Important Safety Information
The use of improper input voltage may result in poor perfor-
mance or damage to the ionizer. This will void the warranty! For
safety, the use of extension cords is not recommended.
Do not use this Blower in an explosive environment. Poorly
maintained Ionizers could produce miniscule electric arcs at the
emitter points. This may cause detonation in an explosive envi-
ronment. Read the Power Requirements section in Chapter 1
and the Operating Environment section below in this chapter
before applying power to the unit.
Make sure the power switch is set to OFF on the Control Box
before connecting or disconnecting the CAT-5 cable between
the Fan Unit and the Control Box.
To avoid personal injury or damage to the equipment, do not
perform any maintenance other than that contained in these
instructions.
There are no user-serviceable parts inside this Blower other
than emitter points. Any unauthorized service will void the
warranty and may result in additional repair charges.
Before performing any of the following maintenance, be sure
the Model 5802i is powered off and unplugged.
Carefully read the following safety information before
installing or operating the equipment. Failure to follow
these safety warnings could result in damage to your
ionization system and/or voiding the product warranty.

19-5802i-M-02 Rev 4
Informations de Sécurité Importantes
Ne pas utiliser ce ventilateur dans un environnement explosif.
Mal entretenu ioniseurs pourrait produire infime arcs élec-
triques au points émetteurs. Cela peut provoquer de la détona-
tion dans un environnement explosif. Lire la puissance requise
du chapitre 1 et de l'environnement d'exploitation section ci-
dessous dans ce chapitre avant d'appliquer la tension à l'unité.
Assurez-vous que l'interrupteur d'alimentation est réglé sur
OFF sur le boîtier de commande avant de connecter ou de
déconnecter le câble CAT-5 entre l'unité du ventilateur et le
boîtier de commande.
Pour éviter tout risque de blessure ou de détérioration du
matériel, n'effectuez aucune opération d'entretien autres que
celles contenues dans ces instructions.
Il n'y a aucune pièce réparable par l'utilisateur cette soufflerie
autres que points émetteurs. Tout service non autorisé
annulera la garantie et peut entraîner des charges de répara-
tion.
Avant d'effectuer toute la maintenance suivante, s'assurer que
le modèle 5802i est hors tension et débranchée.
.
L'utilisation d'une mauvaise tension d'entrée peut
entraîner une mauvaise perfor-mance ou
d'endommager l'ioniseur. Ceci annule la garantie. Pour
des raisons de sécurité, l'utilisation de cordons
d'extension n'est pas recommandée.

19-5802i-M-02 Rev 4
Contents
1 Description .......................................................................... 1
1.1 Critical Environment Ionizing Blower Model 5802i................................... 2
1.2 Blower Features....................................................................................... 3
1.3 Blower Options......................................................................................... 4
1.4 External Sensor Option............................................................................ 5
1.5 Performance ............................................................................................ 6
1.6 Power Requirements ............................................................................... 7
2 Installation & Setup............................................................. 9
2.1 Tilt Lock Mounting Stand ....................................................................... 10
2.2 Cord Lock Installation Option................................................................. 11
2.3 Cord Clamp Installation.......................................................................... 12
2.4 Ground Jack Use ................................................................................... 13
2.5 Sensor Connections & Setup Option ..................................................... 14
2.6 FMS Connection Option......................................................................... 19
3 Operation ........................................................................... 21
3.1 Operating Environment.......................................................................... 22
3.2 Turning on the Blower............................................................................ 23
3.3 Balance Adjustment............................................................................... 24
3.4 Optional Sensor Operation .................................................................... 26
3.5 Alarms.................................................................................................... 28
4 Maintenance ...................................................................... 29
4.1 Maintenance Scheduling........................................................................ 30
4.2 Emitter Point Inspection & Cleaning ...................................................... 31
4.3 Using the Auto-Clean System Option .................................................... 32
4.4 Emitter Ring Cleaning............................................................................ 33
4.5 Fan & Finger Guard Cleaning................................................................ 34
4.6 Chassis Cleaning................................................................................... 35
4.7 Troubleshooting ..................................................................................... 36
5 Specifications.................................................................... 37
6 Warranty & Service ........................................................... 41

19-5802i-M-02 Rev 4 2
1.1 Critical Environment Ionizing Blower
Model 5802i
The Critical Environment Ionizing Blower Model 5802i is a fast and
reliable ionizing Blower for controlling static charge in desktop work
areas and small spaces in critical areas. The Model 5802i achieves
an offset balance of ±3V or better than ±1V offset balance with an
optional external sensor connected. With the sensor input option,
the Blower automatically corrects balance so that ionization is
continued to be accurately delivered to your target.
Figure 1. Ionizing Blower Model 5802i
This manual describes the features of the Blower and procedures
for installation, operation, and maintenance.

19-5802i-M-02 Rev 4 3
1.2 Blower Features
The Model 5802i is offered in an epoxy-polyester powder-coated
aluminum or plain finish stainless steel chassis. Several other
feature configurations are available to suit your environment.
Controls and connectors are located on the back of the Blower. The
following features are standard, as shown below:
1. Balance Adjust: Trimpot adjusts positive and negative ion
output.
2. Ground Jack: A standard banana-jack connection for optional
grounding of blower or test equipment.
3. Power Input: Connects to the provided DC power supply.
4. Fan Speed Switch: Three-position switch turns the fan speed
to low, high, or off.
Figure 2. Blower Standard Features
LED indicators are located on the front of the Blower (as shown
below). A lighted green LED indicates power is on, and a lighted red
LED indicates the presence of an alarm condition. For more
information on Alarms, see Chapter 3: Alarms.
Figure 3. LED Indicators

19-5802i-M-02 Rev 4 4
1.3 Blower Options
In addition to the standard features, several options are available
with the Model 5802i to fit the needs of your environment. Your unit
may include:
• Stainless steel chassis
• Collimator
• Locking mounting stand
• Wall stand
• Audible alarm
• Power cord lock
• Auto-Clean System
• Sensor input connectors
• Sensor input connectors with FMS output connector (FMS
output connector is only available with the sensor input
connector option)
The figures below show the back of the Blower with the sensor input
option only and with sensor input and FMS options.
Figure 4. Configuration with Sensor Only
Figure 5. Configuration with Sensor and FMS Options

19-5802i-M-02 Rev 4 5
1.4 External Sensor Option
The Model 5802i ionizer can operate with a Novx Series 7000,
3350 or 3360 to detect and automatically correct the offset balance.
The sensor antenna is placed at the target and feedback is sent to
the Model 5802i’s internal control system.
Figure 6. Sensor Options
Novx Process Monitor
Series 7000
Novx Passive/Active
Detection System
Series 3350/3360
Inhaltsverzeichnis
Andere ITW Gebläse Handbücher

ITW
ITW ION SYSTEMS 6432e Bedienungsanleitung

ITW
ITW SIMCO ION AEROSTAT XC Bedienungsanleitung

ITW
ITW Simco Ion IQ Power Fantom HL Bedienungsanleitung

ITW
ITW Simco-Ion Aerostat XC Bedienungsanleitung

ITW
ITW SIMCO ION Aerostat PC2 Bedienungsanleitung

ITW
ITW SIMCO ION Aerostat Guardian Bedienungsanleitung

ITW
ITW SIMCO-ION Phoenix Bedienungsanleitung

ITW
ITW Ion Systems 6422e Bedienungsanleitung