Function Introduction
Alarm Host Diagram
Functions Settings
Initialization
Enter Settings
Exit Settings
Factory Reset
Coding of Remote Controller
Delete Remote Controller
Coding of Defense Zone
Delete Defense Zone
Change Password
Change Operation Password
Change Program Password
Clock Setting
Timing Settings
Timely Arm
Timely Disarm
Timing Control
Out Arm Delay Setting
Alarm Delay Setting
Alarm Number Setting
Delete Phone Number

11-12
12-12
12-12
12-13
13-13
14-14
14-14
15-15
15-15
15-15
16-16
15-15
16-17
17-17
17-18
18-18
18-18
18-19
20-20
21-21
22-22
22-22
19-19
CONTENTS
SMS Number Setting
Delete SMS Number
SMS Notification for Arm/Disarm
Defense Zone Programming
Home Arm Defense Zone Setting
Voice Recording
Siren Setting
Operation Instructions
System Status
Remote Controller Operate
Out Arm
Home Arm
Disarm
Answer Alarm Call
Remote Control
Emergency Help
System Dialing Function
Alarming Record Checking
Notes
Technical Parameters
Components List
Care and Maintenance
GSM Signal Checking

ΚΜ
ΚΜ
1
7 wired and 99 wireless defense zones;
LCD screen with time clock display;
Voice prompt for all operations;
3 groups of timely arm and disarm;
Can store 6 phone numbers: when alarming, system will make alarm call
to these numbers automatically;
Can store 3 SMS numbers: when alarming, system will send alarming SMS
automatically;
10-second automatic message recording;
Built-in artificial intelligent digital voice announcer;
Built-in artificial intelligent English message;
Users can make calls by using keypad on alarm panel, just like a telephone;
One-key-control function: Out Arm, Home Arm, Remote Arm;
Arm/ disarm by SMS or call remotely;
SOS, fire, gas, door, hall, window, balcony, and boundary places alarm;
Real-time, delay, 24 hours, bypass defense zones programming function;
Wireless coding: easy to add additional wireless accessories;
Remote control Arm, Disarm, Monitor, and Intercom by phone;
SMS alert for power failure or recovery;
Built-in AAA NI-HI rechargeable battery: make alarm when power off.
In order to make the main unit get the wireless signal well for all wireless
accessories, please put the alarm host at the central place of your defense
area.
Make sure it’ away from large metal objects and house hold appliances
which may cause high frequency interference, as well as barriers such as
reinforced concrete wall or fire door, etc.
Function Instruction
Alarm Host Diagram
s
Function Introduction
Alarm Host Diagram

2
Wired terminal block:
Alarm Panel front schematic diagram:
Alarm Panel back schematic diagram:
Speaker PIR Siren
Alarm Host Diagram
Alarm Host Diagram

LB-
LB+
GND
Z1
GND
Zone 2
Zone 3
GND
Zone 4
Zone 5
GND
Zone 6
Zone 7
1. “LB -” and “LB +”are to connect external speaker. If you think
the internal speaker is not loud enough, pleasecontact us for
professional speakers.
2. Connect one cable of the wired sensor to GND and the other to
“Z1/Z2/Z3…/Z7”.
Ground
Wired sensor 2: support both NO and NC
Wired sensor 3: support both NO and NC
GND
GND
Wired sensor 4: support both NO and NC
Wired sensor 5: support both NO and NC
Positive of siren (red cable)
Negative of siren (black cable)
Wired sensor 7: support both NO and NC
Wired sensor 6: support both NO and NC
Positive of two-way speaker (red cable)
Negative of two-way speaker (black cable)
Ground
Wired sensor 1: support both NO and NC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15 SP+
SP-
3. Please pay attention to the siren connection. Do not mix the two
cables together when connecting. Otherwise, it will damage the
transistor in the main panel.
Note:
3Alarm Host Diagram
Alarm Host Diagram

LCD display:
1. Initialization
Please insert SIM card and plug in power adaptor, and then power on the
system, all the LED lights will be on for 2 seconds and you will hear a long
beep; the system comes into initialization. After the time clock displays on
the LCD screen, the [GSM] starts flashing and the main unit starts to detect
the GSM network until a long beep.
Then the [GSM] indicator goes out indicating the system comes into disarm
status.
Finally, turn on the backup battery switch.
In the state of disarm, input 4-digit password by the keypad on the main
unit and press [ # ] button to confirm. You will hear a voice prompt: please
enter instruction. At the same time, [ SET ] indicator is on without flashing
and [0000] displays on the screen, indicating the system enters setting status.
You can perform different settings repeatedly as long as the system keeps in
setting status. The system will exit setting mode and return to disarm status
if you don’t press any keypad button for 40 seconds.
2. Enter Settings
ΚΜ
Functions Settings
4
Alarm Host Diagram
Functions Settings

Note: In setting status, press
Operating method: [ XXXX ] [#]
Ö
Ö
Xindicates the new 4-digit password.
LCD display:
Press [ ] and [#] buttons, the main unit emits a long beep and exits settings.
The [ SET ] indicator goes out and the system returns to disarm state.
5VKXGZOTMSKZNUJ 澬澭澬#澭
*
*
In disarm status, use keypad to input [95175308246] and press [#] to confirm,
all the LED indicators will be on for 2 seconds and you will hear a long beep.
The main unit gets all its settings cleared and restores to its factory settings
successfully.
Operating method: [95175308246] + [#]
The remote controller has to be code to the alarm host in order to perform
normally.
In setup state, use keypad to input [20], input the remote controller number
[1~8], and then press [ # ] to confirm. The main unit emits a long beep and
you will hear “ remote control coding ”. The [ ] indicator is on without
flashing; press any button on the wireless remote controller, the main unit
makes a long beep and you will hear “coding completed”, [ ] indicator
goes out, indicating the remote controller succeeds in coding.
ÖÖ
Operating method: [20] [A] [#]
A indicates: 1~8 remote controllers number.
5. Coding of Remote Controller
3. Exit Settings
4. Factory Reset
5
Functions Settings
Functions Settings
can delete the numbers input.
The system default password is [8888].

ÖÖ
ÖÖ
You can add maximum 8 remote controllers.
LCD display:
A indicates: 1~8 remote controllers number.
XX indicates: 01 ~99 defense zones number
LCD display:
6Functions Settings
Functions Settings
In setup state, use keypad to input [21 ], then input the remote controller
number [1-8], and then press [ # ] to confirm. The main unit emits a long
beep and the [Signal] indicator flickers once. You will hear a voice prompt
“delete completed”.
Operating method: [21] [A] [#]
In setup state, use keypad to input [23], input the defense zone number
you want to code [ 01~99 ], and then input [#] to confirm. The main unit
emits a long beep and the corresponding defense zone is displayed on
the screen. You will hear a voice prompt “detector coding”.
Then trigger a wireless detector to emit a wireless signal; after receiving
the signal, the main unit makes a long beep, and you will hear “coding
completed”, the [ ] indicator goes out at the same time.
7. Coding of Defense Zone
Operating method: [23] [XX] [#]
6. Delete Remote Controller
‘t ‘s
The remote controller can control the main unit after it deleted.
Wireless detectors have to be coded to the main unit in order to trigger
it alarm.

ÖÖ
ÖÖ
ÖÖ
In setup state, use keypad to input [24], then input the defense zone
number you want to delete [ 01~99 ], and then input [#] to confirm.
The main unit emits a long beep and the defense zone indicator
flickers once.
You will hear a voice prompt “delete completed”.
Operating method: [24] [XX] [#]
XX indicates: 01 ~99 defense zones number
In setup status, use keypad to input [30], then input the 4-digit new
password, and then press [#] to confirm. The main unit will make a long
beep and you will hear a voice prompt “setting completed”.
Operating method: [30] [XXXX] [#]
XXXX indicates: the new 4-digit password
For example: change the system password to 1012
Operating method: [30] [1012] [#]
LCD display:
In setup status, use keypad to input [ 31 ], then input the 4-digit new
password, and then press [#] to confirm. The main unit will make a long
beep and you will hear a voice prompt “setting completed”.
8. Delete Defense Zone
9. Change Password
2). Change Program Password
The wireless detector can’ control the main unit after it’ deleted.
1). Change Operation Password
Operation password is the password used to disarm or remote control.
Program password is the password you should input in order to setup
the system.
t
s
7Functions Settings
Functions Settings
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Konlen Sicherheitssystem Handbücher
Beliebte Sicherheitssystem Handbücher anderer Marken

EDM
EDM Solution 6+6 Wireless-AE Bedienungsanleitung

Highway Safety Group
Highway Safety Group EA401 Bedienungsanleitung

Siren
Siren LED GSM Bedienungsanleitung

Detection Systems
Detection Systems 7090i Montageanleitung

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Bedienungsanleitung

Siemens
Siemens FDM273 Bedienungsanleitung