| 9
4. KEY FUNCTION AND FEATURES
PRODUCT OVERVIEW
•
enables it to detect the beginning and ending of every use. It then can determine usage
count and pattern. The installer or maintenance personnel can adjust the flushing volume
of the sensor using a direct override button or with the recorded counter information,
optimise flush count, pattern and water volume via a Bluetooth application.
OVERFLOW PROTECTION
•In case of a blockage before or after the sensor, the urinal will not flush.
MAINTENANCE DETECTION
• The sensor detects low battery power, counts usage and warning of cartridge expiry,
also waste outlet slow flow or blockage.
• All maintenance requirements are communicated via the app and directly on site with
the warning LED in the urinal water spreader.
SPREADER WARNING LED
• The warning LED in the spreader is used to give feedback to maintenance personnel with
PASSWORD PROTECTED
• Default password: IS000, can be changed to save settings.
HYBRID MODE
• The sensor will flush the urinal after a set time interval starting from the first use. After
every flush the time interval will start with the first consecutive usage. Therefore flushing
will only occur if the urinal has been used.
STANDARD MODE
•The sensor will flush the urinal after every use.
WATERLESS MODE
•The sensor will not flush the urinal, but count usage for maintenance of cartridge.
STADIUM MODE
• If the urinal is used more than two times, with less than one minute between uses, the
sensor will go into stadium mode. The urinal still flushes after every use, but with greatly
reduced flush volume. If the urinal is not used for more than one minute, the sensor will
perform a regular maintenance flush. This feature is only available within standard mode
setting.
HYGIENE FLUSH
• Flushes the urinal if it has not been used for a set time period.
FORCED FLUSH
• It is possible for the installer or maintenance personnel to flush the urinal at any time
using the app, the reset button on the sensor or optional override button.