Innotech EAP-QUADRAT-10 Bedienungsanleitung

EAP-QUADRAT-10
Instruction Manual
© INNOTECH Arbeitsschutz GmbH. Irrtümer, Druckfehler, technische Änderungen vorbehalten!
© INNOTECH Arbeitsschutz GmbH. Errors and misprints accepted. We reserve the right to make technical changes.
DE – ACHTUNG: Die Verwendung des INNOTECH-Produkts ist erst zulässig, nachdem die
Gebrauchsanleitung in der jeweiligen Landessprache vollständig gelesen und verstanden wurde.
DE
EN – ATTENTION: Use of the INNOTECH product is only permitted after the instruction
manual has been read and fully understood in the respective language.
EN
IT – ATTENZIONE: L'utilizzo del prodotto INNOTECH è permesso solo previa lettura e
comprensione dell'intero manuale di istruzioni nella lingua del relativo paese di utilizzo.
IT
FR – ATTENTION : L'utilisation du produit INNOTECH n'est autorisée qu'après avoir
entièrement lu et compris la notice d'utilisation dans la langue du pays concerné.
FR
NL – ATTENTIE: Dit INNOTECH-product mag pas gebruikt worden nadat u de gebrui-
kershandleiding in de taal van het betreffende land gelezen en begrepen hebt.
NL
ES – ATENCIÓN: Se autorizará el uso de los productos INNOTECH una vez que se hayan
leído y entendido las instrucciones de uso en el idioma del país.
ES
PT – ATENÇÃO: O uso do produto INNOTECH apenas é permitido depois de ter lido e
compreendido na totalidade as instruções de uso na respetiva língua nacional.
PT
DK – GIV AGT: Du må først bruge et produkt fra Innotech, efter du har læst og forstået
brugsvejledningen i fuldt omfang i dit lands sprog.
DK
SV – O B S : Denna INNOTECH-produkt får inte användas förrän bruksanvisningen på
respektive lands språk har lästs igenom och förståtts.
SV
CZ – POZOR: Práce s výrobkem INNOTECH je povolena teprve po kompletním přečtení a
porozumění návodu k použití v jazyku daného státu.
CZ
PL – UWAGA: Produkty firmy INNOTECH mogą być używane dopiero po dokładnym
zapoznaniu się z całą instrukcją obsługi w ojczystym języku.
PL
SL – POZOR: Uporaba izdelka INNOTECH je dovoljena šele po tem, ko ste navodila pre-
brali v celoti v ustreznem jeziku svoje dežele in jih tudi razumeli.
SL
SK – POZOR: Produkt INNOTECH môžete používať až po prečítaní a porozumení celého
návodu na použitie pre príslušnú krajinu.
SK
HU – FIGYELEM: Az INNOTECH termékek használata csak azt követően engedélyezett,
hogy saját nyelvén elolvasta és megértette a teljes használati utasítást.
HU
TR – DİKKAT: INNOTECH ürününün kullanımına ancak ilgili ülkenin dilinde sunulmuş
olan kullanım kılavuzunun tamamen okunmasından ve anlaşılmasından sonra izin verilir.
TR
ZH – 注意:只有在仔细阅读并完全理解了当地语言的使用说明后,才能使用 INNOTECH 公司的产品。
ZH

2EAP-QUADRAT-10 / Version 170511 / www.innotech.at
EN
1TABLE OF CONTENTS
[2] DESCRIPTION OF SYMBOLS 3
[3] SAFETY INSTRUCTIONS 4
[4] COMPONENTS/MATERIAL 6
[5] PRODUCT APPLICATION/APPROVAL 7
[6] INSPECTION 8
[7] WARRANTY 9
[8] SIGNS & MARKINGS 9
[9] DIMENSIONS 10
[10] INSTALLATION SUBSTRUCTURE 11
[11] INSTALLATION TOOLS 13
[12] INSTALLATION 13
[13] STRESS DIRECTIONS 15
[14] DISPOSAL 15
[15] ACCEPTANCE REPORT 16
[16] FALL PREVENTION SYSTEM NOTICE 18
[17] INSPECTION REPORT 19
[18] DEVELOPMENT & SALES 21

3
EN
EAP-QUADRAT-10 / Version 170511 / www.innotech.at
2DESCRIPTION OF SYMBOLS
Additional information/notice
Warnings / danger notices
For an IMMEDIATE danger, which could lead to severe injury or death.
ücorrect incorrect
For a POTENTIALLY dangerous situation, which could lead to severe injury
or death.
For a POTENTIALLY dangerou situation, which could lead to injuries and
property damage.
DANGER
WARNING
CAUTION
Follow the manufacturer's instructions / the respective user manuals.
Wear protective gloves!
Wear protective glasses!
Follow the manufacturer's instructions / the respective installation
instructions..

4EAP-QUADRAT-10 / Version 170511 / www.innotech.at
EN
3SAFETY INSTRUCTIONS
3.1 ALLGEMEIN
The following safety instructions and the latest technological standards must be
taken into account.
3.1 GENERAL
- The safety system may only be assembled according to the latest technological
standards and by appropriately trained, competent professionals who are familiar
with the safety system.
- The system may only be installed or used by people who:
- • are trained in the use of PPE (Personal Protective Equipment).
• are physically and psychologically t (health restrictions such as heart and circula-
tory problems, medication, alcohol consumption, etc. reduce user safety.
• are familiar with the locally applicable safety regulations.
- All applicable accident prevention regulations (e.g. for working on roofs) must be
observed during installation / use of the fall prevention system.
- The possibilities, restrictions and risks of using the protective equipment must be
understood and accepted.
- A plan must be available which includes rescue measures for all possible emergen-
cies.
- Before works begin, measures must be taken to ensure that no objects can fall down
from the workspace. The area under the workspace (pavement, etc.) is to be kept
clear.
- The anchor point should be planned, installed and used in such a way that proper
use of the personal protective equipment makes falling over the edge impossible.
(See planning documents at www.innotech.at)
- The positions of the anchor points are to be visibly documented (e.g. witha a sketch
of the rooftop) at the access point to the roof safety system.
- If, after the acceptance of the safety system, renovation work is undertaken in its
immediate vacinity, it must be established that this renovation has no impact on the
safety of the installed safety system! In case of doubt, a structural engineer or the
manufacturer must be consulted.
- After being subjected to the stress of a fall, the entire safety system is to be taken
out of operation and inspected by a qualied professional (component parts, faste-
nings to the substructure, etc.).
- The safety system must not be altered in any way.
- On slanted roofs, the proper snow-catching features must be added to prevent ice or
snow from sliding from the roof surface.

5
EN
EAP-QUADRAT-10 / Version 170511 / www.innotech.at
3SAFETY INSTRUCTIONS
3.2 FOR FITTERS: FOR SAFE INSTALLATION
3.3 FOR USERS: FOR SAFE USE
Should any confusion arise during installation, the manufacturer must
be contacted.
- Alle Edelstahlschrauben sind vor der Montage mit einem geeigneten Schmiermittel
zu schmieren (beigepackt: Weicon AntiSeize ASW 10000 oder gleichwertig).
- Stainless steel may not come into contact with sanding dust or steel tools, as this
can lead to corrosion.
- Proper fastening of the safety system must be documented with fastening reports
and photos of the respective circumstances of installation.
-The tter must ensure that the substructure is appropriate for the fastening of the-
anchoring materials. In case of doubt, consult a structural engineer.
- The roof covering must be sealed according to the appropriate regulations.
- The minimum free space necessary under the edge is calculated as follows: Defor-
mation of the anchor device in case of stress + manufacturer's specication of the
personal protective equipment used, including deection of the cable + body height
+ 1 m safety margin.
- Proper use of the individual components, including the "Personal Protective Equi-
pment" must be ensured, since the eectiveness of the fall prevention system is
otherwise not guaranteed.
- Attachment to the fall protection system is completed with a carabiner and must be
used with personal protective equipment in accordance with EN 361 (safety harness)
and EN 363(fall arrest system).
-ATTENTION! For horizontal use, only such connecting elements can be used which
are designed for this purpose and tested for the respective edge type (sharp edges,
trapezoidal sheet, steel girders, concrete, etc.).
-Do NOT use fall arrest systems if wind speeds exceed normal parameters.
-The fall protection system must NOT be used by children or pregnant women.
- If access to the safety system is granted to external contractors, their familiarity
with this user manual is to be conrmed in writing.
- Should the equipment be sold to a customer abroad, the user manual is to be provi-
ded in the appropriate local language!
- Local lightning protection regulations are to be observed.

6EAP-QUADRAT-10 / Version 170511 / www.innotech.at
EN
4COMPONENTS/MATERIAL
A) Instruction manual
B) Lubricant: Weicon AntiSeize ASW10000
C) INNOTECH standard post: Stainless steel AISI 304
D) Locking nut M16: Stainless steel AISI 304
E) Hex nut M16: Stainless steel AISI 304
F) Anchorage eye: Stainless steel AISI 304
B C
D E F
A

7
EN
EAP-QUADRAT-10 / Version 170511 / www.innotech.at
5PRODUCT APPLICATION/APPROVAL
INNOTECH "EAP-QUADRAT-10" was developed as an anchor point for the personal fall
prevention for 3 persons (including 1 person for rst aid administration) in accordance
with EN 795:2012 & CEN/TS 16415:2013 TYP A, and is suitable for use with the
following fall prevention systems as per EN 363:2008:
- Restraint systems
- Workplace positioning systems
- Fall arrest systems
- Rescue systems
DANGER OF DEATH if used incorrectly.
- Use INNOTECH standard posts ONLY for personal safety.
-NEVER hang loads from INNOTECH standard posts which are NOT appro-
ved of in this instruction manual-
!
DANGER
Follow the manufacturer specications of the personal protective
equipment used.
INNOTECH "EAP-QUADRAT-10" has been tested and certified in accordance with
EN 795:2012 & CEN/TS 16415:2013 TYP A.
The authority notified for type testing:
DEKRA EXAM GmbH, Dinnendahlstr. 9, 44809 Bochum

8EAP-QUADRAT-10 / Version 170511 / www.innotech.at
EN
6.1 INSPECT BEFORE EACH USE
6INSPECTION
Inspection intervals are found in the inspection report.
If there are any doubts concerning the reliable operation of the
fall protection system, it must NOT be used until being checked
by a qualied professional(with written documentation).
If necessary, replace the product.
6.2 ANNUAL INSPECTIONS
INNOTECH standard posts must be inspected at least once annually by a
qualied professional who is familiar with the system. The safety of the user depends
on the eectiveness and durability of the equipment.
Shorter inspection intervals may be necessary, depending on the intensity and
environment of use (e.g. in a corrosive atmosphere, etc.).
Document the inspection by the qualied professional in the inspection report
included in the instruction manual and keep it on record with the manual..
DANGER OF DEATH if the INNOTECH standard post is damaged.
- The INNOTECH standard post must be in faultless condition.
- Do NOT use the INNOTECH standard post if:
• damage or wear on the components is visible.
• any other defects have been observed (loose screw connections, defor-
mations, corrosion, wear, defective roof seals).
• strain has occurred due to a fall
(exception: rst aid administration).
• the product designation is illegible.
!
DANGER
INNOTECH standard posts must be checked visually before each use for any obvious
defects.
Check the entire fall protection system's suitability for use with the help of the acceptan-
ce and inspection reports.

9
EN
EAP-QUADRAT-10 / Version 170511 / www.innotech.at
7WARRANTY
The warranty period for manufacturing defects on all components (under normal
conditions of use) is 2 years from the date of purchase. The term is shortened if they
are used in corrosive atmospheres.
If there is a strain (fall, weight of snow, etc.) the warranty claim is void for those
components that have been designed to absorb energy or that may have been
deformed.
For system installation and for components planned and installed
under the responsibility of specialised professional installation
companies, INNOTECH neither assumes responsibility nor is it bound
by warranty in the case of improper installation.
8SIGNS & MARKINGS
A) Name or logo of the manufacturer/seller: INNOTECH
B) Type designation: EAP-QUADRAT-10
C) Sign that the instruction manual must be
followed:
D) Maximum number of people who can be secured: 3 (including 1 person for
rst aid administration)
E) Year of manufacture and manufacturer's
serial number: YYYY-..-...
F) Number of the applicable norm: EN 795:2012 &
CEN/TS 16415:2013 TYP A
Q
U
A
D
R
A
T
-
1
0
-
X
X
X
J
J
J
J
-
.
.
-
.
.
.
E
N
7
9
5
:
2
0
1
2
T
Y
P
A
max.
A B
C
D
E F
C

10 EAP-QUADRAT-10 / Version 170511 / www.innotech.at
EN
[mm]
9DIMENSIONS
Standard lengths (L): 300/400/500/600 mm
(special lengths available upon request)
120
q
150
q
5
4 x Ø15
16O
L
Inhaltsverzeichnis
Andere Innotech Sicherheitssensor Handbücher

Innotech
Innotech BEF 401-12 Bedienungsanleitung

Innotech
Innotech FAS 01 Bedienungs- und Wartungshandbuch

Innotech
Innotech AIO-ENDS-10 Bedienungsanleitung

Innotech
Innotech Vaisala WXT Bedienungsanleitung

Innotech
Innotech FSG 01 Bedienungsanleitung

Innotech
Innotech QUADRAT-11 Bedienungsanleitung

Innotech
Innotech SENW51 Bedienungsanleitung

Innotech
Innotech AIO-GLEIT-12 Bedienungsanleitung