Knowledge SEM-DSC Power Series Bedienungsanleitung

SEM-DSC PowerSeries Dual-Path (SEM300) - nstallation Guide
Alarm.com Dual-Path System Enhancement Module (SEM) is the most cost-effective and comprehensive solution to
migrate compatible DSC PowerSeries™ PC1616, PC1832, and PC 1864 panels to Alarm.com’s award-winning
interactive services. The Dual-Path SEM supports the 4G LTE cellular network and optional Broadband Ethernet. This
ensures the longest life cycle with the most secure and reliable service.
Equipment
System Enhancement Module
nstallation guide
https://answers.alarm.com/Partner/ nstallation_and_Troubleshooting/Panels/SEM/SEM-DSC_PowerSeries/SEM-DSC_Power…
Updated: Wed, 13 Sep 2023 15:24:21 GMT
1

Panel compatibility
The SEM-DSC PowerSeries is only compatible with the following panels that are version 4.20+:
• PC1616
• PC1832
• PC1864
Recommended tools and supplies
Note: These are not included.
• Screwdrivers: Small blade and Phillips
• Drill and bits for screws and/or wall anchors
• Ethernet cable
• Alpha keypad (Version 1.2+)
◦ Alarm.com strongly recommends installing an alpha keypad to ensure the failure to communicate (FTC) trouble
condition is displayed.
• Four-conductor, 22 AWG or larger stranded wire
The following table shows the maximum wire length for each gauge.
Gauge Maximum wire length
22 gauge 40 feet (12.2 m)
18 gauge 90 feet (27.4 m)
Prepare the system
Before powering down the system:
Verify panel compatibility
Verify that the panel is compatible by checking the version and year printed on the PROM chip inside the panel
enclosure.
https://answers.alarm.com/Partner/ nstallation_and_Troubleshooting/Panels/SEM/SEM-DSC_PowerSeries/SEM-DSC_Power…
Updated: Wed, 13 Sep 2023 15:24:21 GMT
3

Inspect for peripheral devices
1. Take inventory of all peripheral devices (wireless receivers, zone expanders, keypads, power supplies, etc.) wired
to the system.
2. nspect peripheral device wiring to verify there are no loose ends or intermittent connections between the device
and system.
Note: The presence of peripheral device issues can often cause the SEM installation process to take longer than
expected.
3. Verify all peripheral devices are supervised by the panel. To verify peripheral devices are supervised by the panel:
a. Press [*][8].
b. Enter the installer code.
c. Press [903].
4. Reset supervision if necessary. To reset supervision:
a. Press [*][8].
b. Enter the installer code.
c. Press [902].
https://answers.alarm.com/Partner/ nstallation_and_Troubleshooting/Panels/SEM/SEM-DSC_PowerSeries/SEM-DSC_Power…
Updated: Wed, 13 Sep 2023 15:24:21 GMT
4

Disarm and power down the panel
1. Verify the panel is disarmed and clear of any alarms, troubles, or system faults.
2. f you do not know the current installer code, check the installer code at the panel before powering down the panel.
3. Then remove AC power and disconnect the backup battery to completely power down the system.
https://answers.alarm.com/Partner/ nstallation_and_Troubleshooting/Panels/SEM/SEM-DSC_PowerSeries/SEM-DSC_Power…
Updated: Wed, 13 Sep 2023 15:24:21 GMT
5

Create an Alarm.com account
1. Create a new Alarm.com customer account using the Partner Portal or MobileTech app. The ME located on the
Alarm.com module will be needed to create this account.
2. During the account creation process, you are prompted to enter the current installer code on the panel. Alarm.com
uses this code to access panel programming and read information stored on the panel.
https://answers.alarm.com/Partner/ nstallation_and_Troubleshooting/Panels/SEM/SEM-DSC_PowerSeries/SEM-DSC_Power…
Updated: Wed, 13 Sep 2023 15:24:21 GMT
7

3. At the end of the Create New Customer process, you are able to print or email a Welcome Letter for the customer,
which includes login information for the Alarm.com Customer Website.
For more information about creating a customer account, see How to create an Alarm.com customer account.
After powering down the system:
Remove third party communication
f there are any third-party communicators installed or a POTS line connected to the panel, remove them.
The SEM is not compatible with POTS, P/GSM devices, or other third-party communicators. Therefore, the SEM should
be the only communication device installed for alarm signaling to the monitoring station.
Connect the SEM
Mounting
Before mounting the SEM to the wall:
1. Evaluate how the wiring cables will be routed from the SEM to the panel.
2. Remove the snap-off plastics. There are two routing options available: the side of the enclosure for side routing or
the rear of the enclosure for wall routing.
3. Verify the wiring of the primary antenna, diversity antenna, and ethernet dongle are routed correctly.
Note: The Cat-M variant (indicated by the ME910 Telit radio) only requires the primary antenna.
https://answers.alarm.com/Partner/ nstallation_and_Troubleshooting/Panels/SEM/SEM-DSC_PowerSeries/SEM-DSC_Power…
Updated: Wed, 13 Sep 2023 15:24:21 GMT
8

When ready to mount:
1. Press in on the thumb tabs located at the bottom of the enclosure, then swing up the top half of the enclosure
cover to expose the internal components.
2. Place the SEM enclosure backplate against the wall at the desired mounting location and mark the four mounting
holes.
3. Using the provided mounting screws and wall anchors (if needed), place the first mounting screw through the top-
right enclosure hole. This screw will be used to hang the SEM from the wall while mounting and should not be
tightened until the last step.
4. Place the second mounting screw through the bottom-left mounting hole. This screw is used to level the enclosure
on the wall and should not be tightened until the last step. A standard leveling device may be used to ensure the
unit is level.
5. Place the third mounting screw through the top-left enclosure hole. This screw should be tightened fully against the
unit and wall before moving to the next step.
6. Place the final mounting screw through the bottom-right enclosure hole. This screw should be tightened fully
https://answers.alarm.com/Partner/ nstallation_and_Troubleshooting/Panels/SEM/SEM-DSC_PowerSeries/SEM-DSC_Power…
Updated: Wed, 13 Sep 2023 15:24:21 GMT
9

against the unit and wall before moving to the next step.
Important: This screw is critical for the wall tamper functionality and should not be overlooked.
7. Tighten the first two mounting screws fully to the unit and wall to complete the mounting process.
https://answers.alarm.com/Partner/ nstallation_and_Troubleshooting/Panels/SEM/SEM-DSC_PowerSeries/SEM-DSC_Power…
Updated: Wed, 13 Sep 2023 15:24:21 GMT
10
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Beliebte Sicherheitssystem Handbücher anderer Marken

EDM
EDM Solution 6+6 Wireless-AE Bedienungsanleitung

Highway Safety Group
Highway Safety Group EA401 Bedienungsanleitung

Siren
Siren LED GSM Bedienungsanleitung

Detection Systems
Detection Systems 7090i Montageanleitung

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Bedienungsanleitung

Siemens
Siemens FDM273 Bedienungsanleitung