Make a Footprint Template -
GI 635 DV IPI
Materials:
Foam Core or Cardboard Straight Edge
Utility Knife Tape Measure Marker
1. Trim the board to a rectangle measuring
33 3/4” x 16 1/2”. (857mm x 419mm)
2. Draw a centerline at 16 7/8” (429mm).
3. Mark the rear corners at 11 3/4” (298mm) to
the left and right of center.
4. Measure and mark 3” (76mm) back from the
front corners on each side. Draw a cut-line from
those marks to the rear corner marks and trim
the sides along those cut-lines.
5. Tape this instruction sheet to the template for
future reference.
Hearth Requirements
Hearth protection in front of the GI 635 DV IPI must be
composed of masonry material extending at least 4 1/8”
(105mm) to each side of the fireplace opening and 12”
(305mm) forward from the fireplace facing material.
Raised Hearth: Forward hearth protection may be reduced
by two inches (51mm) for every inch of fireplace floor
elevation. See manual for further details.
A: Hearth Protection Width:
• Unit flush or raised: Min. 4 1/8” (105mm)
from fireplace opening
B: Hearth Protection Depth:
• Unit flush with hearth: 12” (305mm)
• Unit raised minimum 6” o floor: 0”
C: Side Trim Clearance:
• Up to 6” (152mm) depth, from fireplace center line:
21” (533mm)
D:Side Room Wall Clearance:
• From the fireplace center line: 24” (610mm)
E: Top Trim Clearance from hearth: 37” (940mm)
F: Mantel Clearance from hearth: See fig. 4.
Clearance Requirements
The following clearances and hearth specifications are
the minimum requirements for installing this appliance
into a solid fuel-burning fireplace.
A combustible surface is anything that can burn
(i.e. sheet rock, wallpaper, wood, fabrics, etc.). These
surfaces are not limited to those that are visible and also
include materials that are behind non-combustibles.
If you are not sure of the combustible nature
of a material, consult your local fire ocials. “Fire
Resistant” materials are considered combustible; they
are dicult to ignite, but will burn. “Fire-rated” sheet
rock is also considered combustible.
Always maintain the proper clearances to allow for
the flow of ventilation air around the insert.
Mantel and Top Trim Clearances
Measure clearances from the finished floor of the fireplace
opening.
Floor to Mantel Mantel Projection
A: 41” (104 cm) 12” (30.5 cm)
B: 40” (102 cm) 10” (25.4 cm)
C: 39” (99 cm) 8” (20.3 cm)
D: 38” (97 cm) 6” (15.2 cm)
E: 37” (94 cm) 4” (10.2 cm)
Minimum Ceiling Height from fireplace floor:
55 1/4” (140.3 cm)
Fig. 3.
Fig. 4.
© 2016 Jøtul North America, Inc. Gorham, Maine U.S.A.
GI 635 DV IPI Hearth Guide & Template