Intermec MaxiScan 3010 Bedienungsanleitung

Installation Guide
Manual
MaxiScan 3010
Network System
P/N 3-500049-01

2MaxiScan 3010 - Installation Guide – Edition 1.0 draft
Regulatory statements
Intermec hereby declares that the MaxiScan 3010 Network System has been tested and found compliant
with the below listed standards as required by the EMC Directive 89/336/EEC as amended by 92/31/EEC
and by the Low Voltage Directive 73/23/EEC as amended by 93/68/EEC:
EN55022 (1992) EN60950 (1993) EN50082-1 (1997)
USA: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
CANADA: This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du
Canada.
AUSTRALIA-NEW ZEALAND: This equipment has been tested and found to conform to the Australian
EMC framework concerning Class B digital devices, prescribed by the Australian and New-Zealander
standard AS/NZS 3548.
The information contained in this manual is for informational purposes only and is subject to change without notice.
No part of this installation guide may be copied or reproduced in any manner without the prior written permission of
Intermec Technologies Corporation.
© Intermec Technologies Corporation All Rights Reserved
The word Intermec, the Intermec logo, MaxiScan 3010 Network System and EasySet are either trademarks or
registered trademarks of Intermec.
Throughout this manual, trademarked names may be used. Rather than put a trademark (or ) symbol in every
occurrence of a trademarked name, we state that we are using the names only in an editorial fashion, and to the
benefit of the trademark owner, with no intention of infringement.
North America / Asia Pacific / Latin America
6001 36th Avenue West
PO Box 4280
Everett WA 98203-9280
Tel : +1 425 348 2600
Fax : +1 425 348 2833
U.S. service and technical support, tel: 1.800.755.5505
Canadian service and technical support, tel: 1.800.688.7043
Europe / Middle East / Africa
Sovereign House
Vastern Road
Reading RG1 8BT
England
Tel : +44 118 987 9420
Fax : +44 118 987 9416
Internet :
http://www.intermec.com
Email :
Technical support :
http://datacapture.intermec.com
N309

MaxiScan 3010 - Installation Guide 3
Contents
1Introduction...........................................................................5
Warnings
2Installation.............................................................................7
Checklist of items for your installation
Installation considerations
3Connections..........................................................................9
Connections
Network of more than 2 MaxiScan units (with MCS boxes)
Network of 1 or 2 MaxiScan units (without MCS boxes)
4Setup....................................................................................13
Online setup
Offline setup
5System configuration checklist.........................................19
6Technical characteristics...................................................21
7Pinouts.................................................................................23
Scanner bus
Power supply
Host
Synchros
8Intermec scanner bus cables ............................................27
Cable overview
Pinouts

4MaxiScan 3010 - Installation Guide

MaxiScan 3010 - Installation Guide 5
1Introduction
The MaxiScan 3010 Network System (MNS 3010) is a network connection module
designed to connect up a network of up to 20 MaxiScan scanners (MaxiScan
3100, MaxiScan 3300). This Installation Guide explains how to install your MNS
3010 and how to set up a network configuration.
Use the EasySet System setup software to set up the MaxiScan 3010 Network
System.
The MaxiScan 3010 Network System is designed for use with a network of
MaxiScan 3100 and/or MaxiScan 3300 scanners.
In this Installation Guide, unless otherwise specified, "MaxiScan" refers to
MaxiScan 3100 and MaxiScan 3300 and illustrations apply to both products.
Warnings
Do not use a standard MaxiScan power supply connected directly to the
MaxiScan 3010 Network System if you have more than 2 MaxiScan units on
your network—use a power supply suitable for your operating requirements
(see the power calculation method in the Connections section).
Always use a power supply with the earth connected.
Maximum current accepted between the '+' and '–' of the SYNCHROS port is
50 mA max (higher current can damage the synchronization driver !).

1Introduction
6MaxiScan 3010 - Installation Guide

MaxiScan 3010 - Installation Guide 7
2Installation
Checklist of items for your installation
qMaxiScan 3010 Network System connection box
qthis MaxiScan 3010 Network System Installation Guide
qterminator connector - P/N 3-500029-01
Options:
qIntermec Product Information cd-rom with EasySet System Setup software
supporting MaxiScan 3010 Network System - P/N 0-900029-00
qStandard RS-232 C cable (also used to download setup commands from
EasySet) - P/N 0-530022-01
Installation considerations
Environment MaxiScan 3010 Network System complies with IP51
norms. A dry and dust-protected environment is
recommended.
Setup You can use a standard RS-232 cable for MaxiScan to set
up your MaxiScan 3010 Network System with EasySet.
Test your setup before you install the MaxiScan 3010
Network System permanently.
Cabling •Twisted pair for data lines is strongly recommended
on the SCANNER BUS port.
•Depending on cable characteristics (twisted pair,
shield, etc.), an RS-485 connection theoretically
allows a cabling distance of a few hundred meters.
Power supply •Always use a power supply with the earth connected.
•A voltage between 7 and 25 VDC is required (see the
Pinouts section).
MaxiScan 3100 Compatible with all MaxiScan 3100 firmware versions.
MaxiScan 3300 Use MaxiScan 3300 firmware version 1.06 or later.
Configuration with
EasySet Use EasySet software Rev 3.0 (32-bit version) minimum
or Rev 2.0 (16-bit version) minimum with the dedicated
MNS 3010 command file.

2Installation
8MaxiScan 3010 - Installation Guide

MaxiScan 3010 - Installation Guide 9
3Connections
Connections
POWER
SUPPLY SCANNER
BUS
SYNCHROS HOST
input / output
synchronization
power supply
RS-232 C
host
network cable
See the Pinouts and Intermec scanner bus cables sections to make your physical
connections.
How you connect up your MaxiScan 3010 Network System depends on the
number of MaxiScan units in the network and the power rating of the power supply
connected to the MNS 3010.

3Connections
10 MaxiScan 3010 - Installation Guide
Network of more than 2 MaxiScan units (with MCS boxes)
The MaxiScan units are connected to their respective standard MaxiScan
Connexion System (MCS) boxes. All standard MCS boxes are then interconnected
to the MaxiScan 3010 Network System through an RS-485 network bus.
Each MaxiScan has its own power supply and manages its own I/O
synchronization lines.
power supply
MCS
MNS 3010
RS-232 C
RS-485 bus
MaxiScan unit #1
power supply
&
I/O synchrosð
ï
bus termination
ð
MaxiScan unit #n
MCS power supply
&
I/O synchros
Andere Handbücher für MaxiScan 3010
2
Inhaltsverzeichnis
Andere Intermec Steuereinheit Handbücher
Beliebte Steuereinheit Handbücher anderer Marken

Festo
Festo Compact Performance CP-FB6-E Stücklistenhandbuch

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Bedienungsanleitung

JS Automation
JS Automation MPC3034A Bedienungsanleitung

JAUDT
JAUDT SW GII 6406 Series Kurzanleitung

Spektrum
Spektrum Air Module System Bedienungsanleitung

BOC Edwards
BOC Edwards Q Series Bedienungsanleitung