iGenix IG9909 Bedienungsanleitung

3-in-1 Portable Air Conditioner White
Please read these instructions carefully before use and retain for future reference
Before switching on your appliance,
always check for any damage which may have been caused in transit
IG9909
USER MANUAL

2
CONTENTS
Safety Instructions...................................................................3-4
Specication .................................................................................5
Appliance Overview...................................................................6
Installation.................................................................................7-9
Operating Instructions...................................................... 10-14
Water Drainage.................................................................. 15-16
Cleaning and Maintenance ..................................................... 17
Trouble Shooting Guide.......................................................... 18
Error Codes .............................................................................. 19
Fuse Replacement.................................................................... 20
Disposal Information............................................................... 20
Igenix Warranty Information ........................................... 22-23

3
Carefully read the instructions before operating the unit. Please
retain this manual for future reference.
Important: This product is intended for domestic and light ofce
use ONLY and not for commercial, industrial or outdoor use.
When using electrical appliances, basic safety precautions should
always be followed:
1. All electrical repairs must be carried out by a qualied
electrician. Inadequate repairs may result in a major source of
danger for the user and invalidate the warranty.
2. Do not operate the unit if the plug or cord is damaged, after it
malfunctions or has been dropped or damaged in any way, it
must be repaired by a qualied electrician.
3. Make sure the unit is connected to an earthed power supply of
the correct rating. Please refer to the rating label located at the
side of the unit.
4. Leave the unit to stand for 12 hours before connecting to the
mains electricity supply after transport or when it has been
tilted (e.g. cleaning), to allow the coolant gases time to settle.
5. Use of an extension cord is not recommended with this product.
6. This unit should only be used by adults.
7. Keep the unit and its cord out of reach of children.
8. Children shall not play with the appliance.
9. Cleaning and user maintenance shall not be made by children.
10. The unit should not be used by persons with reduced physical,
sensory or mental capabilities.
11. It is not recommended to place this appliance in cupboards,
closets, boats, caravans or similar locations.
12. Do not use the unit in a wet room, such as a bathroom or
laundry room or in areas where the unit is likely to get splashed.
13. An opening in a window or wall is required to accommodate the
exhaust hose to expel the hot air.
14. Always place unit on a dry and stable surface.
SAFETY INSTRUCTIONS

4
15. Do not cover or obstruct the unit’s inlet and outlet grilles.
16. Do not insert ngers, pencils or any other objects into the
opens of the unit.
17. Avoid restarting the appliance unless 3 minutes have passed
since being turned off.This prevents damage to the compressor.
18. Do not let chemical substances come into contact with the
appliance.
19. It is not recommended to use ammable substances or vapours
such as alcohol, insecticides, petrol, etc. whist the unit is in use.
20. Do not clean the unit by spraying it or immersing in water.
21. Do not unplug the unit while it is working, this could damage the
electronic circuits.Always use the control panel to start and stop
the unit.
22. Always turn the unit off when not in use by removing the plug
from the wall socket; ensuring to pull the plug top and not
the cord.Always turn off the unit before cleaning, carrying out
maintenance or moving location.
23. Do not pull or place the electrical cable near a source of heat:
always unroll it completely to avoid dangerous overheating.
24. The lter must be used with the product at all times, when
removing it for clearing always turn the unit off and unplug from
the mains wall socket.

5
SPECIFICATION
Model IG9909
Cooling Capacity (Btu) / (W) 9000Btu / 2600W
Heating Capacity (Btu) / (W) n/a
Dehumidication at 30°C/80%RH (L/day) 31.2
Cooling Input Power (W) 1000
Heating Input Power (W) n/a
Air FlowVolume (m³/h) 300
Power Supply (Hz) 50
Compressor Rotary
Refrigerant R290
Fan Speeds High / Low
Timer Ye s
Operating Temperature (°C) 18 - 35
Energy Rated Class A
Room Size (m²) Up to 20m2
Net Weight (kg) 26
Product Dimensions (H x W x D) (mm) 695 x 340 x 340
Unit must be vented outside when in Air Cooling and Heating Modes.
For the purpose of EU regulation EN12102, this is a local air conditioner and produces less than
65dB(A) sound energy

6
APPLIANCE OVERVIEW
Front Back
Accessories
Parts Parts Name Quantity
Exhaust hose connector
Exhaust hose
Exhaust hose adapter
1 set
Window slider kit 1 set
Window slider without
hole 1 set
Remote control 1 set
Drainage hose 1 set
1. Control panel
2. Handle (both sides)
3. Castors
4. Louvres
5. Intake grille
6. Air outlet grille
7. Intake grille
8. Power cable
9. Plug xer
10. Drainage point
11. Drainage point
Exhaust Assembly
Exhaust
hose
Exhaust hose
connector
Exhaust hose
adapter

7
INSTALLATION
Warning: Leave the unit to stand for 12 hours before connecting to the mains electricity supply
after transport or when it has been tilted (e.g. cleaning), to allow the coolant gases time to settle.
Unpacking
• Open the box and remove all of the packaging and the exhaust assembly
• Grip the unit by the carry handles located on either side and carefully lift until it slides out of
the foam base
• Install the exhaust hose assembly onto the unit before switching on
Installing Exhaust Hose
Extend the exhaust hose by pulling out the two ends of
the hose.
Screw the exhaust hose into the exhaust hose
connector, turning anti-clockwise.
Screw the other end of the exhaust hose onto the
exhaust hose adaptor.
Slide the exhaust hose assembly into the exhaust duct
located on the back of the unit, ensuring the connector
has clicked into place.
Fig.1
Fig.2
Fig.3
Fig.4
Extend the side of hose
Insert

8
Positioning the Appliance
This unit can easily be moved from one room to another on the rolling castor wheels, please note
that whilst moving the unit, it should be kept in an upright position.
• The exhaust heat must be expelled through a window, door
or vented through a wall; whilst in air cooling or heating
mode. For best results it is recommended to vent through
a wall duct.
• Ensure the unit is positioned on a at and even surface,
at least 45cm away from wall, curtains, draperies, or heat
sources to ensure adequate air circulation.
• The exhaust hose can be extended from 30cm to 150cm,
but it is recommended to use as short as possible as this
will minimise the escape of any expelled air and offer better
results.
• The exhaust air must ow freely. Avoid kinks and bends in
the hose more than 30 degrees as any blockages can lead to
the unit overheating.
Warning: Do not use the unit in a wet room, such as a bathroom or laundry room or in areas
where the unit is likely to get splashed.
Important: The length of the exhaust hose has been designed according to the specication of
the appliance. Do not extend the exhaust hose with any other product as this could lead to the
unit malfunctioning
Using the Window Slider
Fig.5 Fig.6
VerticalVertical
WindowWindow
HorizontalHorizontal
WindowWindow
Window sliderWindow slider Window sliderWindow slider
The window slider kit has been designed to t most standard vertical and horizontal window
applications, however, it may be necessary for you to modify some aspects of the installation
procedures for certain types of windows.The window slider kit can be fastened with screws.
Cut on opposite
side of hole
Note: If the window opening is less than the minimum length
of the window slider kit, cut the end without the hold in it short
enough to t in the window opening. Never cut out the hole in
window slider kit.

9
Window Slider Kit Installation
A. Panel
B. Panel with one hole
C . Screw to lock window kit in place
Assembly:
• Slide panel B into Panel A and size to window width. Ensure that the window kit assembly is free
from gaps from gaps and/or air pockets when taking measurements.
• Lock the screw into the holes that correspond
• With the width that your window requires to ensure that there are no gaps or air pockets in
the window kit assembly after installation.

10
OPERATING INSTRUCTIONS
When box is lit up, this shows:
A. Timer enabled
B. Low speed fan selected
C . High speed fan selected
D. Dehumidify mode selected
E. Cooling mode selected
F. Fan mode selected
1. Timer button
2. Fan button
3. Increase temperature button
4. Display screen
5. Decrease temperature button
6. Mode button
7. ON/OFF button
EEBBAACC
11332244556677
Control Panel
Inhaltsverzeichnis
Andere iGenix Klimaanlage Handbücher

iGenix
iGenix IG9901 Bedienungsanleitung

iGenix
iGenix IG9902 Bedienungsanleitung

iGenix
iGenix IGFD7010WIFI Bedienungsanleitung

iGenix
iGenix IG9919 Bedienungsanleitung

iGenix
iGenix IG9907 Bedienungsanleitung

iGenix
iGenix IG9909WIFI Bedienungsanleitung

iGenix
iGenix IG9703 Bedienungsanleitung

iGenix
iGenix IG9706 Bedienungsanleitung

iGenix
iGenix IG9911 Bedienungsanleitung

iGenix
iGenix IG9703 Bedienungsanleitung