws
to provide reliable and stable base. It is not recom
mended to put plywood sheets onto beams or joists
such base will not have necessary mechanical
strength. Strong base is important to prevent cracks in
the mortar or adhesive mixture. Sharp edges of these
cracks can damage the heating cable.
JFloor with finishing: previous floor finishing (e.g.
laminates, cork and so on) shall be removed together
with the adhesive layer.
JFinishing (tarbitumen mixture) used as water
proofing: shall be covered with no less that 50 mm
screed. Put the heating cable onto dry screed (screed
drying time is 28 days). Consult the manufacturer if
you use any other waterproofing finishing. We recom
mend you to use high quality mixtures with polymer
plastic additives.
www.iwarm.com
Spooled Underfloor Heating Kit
9
Inhaltsverzeichnis
Beliebte Fußbodenheizungssystem Handbücher anderer Marken

LK Systems
LK Systems Minishunt M60 Bedienungsanleitung

Reznor
Reznor EFMA Bedienungsanleitung

Flextherm
Flextherm GreenCable Concrete Bedienungsanleitung

suntouch
suntouch D12 series Bedienungsanleitung

Warmup
Warmup USDW-360-120 Bedienungsanleitung

Powerblanket
Powerblanket Summerstep series Bedienungsanleitung