ITT Engineered Valves Advantage 2.1 8 Series Bedienungsanleitung

Installation and Operation
Manual
Advantage® 2.1 Actuator


Table of Contents
1 Introduction and Safety ....................................................................................................................................2
1.1 Safety message levels .............................................................................................................................. 2
1.2 User health and safety .............................................................................................................................. 2
2 Transportation and storage..............................................................................................................................4
2.1 Handling and unpacking guidelines........................................................................................................... 4
2.2 Storage, disposal, and return requirements ..............................................................................................4
3 Product Description ..........................................................................................................................................5
3.1 Actuator identification ................................................................................................................................ 5
3.2 Bonnet description..................................................................................................................................... 6
3.3 Valve diaphragm identification................................................................................................................... 7
4 Installation..........................................................................................................................................................8
4.1 Precautions ............................................................................................................................................... 8
4.2 Install the valve and topworks ...................................................................................................................8
4.3 Change the compressor, tube nut, and snap ring ..................................................................................... 9
4.4 Mount the topworks to the valve.............................................................................................................. 10
4.5 Tighten the bonnet fasteners...................................................................................................................10
4.6 Fastener torque table for valve body to topworks ................................................................................... 11
4.7 Actuator operating pressure .................................................................................................................... 11
4.8 Set the adjustable opening stop .............................................................................................................. 11
4.9 Disassemble the valve ............................................................................................................................ 12
4.10 Replace the valve diaphragm................................................................................................................12
Table of Contents
Advantage® 2.1 Actuator Installation and Operation Manual 1

1 Introduction and Safety
1.1 Safety message levels
Definitions
Safety message level Indication
DANGER:
A hazardous situation which, if not avoided, will result in death or
serious injury
WARNING:
A hazardous situation which, if not avoided, could result in death
or serious injury
CAUTION:
A hazardous situation which, if not avoided, could result in minor
or moderate injury
ELECTRICAL
HAZARD:
The possibility of electrical risks if instructions are not followed in a
proper manner
NOTICE:
• A potential situation which, if not avoided, could result in an
undesirable result or state
•A practice not related to personal injury
1.2 User health and safety
General precautions
This product is designed and manufactured using good workmanship and materials, and meets all appli-
cable industry standards. This product should be used only as recommended by ITT or ASCO.
WARNING:
•Misapplication of the valve can result in injury or property damage. Select valves and
valve components of the proper materials and make sure that they are consistent with
your specific performance requirements. Incorrect application of this product includes but
is not limited to:
• Exceeding the pressure or temperature rating
• Failing to maintain this product according to the recommendations
• Using this product to contain or control media that is incompatible with the materials
of construction
Qualifications and training
The personnel responsible for the assembly, operation, inspection, and maintenance of the valve must
be appropriately qualified. The operating company must do the following tasks:
• Define the responsibilities and competency of all personnel handling this equipment.
• Provide instruction and training.
1 Introduction and Safety
2 Advantage® 2.1 Actuator Installation and Operation Manual

• Ensure that the contents of the operating instructions have been fully understood by the personnel.
Instruction and training can be carried out by either ITT or the reseller of the valve by order of the operat-
ing companyASCO as the reseller of the valve by order of the manufacturer.
Non-compliance risks
Failure to comply with all safety precautions can result in the following conditions:
• Death or serious injury due to electrical, mechanical, and chemical influences
• Environmental damage due to the leakage of dangerous materials
• Product damage
• Property damage
• Loss of all claims for damages
Operational safety precautions
Be aware of these safety precautions when operating this product:
• Do not leave hot or cold components of the product unsecured against contact if they are a source
of danger.
• Do not remove the contact guard for moving parts when the product is in operation. Never operate
the product without the contact guard installed.
• Do not hang items from the product. Any accessories must be firmly or permanently attached.
• Do not use the product as a step or hand hold.
• Do not paint over the identification tag, warnings, notices, or other identification marks associated
with the product.
Maintenance safety precautions
Be aware of these safety precautions when performing maintenance on this product:
• You must decontaminate the product if it has been exposed to harmful substances such as caustic
chemicals.
Use of unauthorized parts
Reconstruction or modification of the product is only permissible after consultation with ITT. Genuine
spare parts and accessories authorized by ITT serve to maintain safety. Use of non-genuine ITT parts
can annul liability of the manufacturer for the consequences. ITT parts are not to be used in conjunction
with products not supplied by ITT as this improper use can annul all liability for the consequences.
Unacceptable modes of operation
The operational reliability of this product is only guaranteed when it is used as designated. The operating
limits given on the identification tag and in the data sheet may not be exceeded under any circumstan-
ces. If the identification tag is missing or worn, contact ITTASCO for specific instructions.
NOTICE:
ISP employs a magnet to indicate valve position. Other than the calibration/solenoid dongle,
avoid placing magnets on or around the ISP
. Such magnets may erroneously modify the posi-
tion indication.
1.2 User health and safety
Advantage® 2.1 Actuator Installation and Operation Manual 3

2 Transportation and storage
2.1 Handling and unpacking guidelines
CAUTION:
Always observe the applicable standards and regulations regarding the prevention of accidents
when handling the product.
Handling guidelines
Follow these guidelines when handling the product to prevent damage:
•Use care when handling the product.
• Leave protective caps and covers on the product until installation.
Unpacking guidelines
Follow these guidelines when unpacking the product:
1. Inspect the package for damaged or missing items upon delivery.
2. Note any damaged or missing items on the receipt and freight bill.
3. Do not lift or pull on the electrical conduit lines. Doing so may cause the POC switches to come
out of calibration.
2.2 Storage, disposal, and return requirements
Storage
If you are not immediately installing the product after delivery, store it as follows:
• Store the product in a dry room that maintains a constant temperature.
• Make sure that the products are not stacked on top of one another.
Disposal
Dispose of this product and associated components in compliance with federal, state, and local regula-
tions.
Return
Ensure these requirements are met before you return a product to ITTASCO:
• Contact ITTASCO for specific instructions on how to return the product.
• Clean the valve of all hazardous material.
• Complete a Material Safety Data Sheet or Process Data Sheet for any process fluid that could re-
main on the valve.
• Obtain a Return Material Authorization from the factory.
2 Transportation and storage
4 Advantage® 2.1 Actuator Installation and Operation Manual

3 Product Description
3.1 Actuator identification
Design Overview
The actuator is a spring or double acting pneumatic actuator.
To determine if you have an Advantage actuator or an Advantage actuator 2.1 locate the spindle com-
pressor connection and determine if you have a pin connection or modular compressor design.
Figure 1: Pin connection for Advant-
age actuator
Figure 2: Compressor
for Advantage 2.0 ac-
tuator
Figure 3: Modular compressor
with snap ring retention for Ad-
vantage 2.1 actuator
Model number
The actuator model number is located on the ITTASCO identification tag. The model number is a four
digit number defining the actuator as follows.
Table 1: Actuator
Code Description
B Advantage 2.1 actuator
Table 2: Mode of operation
Code Description
1 Fail open (spring to open, air to close) (direct acting)
2 Fail close (spring to close, air to open) (reverse acting)
3 Double acting (air to open, air to close)
Table 3: Actuator series
Code*1 Actuator series*2
03, 04 3
05, 06 5
08, 09 8
16, 17 16
*1 For fail close actuators, codes are specific spring combinations.
*2 Series number equates to diaphragm effective area.
3 Product Description
Advantage® 2.1 Actuator Installation and Operation Manual 5

Table 4: Examples
Model number Description
B308 Advantage 2.1 actuator, double acting, series 8
B216 Advantage 2.1 actuator, fail close, series 16 with a spring set
Identification tag
Line Description
1 Valve serial number
2 Valve size and model number
3 Valve diaphragm type
4 Maximum recommended actuation pressure
3.2 Bonnet description
Non-Sealed bonnet
The non-sealed bonnet has a weep hole that indicates a diaphragm failure by allowing process fluid that
accumulates in the bonnet to pass through the hole.
Sealed bonnet
The sealed bonnet uses a special “V-notch” vent plug, which permits leak detection.
Bonnet
weep hole
V-notch vent plug
(Sealed bonnet only)
Figure 4: Weep hole and V-notch vent plug
3.2 Bonnet description
6 Advantage® 2.1 Actuator Installation and Operation Manual

3.3 Valve diaphragm identification
Diaphragm tab codes
All diaphragm materials and physical properties are batch traceable via permanent codes molded into
the diaphragm tabs. The molding date, grade of diaphragm, and size provide traceability to original batch
records.
1. Date code
2. Supplier code
Figure 5: Elastomer diaphragm front
1. Valve size
2. Grade of diaphragm
Figure 6: Elastomer diaphragm back
1. Material code
2. Date code
Figure 7: PTFE diaphragm
3.3 Valve diaphragm identification
Advantage® 2.1 Actuator Installation and Operation Manual 7

4 Installation
4.1 Precautions
WARNING:
•All procedures must be performed by qualified personnel.
• When the process fluid is hazardous, thermal (hot or cold), or corrosive, take extra pre-
cautions. Employ the appropriate safety devices and be prepared to control a process
media leak.
• Always wear protective clothing and equipment to safeguard the eyes, face, hands, skin,
and lungs from the fluid in the line.
• Do not disassemble the actuator in the field. The actuator contains energized springs
which can cause injury. The product is designed to be recycled in its entirety.
CAUTION:
•Disconnect electrical, pneumatic, and hydraulic power before servicing actuator or auto-
mation components.
4.2 Install the valve and topworks
NOTICE:
The topworks size and configuration can limit the actual operating pressure. Consult the Pure-
Flo catalog for pressure limitations. Consult the factory or engineering catalog for vacuum op-
eration.
Consider the following information before installing the actuator:
•The series 3, 5, 8, or 16 stainless steel bonnet Advantage 2.1 actuator can have the air inlets posi-
tioned in any quadrant.
• The maximum valve operating pressure is 10.34 bar | 150 psig. This pressure is applicable up to
38ºC | 100ºF. Valves at maximum pressure cannot be used at maximum temperatures.
• The maximum actuator pressure is 6.2 bar | 90 psi.
1. If you have a weld end valve, then consider the following:
If you are welding ... Then ...
Manually Remove the topworks.
In line for schedule 10 or heavi-
er pipe
Remove the topworks.
In line for schedule 5 or lighter
pipe and tubing
You can weld with automatic equipment. Before you perform the
weld:
1. Remove the topworks (optional).
2. If left installed, set the valve to the open position.
3. Properly purge the valve with an inert gas.
2. Install the valve.
4 Installation
8 Advantage® 2.1 Actuator Installation and Operation Manual
Dieses Handbuch passt für folgende Modelle
3
Inhaltsverzeichnis
Andere ITT Controller Handbücher

ITT
ITT GFH45 Gebrauchsanweisung

ITT
ITT Conoflow GB50 Series Gebrauchsanweisung

ITT
ITT Engineered Valves Advantage 2.1 Bedienungsanleitung

ITT
ITT Bell & Gossett ZoneTrol II Z-2 Handbuch

ITT
ITT GFH20XT1767C Gebrauchsanweisung

ITT
ITT Conoflow HP400 Gebrauchsanweisung

ITT
ITT Advantage 2.0 Bedienungsanleitung

ITT
ITT Hydrovar Montage- und Bedienungsanleitung

ITT
ITT Lowara GENYO 16A / R15-25 Bedienungsanleitung

ITT
ITT Bell & Gossett ZoneTrol II Z-1 Handbuch