Keofitt STEAM BOILER Bedienungsanleitung

DON’T GAMBLE WITH YOUR SAMPLE™
STEAM BOILER
User ManUal

DOCUMENT VERSION LOG
The table below lists previous versions of this User Manual and states the major changes between
versions.
This version list is introduced in December 2016.
Version # Version date Major changes from previous versions
1 1th December 2016 Complete revision and new layout.

INTRODUCTION:
MANUFACTURER: KeottA/S
Kullinggade 31
5700Svendborg,Denmark
TYPE: SteamBoiler
YEAR OF INTRODUCTION: 2016
YEAR OF REVISED DESIGN: 2016
LAST UPDATED: 2016
TheEnglishversionofthisManualisthegoverningversionanditistheonlyauthorizedversion.Consequently,KEOFITT
cannot be held liable for other versions including translations of this Manual.

CONTENTS
1. PORTABLE STEAM CLEANING UNIT FOR CLEANING SAMPLE VALVES....................................... 5
2. PORTABLE MICRO BURNER .........................................................................................................6
3. HOW TO USE .................................................................................................................................7

KEOFITT USER MANUAL PAGE 5
1. PORTABLE STEAM CLEANING UNIT FOR CLEANING SAMPLE VALVES
TheKEOFITTSteamBoilerisasimpleandrugged,portabledevicedesignedtoprovidesteamathand
insamplinglocationswhereaxedsteamsupplyisnotavailable.
TheSteamBoilerisusedforsteamingsamplingvalvesasameansofcleaninganddisinfectingthe
samplingvalvepriortoextractingthesample.Thisensuresthesampletakenisfreeofanycriticallevel
ofmicroorganisms(seeIMPORTANTbelow)andisrepresentativeofthegreatercontentsoftheproduct
being sampled.
IMPORTANT
•Microorganismshavedifferentlethalitydependingontemperatureandexposuretime
•ThesteamproducedintheSteamBoilerisnotpressurized,sothesteamtemperatureis
onlyaround100°C(212°F)
•Makesurethatthetypeandlevelofcriticalmicroorganismsinyourapplicationaresuchthat
steamat100°C(212°F)willsufce.Partofthecleaninganddisinfectionisobtainedthroughthe
ushingeffectoftheowofsteam,whichremovesthemicroorganismbutnotnecessarilykillsit.
Theunitisgasredandholds400mlofwater.
WaterCapacity: approx.400ml
Dimensions: approx.150mmDia.x200mmH
Weight: approx.2.5kg
Materialsofconstruction: allwettedpartsofstainlesssteel,PTFEandaluminum

KEOFITT USER MANUAL PAGE 6
2. PORTABLE MICRO BURNER
The lab burner is designed with safety in mind.Thestable,
tip-resistantburnerprovidessafe,stableoperation.Thelever-
action igniter and ame adjustment knob ensure you get
thecontrollableamesizeyouneedwithinseconds.Itrells
quicklyandeasilyusingthellvalvebuiltintotheburnerbase
andastandardmulti-llbutanefuelcartridge.
This portable butane micro lab burner holds 30 grams of
butanewhenfullyrefueled,whichburnsfor35-60minutes,
depending on ame intensity. The output of this laboratory
burnerreaches2500BTUhouranditboilsa250mlbeakerof
waterinaboutveminutes.Itgeneratesaametemperature
ofupto2200For1200C.
•Fuel:butane
•Fuelcapacity:30grams/50ml
•Maximumburnrate:upto0.9grams/minute
•Burntime:about35minutesatmaximumburn,60minutesathalf-burn
•Maximumheatoutput:about2500Btu/hour(0.75kW)
•Maximumtemperature:about1200°C/2200°F
•Ignition:Push-buttonPiezo
•Unitsize:125mm(L)x80mm(W)x75mm(H);;4.9”(L)x3.1”(W)x3”(H)
•Unitweight(empty):400grams
•CEcertied

KEOFITT USER MANUAL PAGE 7
3. HOW TO USE
FILL FUEL
Placetheuniteitheronitssideorupsidedown,makingnotetoseeifanywaterisinside,asthiswill
drainoutiftheoutletissubmerged.Useasuitablebutanecartridgetoll,followingtheinstructionsfor
lling.Afterllingitisbesttowaitforanyexcessfumestodissipatethatcanoccurduringlling.
FILL THE VESSEL WITH WATER
Opentheplugontop,andllwithapproximately100to400mlwater,andreplacetheplug.
LIGHT THE BURNER
Turnthegascontrolknobon,andlistenforthegas,presstheopposingignitionswitchtolightthe
burner,adjusttheameheightandintensitytoboil.Bringthewatertoaboil,takingcaretokeepthe
endofthehoseawayfromanythingthesteam/condensatecouldharm.Aftersteamhasbeenstarted,
youcanturntheunitoffwiththeburnergascontrolknobandtaketoyoursamplepoint.
STEAMING THE VALVE
Hookthehandleoverthevalveandconnectthehosetothetopportofthevalve.ConsulttheKEOFITT
SamplingValveManualforfullinstructionsonsteamingandsampling.Starttheburnerandbringthe
waterbackuptosteam,whichshouldonlytakeafewmomentsdependingonthetimesincethetank
washeated.Steamthevalveoneminuteanddisconnecthosewithquick-coupling.
SAMPLING
Placeasanitizedrubberorstainlessplugoverthetopportandthecollectionvessel/bagtothebottom
portandoperatethevalveaccordingtothemanualtotakethesample.Aftersampling,thevalveshould
beushed,lledwithadisinfectantandcappedtokeepthevalveinacleanandsealedcondition
protectedfromtheenvironmentuntilthenextsampleprocedure.
CAUTION
ASAGASHEATINGDEVICEITISIMPERATIVETOOPERATEINASUFFICIENTLYVENTILATEDAREA,USING
GLOVES,PROTECTIVEGLASSESANDPROPERATTIRE.TAKINGALLNECESSARYPRECAUTIONS.
Seeillustrationsonnextpage.

KEOFITT USER MANUAL PAGE 8
CAUTION
• ASAGASHEATINGDEVICEITISIMPERATIVETOOPERATEINASUFFICIENTLYVENTILATED
AREA,USINGGLOVES,PROTECTIVEGLASSESANDPROPERATTIRE.TAKINGALLNECESSARY
PRECAUTIONS.
1. FILLBUTANEINTOBURNERPORT.
2. REMOVETOPFILLPLUG.FILLWATERINTOSTEAMERFILL
PORT–100TO400mL.
REPLACEPLUG.
3. TURNGASCONTROLON,USETOTURNBURNERONAND
OFFANDCONTROLFLAMEHEIGHTANDINTENSITY
4. PRESSIGNITERLEVERTOLIGHTBURNERPRELIMINARY

KEOFITTA/S
Kullinggade 31
DK-5700Svendborg
Denmark
Phone+4563167080
Fax+4563167081
info@keott.dk
www.keott.dk
Keottreservestherighttochangetechnicaldatawithoutnotice!
ForcompletesetofupdateddatasheetsandmanualsforKeottproductspleaserefertoourwebpagewww.keott.dk
Andere Keofitt Kessel Handbücher
Beliebte Kessel Handbücher anderer Marken

Vaillant
Vaillant uniSTOR VIH SW GB 500 BES Bedienungsanleitung

Radijator
Radijator BIO max 23.1 Bedienungsanleitung

Brunner
Brunner BSV 20 Bedienungsanleitung

Buderus
Buderus Logamax GB062-24 KDE H V2 Bedienungsanleitung

Potterton
Potterton 50e Datenblatt

UTICA BOILERS
UTICA BOILERS TriFire Bedienungsanleitung