Kolin KAG-110RSINV Bedienungsanleitung

www.kolinphil.com.ph
www.kolinphil.com.ph
USER MANUAL
WINDOW TYPE INVERTER
AIR CONDITIONER
Thank you for choosing our product.
For proper operation, please read and keep this manual carefully.
If you have lost this manual, please contact the local agent or visit our site for assistance.

MODELS:
KAG-110RSINV
KAG-145RSINV
KAG-200RSINV
KAG-240RSINV

CONTENTS
Thank you for choosing the air conditoner.Our design is based on the best eff-
iciency and the lowest noise operation and it can keep the room comfortable.
Please read this operating manual carefully before operating the unit and keep it
for consultation.
Structure mechanism and Installation
The Refrigerant 1
Function 3
Precautions 2
Power requirement 4
Installation 5
Notes for installation 8
Operation procedure 9
Air direction adjustment 9
10
Remote control panel
Remote control operation procedure 15
Operation Tips 16
Care and maintenance
Caution 17
Care and maintenance 19
Troubleshooting guide 20
After service 21
22
This appliance is not intended for use by persons (including children) with reduced physical,
sensory
or mental capabilities or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

The Refrigerant
•To realize the function of the air conditioner unit, a special refrigerant circulates in
the system. The used refrigerant is the fluoride R32, which is specially cleaned.
The refrigerant is flammable and inodorous. Furthermore, it can leads to
explosion under certain conditions. But the flammability of the refrigerant is very
low. It can be ignited only by fire.
•Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm
to the ozonosphere. The influence upon the greenhouse effect is also lower. R32
has got very good thermodynamic features which lead to a really high energy
efficiency. The units therefore need a less filling.
WARNINGS (for using R290/R32 refrigerant only):
•Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
•The appliance shall be stored in a room without continuously operating ignition
sources (for example: open flames, an operating gas appliance or an operating
electric heater).
•Do not pierce or burn.
•Be aware that the refrigerants may not contain an odour.
•Appliance should be installed, operated and stored in a room with a floor area
2
larger than 4 m .
•Compliance with national gas regulations shall be observed.
•Keep ventilation openings clear of obstruction.
•The appliance shall be stored so as to prevent mechanical damage from
occurring.
•A warning that the appliance shall be stored in a well-ventilated area where the
room size corresponds to the room area as specified for operation.
•Any person who is involved with working on or breaking into a refrigerant circuit
should hold a current valid certificate from an industry-accredited assessment
authority, which authorises their competence to handle refrigerants safely in
accordance with an industry recognised assessment specification.
•Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of other skilled
personnel shall be carried out under the supervision of the person competent in
the use of flammable refrigerants.
Explanation of symbols displayed on the unit ( For the unit adopts R32/R290 Refrigerant only):
WARNING
CAUTION
This symbol shows that this appliance used a flammable refrigerant.
This symbol shows that the operation manual should be read carefully.
This symbol shows that a service personnel should be handling this equipment with reference to
installation manual.
This symbol shows that information is available such as the operating manual or installation manual.
!
- 1 -
CAUTION
CAUTION

Precautions
Caution: Risk of fire/
flammable materials
(Required for R32/R290 units only)
IMPORTANT NOTE: Read this manual
carefully before installing or operating
your new air conditioning unit. Make sure
to save this manual for future reference.
The air conditioner should be installed in accordance with national wiring regulation.
Air Conditioner should be properly grounded. Incorrect grounding may cause electric
shock.
•Do not connect air conditioner to multi-purpose socket. Otherwise, it may cause fire
hazard.
•Do install the air switch. If not, it may cause malfunction.
•Do not spill water on the remote controller, otherwise the remote controller may be
broken.
•Do not spray water on air conditioner. It may cause electric shock or malfunction.
•Do not extend finger or objects into air inlet or air outlet. It may cause personal
injury or damage.
•Do not step on air conditioner, or put heavy objects. It may cause damage or
personal injury.
•Do not block air outlet or air inlet. It may cause malfunction.
•Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause
electric shock.
•Do not repair air conditioner by yourself. It may cause electric shock or damage.
Please contact dealer when you need to repair air conditioner.
•Maintenance must be performed by qualified professionals. Otherwise, it may
cause injury or damage.
•The appliance is not to be used by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction.
•Children being supervised not to play with the appliance.
Please install the devices for short-circuit protection and electrical leakage protection
when installing the air conditioner. According to the local safety regulations, use
qualified power supply circuit and circuit break.
Working temperature range
Operating Temperature Range
Indoor side DB/WB(°C)
Outdoor side DB/WB(°C)
Maximum cooling
32/23
43/-
The operating temperature range (outdoor temperature) for cooling only unit is
18°C~43°C.
- 2 -

- 3 -
Function
Introduction
Window type room air conditioners can
regulate the room temperature and dry
the room. It is convenient for your work, study
and life. It can be widely used in residence,
so on.
Room
temp.
Spring Autumn
Winter
Wind
direction
Summer
Cooling in summer Dehumidifying in rainy or
humid season
In hot summer, Air conditioner can
cool down theroom air by transferring
heat out.
Without reducing the room temp., air
conditioner can dehumidify and make
the room air dry and comfortable.
Dry

- 4 -
Power requirement
Rated voltage :230V~ 60Hz
●The electric components will be damaged when
the voltage is too high. If the voltage is too low,
the compressor will vibrate violently to damage
the refrigerant system and easily cause the
compressor and electric components not work.
To ensure the reliable earthing, please do not connect earth
wire to the following places:
Earth wire
Water pipe
The ground must be connected.
● Special socket must be used. Furthermore, the
socket and wiring must conform to the wiring
regulations. And the earthing method must be
reliable.
protection switch of enough power capacity
and air switch with enough space.

- 5 -
Installation
Installation precaution:
Window type conditioner is so valuable and the
improper installation of it will cause a lot of da-
mage! Please associate the professional tech-
nician to install the unit and don’t install it by yourself. Otherwise, we are not
responsible for the damage like this.
Location:
●The condensation water must be drained away conveniently.
●Install air conditioner unit far away from TV set or radio etc. to avoid distur-
bing video or voice.
● In salt and coastal area or place where is near thermal springsand polluted
by sulphurous gas, or other special areas, please contact the seller before
use.
●Avoid other heat sources or direct sun light.
●Avoid a place where is easy for children to touch.
●
Don't use the unit in the immediate surrondings of a laundry,a bath,a shower
or a swimming pool.
● For window type air conditioner with remote control, install in a location
where is strong electromagnetic disturbance, you should contact the seller
in advance to avoid the malfunction in use.
How to install:
●
Choose a location where there are
no any obstacle surrounding the
unit, and the plug is accessible.
● Prepare the installation hole slig-
htly bigger than unit size.
● Choose the installation space ac-
cording to the following diagram.
Over
1500 mm
The distance of obstructions from
window unit inside should be upper
300mm, lower 1500mm, left 500mm,
right 500mm, front 1500mm.
500mm 500mm
300mm 300mm

- 6 -
Installation procedure:
1) Remove the sticker from the front panel.
3) Fill up sews in the cabinet with sponge
or foam.
2) Put the unit into the installation hole.
● The installation place should be strong
enough to avoid the enlargement of
noise or vibration.
Installation assistance:
● Use iron support
The installation hole should be stro-
ng enough to support the air condit-
ioner.
If it cannot, iron support has to
be used
outdoors. Iron support sho-
● Use sunshade board
Air conditioner should avoid anything
to be dropped into it and avoid direct
sunshine. If there is no cover on it,
you should contact the seller for inst-
alling the sunshade board. When in-
stalling the sunshade board, don’t let
it block the air inlet at the side grille.
Wall
Wooden
frame
Sunshade
board
Rubber
plate
Support
Horizontal line
● When installing the unit, it should slant
down to the back to make sure the
condensation water can be drained
away conveniently.(Slant about 3
(Shown at right figure.)
。 。
+
-1 ) 。 。
+
-13
。 。
+
-13
。 。
+
-13
Inclined about

- 7 -
Drain water :
Drain pan and drain hose need to be installed before using. Drain hose is
not included in the products, you need to purchase it locally to satisfy your
particular needs. Use the following procedure to install drain pan and drain
hose.
1. Slide out the chassis from the cabinet.
2. Install the drain pan to the corner of the cabinet with 2 screws.
3. Connect the drain hose to the outlet on the drain pan bottom.
4. Slide the chassis into its original place in the cabinet.
To get the maximum cooling efficiency , the air conditioner is designed to
splash the condensation water on the condenser coil . If the splashing sound
annoy you , you can remove the rubber plug from the chassis to lower the
noise, which also cause a bit loss of performance.
Dieses Handbuch passt für folgende Modelle
3
Inhaltsverzeichnis
Andere Kolin Klimaanlage Handbücher

Kolin
Kolin Primus Gold KSG-IWF-10WFY-8K1M32 Bedienungsanleitung

Kolin
Kolin KAM-55CMC32 Bedienungsanleitung

Kolin
Kolin KLM-SC40-4F1M Bedienungsanleitung

Kolin
Kolin KAM-55CMC32 Bedienungsanleitung

Kolin
Kolin KLM-IF70-3D3M Bedienungsanleitung

Kolin
Kolin KLG-SF70-4D3M Bedienungsanleitung

Kolin
Kolin KLG-IF40-3D1M Bedienungsanleitung

Kolin
Kolin KLM-SS40-4F1M Bedienungsanleitung

Kolin
Kolin E Series Bedienungsanleitung

Kolin
Kolin KLG-IF70-2C1M Bedienungsanleitung