Technical Information
Model 1000-C 1000-M
Width mm 218 218
Depth mm 465 465
Height mm 440 400
Tap
Clearance
mm 150 150
Power
Rating
KW 3.0 2.25
Rapid
draw-off
Litres 5 3
Weight
(Empty)
KG 8.9 8.4
Weight
(Full)
KG 15.9 14
Water Inlet
Pressure:
Bar 2 to 7 2 to 7 bar
Installation
The boiler must be installed on a level work surface
with sufficient strength to support its weight.
Ensure all vents are unobstructed.
Locate in an area where there is adequate space to
use the boiler safely (e.g. free from risk of congestion
and tripping hazards).
Connection to Mains Water Supply:
Connect the WRAS approved water filling hose
(3/4”BSP) to the inlet connection point on the
back of the boiler and the other end to the mains
water supply, via an accessible isolating tap with
a ¾” BSP thread*.
IMPORTANT: If micro-bore pipe is used instead of
the inlet hose supplied, the size must be minimum
OD 3/8”(10mm).
The water supply must have a pressure not
exceeding 7bar (96psi), and no lower than 2bar
(28psi) NOTE: If your water pressure exceeds 7bar,
fit a suitable pressure reduction valve.
We regret that Instanta cannot be held responsible
for any machine malfunctions if the water pressure
exceeds that stated. If in doubt, consult your water
supply company.
*To meet WRAS installation requirements, an approved
single-check valve providing back-flow prevention
protection, should be fitted at the point of connection
between the water supply and the appliances.
Electrical Connection:
The boiler must be Earthed.
Your machine is supplied with a standard 13amp
bonded plug with a 13amp fuse.
Overflow:
The drip-tray has a limited capacity and is
designed to handle small spillages and drips only.
Wherever possible, we strongly recommend that it
is connected to a permanent waste outlet using the
fitting kit provided.
If preferred, and as an alternative, the overflow-outlet
can be connected from the back of the machine
using an optional rear-overflow kit (Pt. No: ROFK1)
available from Instanta Spares Department (01704
502905).
IMPORTANT: Whichever overflow connection is
chosen, the diameter of the pipe used must be
no less than 15mm.
Failure to connect the overflow-outlet to a
permanent waste or drain, could lead to property
damage from flooding.
If in all circumstances, it is absolutely not possible to
direct the boiler overflow-outlet to a permanent waste
or drain, then the mains water supply to the boiler
should be isolated and the unit switched off whenever
it is left unattended for long periods (e.g. overnight).
Whilst every reasonable precaution is taken to
prevent an overflow, Instanta cannot be held
responsible for any damage caused as a result
of incorrect installation or blockage of the
overflow or failure to direct the overflow to
a safe outlet.
Operation
First Use (once water and electrical connections
have been made):
• Switch boiler on.
• AMBER LIGHT will illuminate to indicate that the
boiler is filling with water.
• Once primed with water, the RED LIGHT will
illuminate to show that it is heating.
• When the boiler reaches the correct
temperature the GREEN LIGHT will show
that the boiler is ready.
4