iSysmart ZigBee SGZ805A Bedienungsanleitung

Sysmarti
ZigBeeTM-Power Switch w/ Energy Consumption Monitoring
User Manual
Power Switch Unit
Model: SGZ805A
Energy Consumption Monitoring Series
For Home Automation Network

N
N
L(IN)
L (OUT)
Switch Key
Binding Key
External Switch
Power Switch Unit
SGZ805A
Figure 1: SGZ805A

Product Specification
Fully IEEE 802.15.4 compliant
Utilizes 2.4GHz ISM band, up to 16 channels
100-240VAC, 50/60HZ input power
Resistive load: 16A/250VAC, 4000W
Inductive load: 1½ HP (Horsepower) @240VAC
Up to 150 meters non-obstacle wireless distance
Simple operation and device configuration.
Introduction
SGZ805A is a wireless AC power switch device with power/energy/current/voltage
consumption monitoring feature. In the network, SGZ805A functions as a router device in
the network which permit join other devices to the network. The device can be paired with
a ZigBee enabled on/off remote device to control. ISysmart has its proprietary energy
management system application software to view power or current consumption.
What is ZigBee?
ZigBee is a short range wireless transmission technology which defined for a minimum
complexity, low power consumption, low data rate, cost effective wireless solution. ZigBee
lies in between wireless markup technology and Bluetooth. ZigBee is based on
IEEE802.15.4 standard, the mutual co-ordination between thousands of sensors to
exchange data. Sensor to sensor or node-to-node communication is achieved through
relays of control data between devices with only a fraction of energy use which denoted
for highly transmission efficiency.
Note: Wireless communication, in some real use cases, can be limited by the signal
blockage. Please consult your service provider or place of purchase.
Ambient
Operating
Temp
-10℃~50℃
Operating
Humidity
5%~85%RH
Storage
Temp.
-40℃~85℃

Setting Up Summary
(1)
Startup and network association
Note: when successfully joined, we strongly suggest you to allow 1 minute performing self
calibration on the meter before it is ready to take load. This is particular important for correct
reading.
(2)
Pair the device with other device where applicable (i.e. bind it with a ZigBee switch
for wireless control).
(3)
When it is bind with a controlling device it is then ready to be used.
(4)
Power/current consumption monitoring
Step 1. Startup and Network Association
Setting up the SGZ805A and network
To allow SGZ805A to function, it must first join to a ZigBee network. When it is given
poweredit will automatically start searching for an existed network. So before you give
power to SGZ805A make sure it is within the wireless coverage distance (~150 meters or
less) and make sure first you have the permit-join feature enabled either on a
coordinator or a router device in the network so that SGZ805A will join to the network
through it; then give power to SGZ805A and it will join into the network by itself.
*On how to enable permit-join please refer to the router or coordinator device user manual
Operation:
Step 1: Make sure you have open up permit-join function (valid for 60 seconds) of a
coordinator or a router
Step 2: Now wire the AC cable of SGZ805A to the AC source to power it up. SGZ805A device
willstart to search for the network within reach.
Step 3: When the device found the network, the LED indicator on the SGZ805A will
flash. Anon-flashing solid light indicates successful join otherwise the indicator stays dark.
How to wire the device
Please go to Power Cable Installation section.

SGZ805A can be bound with a ZigBee enabled Home Automation ON/OFF switch
Pairing operation:
1.
On SGZ805A, long press the binding key for 3 seconds. You should see the
LEDflash once then release the key.
2.
Likewise, do the same on the control switch to exchange binding according to the
instructions of that device.
When pairing is successful the LED indicator on SGZ805A flashes 5 times then turn solid lit,
otherwise it flashes 10 times indicating pairing unsuccessful.
Clear pairing setting: You may remove the pairing between the two or more devices.
Unbinding procedure is exactly the same as binding operation. When you repeat the
binding operation, the two devices will remove the binding information stored.
Step 2. Device pairing (binding)

How to use SGZ805A
Wireless control SGZ805A device
A switch control device such as ISysmart Z501 remote controller paired with SGZ805A
may send ON or OFF command, SGZ805A would respond to either turn ON or OFF
accordingly.
Manual switch
Please refer to installing an external switch section of the manual.
Power Consumption Reporting
When the load is attached to the device, the embedded meter reads the supplied current
drawn overtime. SGZ805A reports the readings to a paired target device normally are an
in-home display or consumption data logger. Ensure that you go through consumption
reporting and configure reporting time interval described in Application page otherwise
SGZ805A will not sent consumption reading. SGZ805A can report the consumption
reading to ISysmart’s application or to any 3rd party in-home display.
Power drawn overtime is measured. Current (unit mA), Voltage (unit V), Power (unit W)
and Energy (unit Wh).
Permit other device to join
SGZ805A is featured to be a router in the network. It permits join other devices to the
network.By default the router device SGZ805A does not allow permit-to-join function in
anormal operation to protect the network from unexpected or unauthorized join attempt.
You will need to open up the permit-join on SGZ805A to allow new devices (a router or an
end device)to join.
Operation:
1.
On SGZ805A, short press the binding key once
2.
The permit join is now enabled for 60 seconds and the indicator light will blink for 60
times.
3.
SGZ805A waits the new device to join automatically. Please note that the maximum
waiting time to join is 60 seconds. Repeat the process if you missed the 60 seconds
period.
4.
SGZ805A allows 14 devices maximum to join as its sub-devices.

Restore to factory setting
SGZ805A is capable of storing and saving includes network routing information. If you
wish to remove SGZ805A from an exited network, you would need to clear the saved
routing information to join to a new network by simply reset the device to restore to the
factory setting.
Operation:
1.
Hold press the binding key for more than 15 seconds until you see the indicator give 4
timely flashes (flashes twice for the first, once on the 3rd second, and once on the 10th
second) then the indicator will start flash quickly for 20 seconds. You may release the
key.
Now the device has restored to the factory setting.
2.
Within this 20 seconds, press the binding key again to force device reboot. Soon the
device will enter network search mode to attempt to join to a network. (Refer to Network
Association section of the manual)
Overload Protection
When load surpasses 20A, less than 30 seconds SGZ805 will switch off current supply.
When load is between 18A to 20A, less than 60 seconds the current will be switched off.
When load is between 16A to 18A, less than 120 seconds the current will be switched off.

Summary of Key function and corresponding display
Function
Key & Display
Restore to factory
setting
Hold press binding key more than 15s
4 timely flashes.
When the LED flash becomes quickly release the,
press again to reboot the device.
Permit Join
Short press binding key once.
Flashes 60 times in 60 seconds.
Device Pairing
Hold press binding key 3s. Flash once.
Flash 5 times: successful
Flashes quickly 10 times unsuccessful

L (out) L (in)
N_1 N_2
L (out) L (in)
N
Power Cable Installation
From Figure 1, there are 2 neutral wires. In real current circuit, these 2 neutral wires are
actually one. So you may see it as depicted in Figure 2. We provide an extra neutral wire
for your installation convenience. Load wiring schematic is shown in Figure 3 and 4.
Figure 1 Figure 2
AC input plug
Or wiring
AC input plug
Or wiring
or
Figure 3
Load
(fan, lights)
Figure 4
Load
(fan, lights)
L (out) L (in)
N_1 N_2
L (out) L (in)
N_1 N_2

We strongly suggest you to disconnect power source before
connecting the external switch.
Installing an External Switch
Other than being a wireless power switch, SGZ805A is given external switch connectors
toenable conventional switch to be attached. Choose a normally open switch to connect.
You may use any range of current rating of the switch, as the switch cable does not run
load current but switch signal change.
Inhaltsverzeichnis

















