Boiler controller KXD are modern microcontroller based devices, produced in digital SMT
technology.
KXD controllers are intended for boiler control of direct and/or mixing heating circuit or two
mixing heating circuits and d. h. w. warming with boiler, solar collectors and other energy
sources. KXD controllers also incorporate safety temperature limiter STB for emergency
boiler shutdown.
INTRODUCTION
For initial setup see Initial controller setup, page 9!

6
ENG
CONTENTS
Introduction..................................................................................................................... 5
USER MANUAL
Controller description...................................................................................................... 8
Initial controller setup...................................................................................................... 9
Keypad and other keys................................................................................................... 12
Safety temperature limiter STB ...................................................................................... 12
Graphic LCD display....................................................................................................... 13
Description and presentation of the basic screen: ................................................ 13
Description of symbols presented on the display ........................................................... 14
Symbols for heating circuits .................................................................................. 14
Symbols for operation mode indication ................................................................. 14
Symbols for user functions .................................................................................... 14
Symbols for indication of temperatures and other data......................................... 15
Symbols for protection functions ........................................................................... 17
Symbols for the indication of communication between devices ............................ 18
Symbols for messages and warnings.................................................................... 19
Help, messages and warnings screen............................................................................ 19
Entering and navigating through the menu..................................................................... 20
Menu structure and description ...................................................................................... 20
Temperature settings............................................................................................. 25
User functions ....................................................................................................... 26
Operation mode selection ..................................................................................... 28
Time program settings........................................................................................... 30
Basic settings ........................................................................................................ 32
Data overview........................................................................................................ 34
SERVICE SETTINGS MANUAL
Controller parameters..................................................................................................... 35
User parameters.................................................................................................... 35
Heating curve ........................................................................................................ 39
Service parameters ............................................................................................... 41
.................................................................................... 53
default settings ...................................................................................................... 54
Mixing heating circuit............................................................................................. 55
Basic operation descriptions........................................................................................... 55
Direct heating circuit.............................................................................................. 56
Liquid fuel boiler .................................................................................................... 56
Solid fuel boiler...................................................................................................... 57

7
ENG
Heat accumulator .......................................................................................................57
Control of the heat pump............................................................................................58
Pump for return-pipe temperature increase (bypass pump).......................................58
Domestic hot water.....................................................................................................58
Domestic hot water circulation ...................................................................................60
Remote heating activation..........................................................................................60
Operation of heating systems with two heat sources .................................................60
Setting the minimum RPM for pump R9.....................................................................63
Differential controller ..................................................................................................64
Operation modes in cases of sensor malfunction ......................................................66
INSTALLATION MANUAL
Controller installation...........................................................................................................67
Wall installation...........................................................................................................67
Panel installation ........................................................................................................68
Installation onto boiler ...............................................................................................69
Electric connection of the controller ...........................................................................70
Connection of temperature sensors ...........................................................................71
Room unit DD2+.........................................................................................................72
BUS connection to WXD controllers...........................................................................73
BUS connection to WDC controllers ..........................................................................73
BUS connection to CMP25-2 controllers....................................................................74
Installation and connection of VT safety limiter ..........................................................75
Installation and test of the safety temperature limiter STB.........................................76
Controller malfunction..........................................................................................................77
Sensor simulation and controller operation test .........................................................77
Controller failure and servicing...................................................................................77
Technical data......................................................................................................................78
Declaration of conformity.....................................................................................................79
Disposal of old electrical and electronic equipment.............................................................80
Hydraulic schemes ............................................................................................................159

8
User manual
ENG
1 - USB connector for connecting personal computer.
2 - Graphic display.
3 - Button for emission measurement and STB test.
4 - Keypad
5 - Programmable key
6 - Thermal fuse STB.
7 - Button for activation of controller.
USER MANUAL
CONTROLLER DESCRIPTION
1
2
57
43 6

9User manual
ENG
selection with the button.
In case you chose the wrong language, return to the
language selection with the button.
INITIAL CONTROLLER SETUP
KXD heating controllers are equipped with an innovative solution “Easy start” which ena-
bles the setup of controller in just three or four easy steps.
controller settings is started.
STEP 1 - LANGUAGE SETUP
Use buttons and to select the requested language.
.

10
User manual
ENG
STEP 2 - HYDRAULIC SCHEME SETUP
Select a hydraulic scheme for controller operation.
Move between schemes with buttons and .
.
selection with the button.
In case you choose the wrong scheme, return to
scheme selection with the button.
Later you can change the selected hydraulic scheme with service parameter
S1.1.
STEP 3 - SETUP OF HEATING CURVE STEEPNESS FOR THE FIRST CIRCUIT
circuit.
Change the value with buttons and .
.
-
ing curve steepness with the button.
In case you choose the wrong heating curve steep-
ness, return to heating curve steepness selection
with the button.
Later you can change the heating curve steepness with parameter P2.1. The
meaning of heating curve steepness is detaily described on page 36.
All schemes with mixing heating circuit
wall heating.
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Sprachen: