Jetting JetLogger V0 Einrichtungshandbuch

DARE TO DO IT DIFFERENTLY.
JetLogger
Product model/type: V0-V1-V2-V3 V.21.04
JETLOGGER SAFETY, INSTALLATION AND OPERATIONS MANUAL

Copyright © 2020 by Jetting AB
All rights reserved. No part of this publication may be
reproduced, distributed, or transmitted in any form or by
any means, including photocopying, recording, or other
electronic or mechanical methods, without the prior written
permission of the publisher. For permission requests,
write to the publisher, addressed “Attention: Permissions
Coordinator” at the address below.
Jetting AB, Murgatan 1, 522 30 Tidaholm, Sweden
jetting.se
info@jetting.se

Important safety notice
Read and understand all procedures and safety instructions before using the JetLogger with the
V0-V1 and V3 cable blower. Observe all safety information on this page and note specific safety
requirements as explained by procedures in both this manual and the manual of the cable blowing
machine. Failure to follow these instructions could result in serious personal injury or death.
Manufacturer
Jetting AB
Murgatan 1
522 30 Tidaholm
Sweden
jetting.se
info@jetting.se
+46 502 65 90 10
In this manual we will guide you thru the most common use
The use of the JetLogger for operations other than those described in this manual, are considered
dangerous and are discouraged. Use of this machine for work other than what is intended, relieves the
manufacturer from any responsibility, civil or penal. The manufacturer's responsibility ceases and the
warranty is voided when one of the following occurs:
A. When JetLogger is used for purposes other than what is detailed in this manual.
B. Tampering and/or modifications carried out without written approval of the manufacturer.
C. Not using original manufactured replacement parts.
D. Poor maintenance.
E. Not using safety devices or equipment.
F. Connection of this unit to machines and/or parts not produced or authorized in writing by the
manufacturer.
DARE TO DO IT DIFFERENTLY.
Caution: Noise will exceed 70 db

Table of contents
Description of the product 1 5
How to use the JetLogger with V0 2 6
How to use the JetLogger with V1/V2/V3 3 7
How to start the JetLogger App 4 8
Set up tablet for crash test protocol 5 9
Set up tablet for new session 6 10
Do a new session with last used data 7 12
Open old session 8 13
Add a new pipe to tablet 9 14
Add a new cable to tablet 10 14
Delete session, save and go back or save and send 11 15
Technical information 12 15
Documentation and disposal 13 17
EC Declaration of conformity 14 18
Notes 15 19
Section Page
DARE TO DO IT DIFFERENTLY.

1. Description of the product
The JetLogger is a professional documentation system for the installer/network owner who need an
ecient and professional electronic, documentation of the cable blowing process.
JetLogger is developed together with installers and network owners and can be used with Jetting’s
cable blowing machines models V0, V1, V2 and V3 prepared for JetLogger.
The JetLogger is based on a special developed software, and an industrial Galaxy tablet from Samsung
connected with a cable to the blowing machine to secure optimal work conditions in the field.
Based on individual input describing the job, cable and pipe + automatically input of temperature,
humidity and the exact position by GPS the JetLogger is monitoring for every 1.0 m the air pressure,
speed, distance and pushing force. This parameter is presented live on the tablet giving the user a full
view over the process.
Example:
After the process a PDF report with all data can be saved and distributed by mail. A library makes it
possible to create your own list of most used pipes and cables. In the software of the JetLogger you'll
find the Optimal Cable Pipe Combination system (OCPC system). The OCPC system is an intelligent
system helping you to get the optimal pipe and cable combination for optimal blowing conditions.
If wanted an automatically stop of the process, 'safety shutdown' can be made. This system will stop the
process if the preset value for pushing force are exceeded.
Via the GPS position a link to Google maps makes it possible to see the exact location.
DARE TO DO IT DIFFERENTLY.

2. How to use JetLogger with V0
• The JetLogger system for the V0 is integrated in the transport box of the machine.
• Check that the V0 is connected to the tablet and the machine by the USB cable.
• Connect battery or power supply to the V0.
• Connect compressor to V0 (make sure the air valve is closed).
• Insert the pipe and cable used for the job.
• Start by switch on the V0 by pushing the power button.
• Turn on tablet.
• Locate the JetLogger App and press on it to start the log menu.
• How to start the JetLogger App, see section 4.
JetLogger Box for V0
DARE TO DO IT DIFFERENTLY.

3. How to use JetLogger with V1/V2/V3
• The JetLogger system for model V1, V2, V3 is a stand alone system (Log Box) connected with the
machine by the supplied cable.
• Connect the machine and the Log Box with the supplied cable.
• Place the battery (Hitachi connector) on the left side of the Log Box.
• Connect compressor to the fiber blowing machine (remember to close the air valve and set the
emergency valve and regulator in closed position).
• Insert the pipe and cable used for the job.
• Start by switch on the power button on the battery holder (left side of the Log Box).
• Turn on tablet.
• Locate the JetLogger App and press on it to start the Log menu.
• How to start the JetLogger App, see section 4.
JetLogger Box for V1/V2/V3
DARE TO DO IT DIFFERENTLY.

4. How to start the JetLogger App
When you open the Jet Logger App you'll se the main Log menu, in the top you can:
• Change the language by pushing the flag.
• See the software version.
• See time, and battery status of the tablet.
• See indicator for charging.
• See the Wi-Fi symbol.
• See the mobil signal to operator.
In the menu you have 6 options to choose between:
1. Crash test protocol
• Used to perform a crash test and find max pushing force.
2. New session
• Used when a new job must be documented.
3. New session with last used data
• Used when a job must be documented and the cable, pipe and conditions can be
reused (save time for the setup).
4. Old sessions
• This is the memory where all saved protocols are located in PDF format.
5. Add pipe
• Register the pipe specifications for the most used pipes.
6. Add cable
• Register the cable specifications for the most used cables.
DARE TO DO IT DIFFERENTLY.

5. Set up tablet for crash test protocol
• You should always start with doing a crash test for that special cable and pipe you will be using
for the job.
• Start with pushing on 'Crash test protocol' and this menu appears:
• Fill out the items in the protocol (the yellow boxes must be filled in).
• Type in pipe, cable specifications for that cable and pipe you will do crash test.
• When all information is filled out the 'Start session box' turns green. Press on it to start.
• If software is asking for connection to 'SparkFun Pro Micro', press 'OK'.
• You can now start your crash test and the system will document the job.
• After you performed a success full crash test, where you have found the maximum pushing
force for the cable, tab on 'End Session'.
• You can now choose to 'Delete session', 'Save and go back' or 'Save and send'. Go to
section 11 for more information on how to do this.
DARE TO DO IT DIFFERENTLY.

6. Set up tablet for new session
• Start with pressing on 'New Session' in the main menu. This menu should appear:
• Fill out the items in the protocol (the yellow boxes must be filled in).
• Chose pipe. You will see the list of pipes that are stored in the memory. If not already
stored you can use 'Add pipe' either from the main menu or from the 'New Session Menu'.
• Type in the Color/Description of the pipe.
• Type in the pipe temperature (use a separate temperature measuring equipment).
• Chose cable. You will see the list of cables that are stored in the memory. If not already
stored you can use 'Add cable' either from the main menu or from the 'New Session Menu'.
• Type if you use cable tip (yes or no).
• Type the cable temperature (use a separate temperature measuring equipment).
• Note the meter marking from the cable and fill this into the protocol 'Start'.
• Chose the machine model; V0, V1, V2 or V3.
• Type in the lubricant specifications.
DARE TO DO IT DIFFERENTLY.
Dieses Handbuch passt für folgende Modelle
3
Inhaltsverzeichnis
Andere Jetting Industrieanlagen Handbücher