Italkero faro Service-Handbuch


2GENERAL
COMPLIANCE
Our appliance are compliance at:
Gas directive 90/396/CEE
Electromagnetic directive compatible 89/336/CEE
Low-tension directive 73/23/CEE 0694
RANGE
Faro
MODEL CODE
FR70R2 M0000

Kind Technical
We thank you for choosing the appliance. We can assure you its performance will be long lasting,
reliable when it is installed and used properly (manufacturerʼs guidelines are followed).
Good work and thanks
The Manufacturer.
3
GENERAL
WARRANTY
Provided that it is fitted in accordance with the Manufacturer's instructions, this
appliance benefits from the statutory warranty.

GENERAL
General informations pag.5
Safety rules pag.5
Appliance description pag.6
Identification pag.6
Structure pag.7
Technical data pag.8
Accessories pag.8
Electrical scheme pag.9
Control panel pag.10
INSTALLATION
Receiving the product pag.11
Installation types pag.12
Weight and dimension pag.12
Installation pag.13
- Apparatus choice location pag.13
- Intake and exhaust tube fumes assemblage pag.14
- Fastening the appliance pag.15
- Fitting and removing the front and rear panel pag.17
- Ø 54 mm parallel pipes with single end piece pag.18
- Fitting Special pipe KIT from inside the premises to be heated pag.19
- Ø 54 mm pipes with single end piece pag.19
- Diaphragms assemblage pag.23
- Fitting the remote digital control pag.24
Electrical collegaments pag.25
Gas connection pag.26
CUSTOMER SERVICE
Preliminary operations pag.25
First service start pag.25
Processor control box malfunction pag.26
Controls during the first & after starting service pag.26
Gas transformation pag.27
Regolation pag.28
Ordinary maintenance pag.29
Appliance clean out pag.29
Components replacement pag.30
Disassembly & reassembly of the skirt pag.34
Eventual anomalies & remedies pag.34
Useful information pag.36
4GENERAL
In same parts of the book there are used these symbols:
Attention: it used to underline particular caution or actions.
Prohibited: it used to underline the actions that don’t half to
be executed.
INDEX

We like to remember that, products that use combustion
or electrical energy there is security rule to observe
before operating.
Do not allow children to be near the appliance.
It is prohibited to turn on an electrical device if there
is a gas smell.
In this case:
- Open windows and door.
- Close the gas tap.
- Call a Technical Service Assistance.
It is prohibited to touch the appliance with wet hand
or other parts of your body.
-Electrical Hazard: Do not touch the appliance with
wet feet or other part of your body.
It is prohibited to clean the appliance when it is run-
ning.
It is prohibited to pull, remove and wring electric
wires outside the appliance also if the electrical
supply is turned off.
It is prohibited place over the appliance, towels, tea
clothes and other could be cause of inefficiency or
also source of hazard.
It is prohibited to leave paper, plastic, or other things
of the appliance box outside within a childʼs reach.
After removing the packaging, check the integrity of
the contents. In case of discrepancies, contact the
Agency that sold the appliance.
The appliance must be installed by an authorised
company pursuant to Law no. 46 dated 5 March
1990. After installation, such company should issue
the owner with a declaration of conformity of proper
installation, according to current national regulations
and any local regulations pursuant to Art. 17 of law
no. 46/90 and the instructions provided by the
Manufacturer in the installer's booklet that accompa-
nies the product.
The appliance must be used as intended by the
Manufacturer and for the purpose for which it was
expressly built.
The Manufacturer disclaims any contractual and
non-contractual liability for injury to persons and ani-
mals and damage to things caused by installation,
adjustment and maintenance errors or improper
appliance use.
If the appliance is not used for a long period of time,
the following operations will have to be performed:
- position the master switch of the appliance on
"OFF"
- position the master switch of the system, if fitted, on
"OFF" or disconnect the plug from the power socket.
- close the gas tap
The appliance should be serviced at least once a
year.
This booklet is an integral part of the appliance and
must therefore be carefully looked after and
ALWAYS accompany the appliance, including when
this is sold to another user or transferred to another
system.
In case of damage or loss, ask the Area After Sales
service of the Manufacturer for another copy.
Always make sure that curtains or other objects do
not obstruct the suction filter and the room air outlet
vent.
Only connect the appliance to properly earthed
power sockets.
Only install the appliance in dry environments (pro-
tection IP 20)
The appliance must not be operated wherever there
are hazardous materials, vapours or liquids.
Install the appliance on a flat surface to prevent any
malfunction.
5
GENERAL
GENERAL INFORMATIONS
SAFETY RULES

The appliance is identified through:
- Packed label:
A label that indicates the code and the combustion it
uses to identifies the appliance.
- Technical label:
The technical label reports the matrices numbers,
the gas prearrangement, and technical observation.
-Gas prearrangement label:
It reports the kind of gas the appliance has to use,
and if there is a transformation from one kind of gas
to another you have to change the old label.
Spare parts, or technical operation require, a
precise identification of the type of model.
If there is going to be any tampering of the technical
label, this will not consent the right identification of
the apparatus.
The appliance is a gas radiator that heat up the
atmosphere.
It has an intake of air that goes in the combustion
chamber type C.
The appliance is made with an aluminium body that
allows a high efficiency of heat; it also has a fan that
allows the dispersal of air faster in the rooms.
The appliance are arranged in factory for the function
at gas methane and they can be transformed to
GPL(G30/G31) using the furnished nozzle kit.
Note: At request the appliance can be furnished
already arranged at GPL.
It also has an electrical device that allows you to do
a series of things.
There also is a Processor Control Box (P.C.B
assy) that controls all the principalsʼfunction of
the apparatus.
After there is the Control Panel that has other
options.
6GENERAL
APPLIANCE DESCRIPTION
IDENTIFICATION
Metano
Methane
G.P.L.
L.P.G.

7
GENERAL
STRUCTURE
19
21
1 Fume exhaust
2 Air intake pipe
3 Convection fan
Condenser
5 Safety thermostat
6 Structure
7 Heat exchanger
8 Glass pipe
9 Ignition electrode
10 Detection electrode
11 Pressure switch
12 Combustion chamber
13 Combustion fan
1 Garter spring
15 Power plug
16 Technical data plate
17 Gas valve
18 Gas tap
19 Manual control
20 Control unit
21 On/Off switch
22 Thermostat knob
23 On/Off Wireless key
2 Wireless Control
25 Room heat probe
26 Data setting keys
27 Display screen
1 2
3
5
6
7
8
12
13
1
17
18
11
15
16
10
9
19 20
22 23
@
25
27
26
2

The following options are available upon request:
8GENERAL
MODEL
kW
kW
%
mbar
m3/h
kg/h
n∞
Ø
m3
m3/h
V~Hz
W
kg
kW
kW
kW
kW
mbar
faro
6,5
90,7
C13 - C33 - C53 - C63
II
2H 3+
1
3
230~50
135
IP20
5,9
,8
,3
LPG
28,5/36,3
0,511/0,276
0,7
1 3 ∏ 86
228
17/21
Methane
12,0
0,587/0,3 5
1,30
1 3 ∏ 86
228
58
7,5
Methane
G30
G31 kg/h
0,50 /0,273
mbar
29/3720
Terminal capacity nomination (Qn)
Right efficiency
Nozzle pressure
Gas consumption (15∞C) (nom./red.)
Type of apparatus
Combustion category
Efficiency class
Nozzle
Max/min value Atmospheric
heated by a convector
Quantity of air heated
Electrical alimentation
Power absorbed when in function
Protection degree
Weight with the convector in box
Terminal capacity reduction (Qn)
Terminal power convector nomination (Pn)
Terminal power convector reduction (Pn)
Reduce nozzle pressure
Main pressure (nomination)
DESCRIPTION CODE
90∞ curve _Ø 5 mm pipe union
Extension Ø 5 mm L = 500mm
Extension Ø 5 mm L = 1000mm
90∞ curve Ø 5 mm cast
Outer protection grille "GP" for separate end piece Ø 5 mm
Recessed screen "SDP" for separate end piece Ø 5 mm
Stack for pipe Ø 5 mm
INSULATION for pipe Ø 5 mm L = 1000mm (pack of pcs.)
Inlet/Outlet end piece Ø 5 mm L = 6 cm
135∞ curves Ø 5 mm
Outer protection grille "GPu" for combined end piece Ø 5 mm
70000370 00
70000390 00
70000380 00
70000755 00
70000350 00
70000365 00
700007 0 00
70000850 00
70000 65 00
70000375 00
70000610 00
Base + Side support foot 70000 95 00
TECHNICAL DATA
ACCESSORIES

9
GENERAL
ELECTRICAL SCHEME
CN1
3 2 1
CN2
1 2
CN6
3 2 1
VC
CN8
1 2 3 4 5 6
CN7
1 2
CN5
1
2
EV2
4
3
SAS
PS
F 1AT 250V
TL
LN
CL
230V~
EV1
EP
T1
ER
TA
3 2 1
EA
CN
MIN
MAX
C
SC II I O
V.T.C.
CVT
SAS
VC
VT
CN...
T1
VT
TA
BL
WH
R
SC
EA
ER
EV1
F
CL
EV2
L
N
PS
TL
EP
CVT
SPLIT ROOM PROBE
COMBUSTION FAN
TANGENTIAL FAN
CONNECTOR
POWER TERMINAL
TANGENTIAL FAN
IGNITION TRANSFORMER
BLUE WIRE
WHITE WIRE
RED WIRE
CONTROL BOARD
IGNITION ELECTRODE
DETECTION ELECTRODE
ELECTRIC GAS VALVE
FUSE
LINE CONNECTOR
POWER MODULATOR
PHASE LINE
NEUTRAL LINE
PRESSURE SWITCH
High LIMIT THERMOSTAT
EASY PANEL
TANG. FAN CONDENSER

10 GENERAL
CONTROL PANEL
1 - GREEN Led On = heater On
1b - GREEN Led Off = heater Off
2 - RED Led On = burner flame block
2b - RED Led Off = heater released
2c - RED Led SLOW flashing = pressure switch donʼt switch ON
2d - RED Led FAST flashing = locked pressure switch
3 - Thermostat knob regulation (approximate value): from MIN 5°C to MAX 35°C
A = from 5°C to 10°C
B = from 11°C to 16°C
C = from 17°C to 22°C
D = from 23°C to 28°C
E = from 29°C to 35°C
4 - GREEN Led On = Wireless control panel activated
4b - GREEN Led Off = Wireless control panel disabled
4c - GREEN Led flashing = waiting to recognize the Wireless
4d - GREEN Led flashing = Wireless default transmission (about. 2,5 minutes)
4e - GREEN Led flashing = Wireless data transmission by the change of any parameter
5 - Wireless On button switch = press and hold 2 seconds, LED 4 starts to blink to recognize the Wireless
(waiting at MAX 60 seconds) after which it automatically reactivates the manual control
5b - Wireless Off button switch = press and hold 2 seconds, LED 4 turns off automatically activating the
manual controls
6 - YELLOW Led FAST flashing = flame ignition cycle: start
6b - YELLOW Led SLOW flashing = burner ON turned to MIN heating
6c - YELLOW Led On = burner ON turned to MAX heating
6d - YELLOW Led Off = burner off, temperature reached
7 - Heater On/Off button switch
7b - RESET button switch = when switch On again, the Heater restart automatically
1 2 3 4
567
A
B
C
D
E
Inhaltsverzeichnis
Andere Italkero Heizung Handbücher
Beliebte Heizung Handbücher anderer Marken

Empire Heating Systems
Empire Heating Systems WCC65 Bedienungsanleitung

Wetekom
Wetekom 92 86 43 Bedienungsanleitung

Desa
Desa SPC170-F Bedienungsanleitung

Watlow
Watlow Watrod Electric Tubular Heaters Bedienungsanleitung

Haverland
Haverland ECO-DRY GPS Series Stücklistenhandbuch

Stelpro
Stelpro ASILVC2060 Series Bedienungsanleitung