Iconic 1100 Front Benutzerhandbuch

Iconic 1100
Including: Front, Bay, See Through, Corner and Room Divider models
INSTALLATION, SERVICING
AND USER INSTRUCTIONS
For use in IE & GB (Ireland and United Kingdom)
This appliance has been tested and certified for other countries (see technical data). However to install appliance in other
countries, modification of the appliance and its method of installation may be necessary in order to use the appliance safely and
correctly. The manual for the local language must be obtained. Contact Heat Design for further information.
IssD 22nd February 2018
File: Iconic-1100.doc

IE & GB
2
This Manual covers all models IC1100FR, IC1100BAY, IC1100CL/CR, IC1100RD, IC1100ST in pages 2-6
Iconic 1100 Front - IC1100-FR

3
Iconic 1100 Bay - ICONIC1100-3S

IE & GB
4
Iconic 1100 Corner Left &Right - IC1100-CL & CR

5
Iconic 1100 Room Divider - ICONIC1100-RD

IE & GB
6
Iconic 1100 See Through - IC1100-ST

7
ATTENTION ! - TRAVEL LOCK NUTS on Room Divider and See Through models.
There are two travel locking nuts (one either side)
These must be released by one turn each before the appliance is fired.
The nuts can be also be accessed between the Glass and the Frame.

IE & GB
8
Content
1. General Notes 9
2. User instructions. 10
2.1 First Time of Operation 10
2.2 Remote Control Overview 10
2.3 Batteries 11
2.4 Replacing the batteries 11
2.5 Setting the Transmitter code 12
2.6 To Ignite the appliance 13
2.7 To Turn the appliance OFF 13
2.8 Adjusting the Flame setting 13
2.9 Using the "Effect" Burner 13
2.10 Setting °C/24 hour or °F/12 hour clock 13
2.11 Setting the Time 13
2.12 Cleaning and Maintenance 14
3. Installation instructions. 15
3.1 Gas Connection 15
3.2 Ventilation 15
3.3 Appliance Fireplace Installation 15
3.4 Flue Connection 20
3.5 Fuel Bed Arrangements 25
3.6 Commissioning the appliance 34
4. Servicing 35
4.1 Cleaning the Ceramics 35
4.2 Servicing the Burners 35
4.3 Spare parts 36
5. Technical Information 37
5.1 Countries of Use 37
5.2 Technical Data 38

9
1. General Notes
This Heat Design gas appliance is a High Efficiency, Balanced Flue Live Fuel Effect appliance. It provides radiant
and convected heat using the latest burner technology. As well as having a variable heat output, these fires also
utilise a special control system that allows the appliance to use three burners for high output or a single burner
for lower outputs.
One of the burners will be designated as the "Main" Burner, this is the Centre, The second and third burners will
be designated as the "Effect" Burners. The Effect burners can be switched ON or Off whilst the appliance is
alight.
Before Installation, check that the local distribution conditions, nature of the gas and pressure, and adjustment
of the appliance are compatible.
This appliance is intended for use on a gas installation with a governed meter.
This Gas Installation may only be installed by a registered professional competent person (A Qualified Gas
Engineer in IE and UK). The installation must adhere to the requirements of the local and national Building
regulations and national standards. The installation manual must also be followed.
Ensure that the Flue Terminal is not in any way obstructed and is clear of vegetation, i.e. trees, shrubs etc. and
that no objects are leant against the terminal or guard.
Always clean the Window Panel before the fire is ignited. Any finger prints must be removed, as
these will be burnt into the glass and will be un-removable.
Do not operate this appliance if the glass panel has been broken (or cracked), removed or is open.
The appliance is designed to fit numerous installation situations as listed in these installation instructions.
However only flue approved by Heat Design for this appliance may be used.
This appliance is a balanced flue product and is room sealed and as such requires no additional ventilation for
operation. However an adequate supply of fresh air to maintain temperatures and a comfortable environment is
recommended.
This appliance is designed as a heating appliance, and as such will get very hot in operation; all surfaces (except
the controls and access door) are considered to be working surfaces and as such should not be touched. The
front windows and surrounds are not considered to be fully secure guards against accidental contact. It is
recommended that an approved fire screen be used if children, the elderly or persons with limited mobility are
to be present in the same area.
Do not place curtains, laundry, furniture etc. within a safe distance of 300mm of this appliance.
Do not attempt to burn rubbish on this appliance.
If this appliance is extinguished, on purpose or other, no attempt to relight should be made within 3 minutes.

IE & GB
10
2. User instructions.
2.1 First Time of Operation Standard GV60 RC (For Symax RC see Annex 1-page 39)
Before igniting the appliance, ensure that all packaging, safety stickers and any protective wrapping have been
removed, and that the glass has been cleaned, including all fingerprints from the glass as these will be burnt on
the glass otherwise.
Ensure that the room is adequately ventilated the first time that the appliance is ignited; we would recommend
opening windows if possible. Run the appliance at full setting for a few hours so that the paint gets an
opportunity to fully cure. During this period it is possible for some fumes and vapours to be given off. We would
recommend keeping children and pets out of the area at this time.