ICEL MD-6520 Bedienungsanleitung

MANUAL DE INSTRUÇÕES DO
MULTÍMETRO DIGITAL
MODELO MD-6520
(versão em Inglês)
Leia atentamente as instruções
contidas neste manual antes de
iniciar o uso do instrumento

Copyright©2005 LT. All rights reserved. III
SAFETY INFORMATION.........................................................................................1
QUICK START............................................................................................................3
MULTI-DISPLAY MULTIMETER..........................................................................4
INTRODUCTION .........................................................................................4
GETTING START WITH YOUR METER..............................................................5
DISPLAY ILLUSTRATION..................................................................................5
ROTARY SWITCH.............................................................................................6
TERMINALS.................................................................................................7
PUSH-BUTTON OPERATIONS ..................................................................8
HANG BELT...................................................................................................11
POWER-ON OPTION ..............................................................................................12
HOW TO ENTER SETUP MODE.........................................................................12
FACTORY DEFAULT.......................................................................................12
BAUD RATE ..................................................................................................14
PARITY CHECK..............................................................................................15
DATA BIT......................................................................................................15
ECHO ............................................................................................................16
P
RINT ONLY ..................................................................................................16
PERCENTAGE (%) SCALE FOR 4-20MAOR 0-20MAMEASURING....................17
M
INIMUM FREQUENCY MEASURING ..............................................................18
BEEP FREQUENCY .........................................................................................19
TEMPERATURE UNIT .....................................................................................20
DATA HOLD/REFRESH HOLD ........................................................................21
ENVIRONMENT TEMPERATURE ......................................................................22
AUTO POWER SAVING...................................................................................23
BACKLIT DISPLAY.........................................................................................24
DECIBEL TYPES.............................................................................................25
REFERENCE IMPEDANCE FOR DBM................................................................26
RESET TO DEFAULT ......................................................................................27
BARGRAPH...............................................................................................................28
Contents

Copyright©2005 LT. All rights reserved.
IV
ALERTING................................................................................................................29
OVERLAOD ALERT FOR VOLTAGE MEASUREMENT.......................29
INPUT WARNING......................................................................................29
CHARGE TERMINAL ALERT.........................................................................30
CAPACITY CHECK OF BATTERY......................................................................31
CALCULATION FUNCTION .................................................................................32
DYNAMIC RECORDING ..........................................................................32
DATA HOLD...............................................................................................34
TRIGGER HOLD ........................................................................................34
REFRESH HOLD ........................................................................................35
RELATIVE (ZERO) ....................................................................................36
DECIBEL DISPLAY .........................................................................................37
PEAK HOLD...................................................................................................39
REMOTE COMMUNICATION..............................................................................41
MULTI-DISPLAY MULTIMETER........................................................................43
SELECTION BY HZ BUTTON...........................................................................43
SELECTION BY DUAL BUTTON .....................................................................45
SHIFT FUNCTION BY BLUE BUTTON ............................................................47
HOW TO OPERATE................................................................................................49
AC VOLTAGE MEASUREMENT .............................................................49
DC VOLTAGE MEASUREMENT .............................................................51
ΜAMEASUREMENT ......................................................................................52
MAMEASUREMENT ......................................................................................53
%SCALE OF 4-20MA.....................................................................................54
AMEASUREMENT .........................................................................................55
RESISTANCE/ CONTINUITY MEASUREMENT....................................56
CONDUCTANCE MEASUREMENT ........................................................59
DIODE CHECK...........................................................................................61
CAPACITANCE..........................................................................................64
BIPOLAR JUNCTION TRANSISTOR.......................................................66
JFET SWITCH TEST ..................................................................................68

Copyright©2005 LT. All rights reserved. V
TEMPERATURE MEASUREMENT ....................................................................70
CALIBRATING THE METER................................................................................72
INTRODUCTION .......................................................................................72
ENVIRONMENTAL CONDITION ............................................................72
WARM UP...................................................................................................72
RECOMMENDED TEST EQUIPMENT ....................................................73
SPECIFICATIONS....................................................................................................74
GENERAL SPECIFICATION.....................................................................74
ELECTRICAL SPECIFICATIONS.............................................................76
MAINTENANCE.......................................................................................................82
SERVICE.....................................................................................................82
BATTERY REPLACEMENT .....................................................................83
HOW TO CHARGE BATTERY..................................................................85
FUSE REPLACEMENT..............................................................................90
CLEANING .................................................................................................91
STANDARD ACCESSORIES ....................................................................91
OPTIONAL ACCESSORIES ......................................................................91

Copyright©2005 LT. All rights reserved.
1
SAFETY INFORMATION
This meter is a hand-held, battery-operated instrument for testing and
troubleshooting power electronic systems. If this device is damaged or
something is missing, contact the purchasing place immediately.
A WARNING identifies conditions and actions that may cause hazard(s) to the
user; a CAUTION identifies conditions and actions that may damage this
Device. Following Table-1 explain international electrical symbols used on this
meter.
Table- 1 International Electrical Symbols
AC - Alternating Current
DC - Direct Current
AC and DC - Alternating and Direct Current
Ground
Double Insulation
See Explanation In The Manual

Copyright©2005 LT. All rights reserved. 2
SAFETY INFORMATION
Warnings and Cautions
To avoid electric shock, injury, or damage to this instrument and ensure
that you use the meter safely, follow the safety guidelines listed below:
•Read this operation manual completely before using this device and follow all
safety instructions.
•This device is for indoor use, altitude up to 2,000 m.
•Avoid working alone.
•Use the device only as specified in this manual; otherwise, the protection
provided by the meter may be impaired.
•Never measure Voltage when the current measurement is selected.
•Do not use this device if it looks damaged.
•Inspect the leads for damaged insulation or exposed metal. Replace
damaged leads.
•Disconnect the power and discharge all high-voltage capacitors before
testing in the resistance, continuity, and diode function.
•Be cautions when working above 70V DC or 33VRMS and 46.7V peak, such
voltages may cause a shock hazard.
•Always keep your hands behind the protective guard of the probe as
measuring.
•Select the proper function and disconnect the test leads from test points
before changing functions.
•Always use specified battery.
•The meter is safety-certified in compliance with EN61010 (IEC 1010-1, IEC
1010-2-031) Installation Category ΙV 600V/ III 1000V Pollution Degree 2. In
order to maintain its insulation properties, please be sure to use with the
standard or compatible test probes.
•CE requirement: Under the influence of R.F field according to standard, the
supplied test leads will pick up induced noise. To have better shielding effect,
a short-twisted lead should be used.

Copyright©2005 LT. All rights reserved.
3
QUICK START
1. Turn the function switch to select combined function for “V”.
2. Press the “Dual” button momentarily to set frequency measuring on
secondary display.
3. Connect the INPUT terminals by test leads to the source to be tested.
Figure- 1 Dual display for ACV/ Hz Measurement
WARNING
Read "SAFETY INFORMATION" before using this device.

Copyright©2005 LT. All rights reserved. 4
MULTI-DISPLAY MULTIMETER
INTRODUCTION
The meter is robust for industrial fields and laboratories. Smart charger
provides you a chance to protect Earth environment because rechargeable
battery of NiMH optional. The ambient temperature can be display with main
measurement, which can help you to do monitor the electrical value and record
environment variation, simultaneously.
Main Features:
zDCV, ACV, DCA, ACA, OHM, Diode check, Audible continuity,
Temperature, Frequency, Duty cycle and Pulse Width tests
zAC true RMS measurement for both voltage and current
zSmart Charger design without battery removed
zAmbient temperature display with main measurement
zBattery capacity indication
zBrightness LED backlight
zResistance measurement up to 50M
zConductance measurement from 0.01nS (100G) ~ 50nS
zCapacitance measurement up to 100mF.
zThe % scale readout for 4-20mA or 0-20mA measurement
zdBm with selectable reference impedance
z1ms Peak hold to catch inrush voltage and current easily
zTemperature test with the selectable 0°C compensation
zK type temperature with environment compensation selection
zFrequency, Duty cycle and Pulse width measurements.
zDynamic Recording for Min/Max/Average
zData Hold with Manual or Auto Trigger and Relative modes
zDiode and Audible Continuity Test
zBi-directional optic computer interface with SCPI commands
zSafe, precision and speed closed case calibration
z50,000 count precision True-RMS digital multi-meter and designed to
meet IEC-1010 CAT. III 1000V and CAT. IV 600V standards

Copyright©2005 LT. All rights reserved.
5
GETTING START WITH YOUR METER
Display Illustration
Figure- 2 LCD Display
Primary Display
Secondary Display for Square
wave Output and other
Auto Power Saving
Sign
Low Battery
Relative
Mode
Remote control
Dynamic
Recording
Secondary display
units
Primary
Display units
Auto Range
Data Hold
(Manual Trigger)
Diode/Audible
continuity
Alternating/
Direct Current
% 0-20: 0-20mA
% 4-20:4-20 mA
Without ambient
temperature compensation
+ or - trigger
slope for % and
ms tests
Thermal type for
temperature test
Alternating/
Direct Current
Bar-graph display for input
function
Measuring
Range

Copyright©2005 LT. All rights reserved. 6
Rotary Switch
To turn this device ON and select a function you want by turning the rotary
switch.
Table- 2 Rotary Switch position
Position Function
1
2 V
3 V
4 mV
5 Resistance/ Continuity/ nS
6
7 TEMP
8 μA
9 mA
A
10 OFF
Figure- 3 Rotary Switch for selecting function
WARNING
Be sure to remove the test leads from measuring source
or target before changing rotary switch.
1 10
2
3
4 5 6 7
8
9
Inhaltsverzeichnis
Andere ICEL Multimeter Handbücher
Beliebte Multimeter Handbücher anderer Marken

Gossen MetraWatt
Gossen MetraWatt METRAmax 6 Bedienungsanleitung

PeakTech
PeakTech 4000 Gebrauchs- und Pflegehandbuch

YOKOGAWA
YOKOGAWA 90050B Bedienungsanleitung

Gossen MetraWatt
Gossen MetraWatt METRALINE DMM16 Bedienungsanleitung

Fluke
Fluke 8846A Bedienungs- und Wartungshandbuch

Tempo Communications
Tempo Communications MM200 Bedienungsanleitung