● After the installation, please make sure the cables are fixed well.
OU TPU T INP UT
L-0
N-I
N-0
L-I
.LOAD CHARACTERISTIC DIAGRAM
INSTALLATION .
1. Please check if the AVR is damaged in transit. If it is damaged or
less-component, please do not turn on the AVR and inform the dealer.
2. Notice for installing the AVR
Connecting with a power cable: please use the suitable socket with
the over current protection. Do not put all the load on the same socket
and notice the capacity of the socket. Please check the connecting
details as below.
●
Notice:★ Please keep the packing materials for moving in the future;
The series of product are too heavy, please handle with care★ 。
AC Input
Load
Delta 1 KVA,Delta 2 KVA
● Connecting with the terminal blocks: notice the capacity and its
specification of the cable. For 3000VA AVR, the cable should be
2
bigger than 4.0mm . For 5000VA AVR, the cable should be bigger
2
than 6.0mm . Please check the connecting details as below.
Delta 3 KVA,Delta 5 KVA
Load
AC Input
.CAUTION
1. Please handle with care and put the AVR upward.
2. Never put the AVR in the place with strong vibrations.
3. Do not put the metal like iron wire, iron nail etc. to the heat elimination hole
for avoiding short circuit. Do not put the goods near the heat elimination
hole for keeping aeration.
4. Never expose the AVR to the direct sunlight or the rain, never install it in
an excessively damp environment.
5. Away from the fire source, do not install the
AVR in the high temperature environment.
6. Never install the AVR in the Corrosive
Atmospheric Environment.
7. Never install the AVR near liquid.
8. Keep the AVR away from places where child can tough it.
9. The AVR will heat when it is working, it is a normal phenomenon. Do not
cover the AVR for avoiding the fire disaster.
10.When the AVR is working, if there is abnormal like the peculiar smell or fire is
found, please cut the power immediately and send it to the appointed place. No
maintaining the machine for avoiding break out the electric shock.
11. Do not open the AVR panel when power is connected.
.ABNORMAL
Abnormal Cause Solution
AVR can't turn on
the input breaker is
fail to work because
of the AVR is over load
reset the breaker
AVR gets wrong Please send the AVR
to the dealer for service
The buzzer alarm The AVR is over load Remove some loads
The display shows
the wrong indication
AVR gets wrong Please send the AVR
to the dealer for service
AVR gets wrong Please send the AVR
to the dealer for service
.HOW TO USE
1. Please plug the input power cable to the output socket which it can supply
the enough current.
2. Connecting load to the output socket which is on the rear panel of the AVR,
please make sure the load is not over the rated Capacity.
3. Push “ ON ”, the green LED continuous bright, the display shows“ ”
and the rest DELAY time. The AVR is turning on under delaying mode and
detecting AC power.
4. According to the load, choose the long delay or short delay. If the load
as the refrigerator, please choose the long delay, otherwise choose the short
delay. Long press the button“DELAY SEL” 3 seconds for switching
the long or short delay, the yellow LED bright shows the long delay, the LED
off shows the short delay.
5. DELAY is finished, the AVR supply the stable voltage for load.
6. When the voltage is over-high or over-low, the display shows the status with
the RED LED flashes. When the input voltage is over-high, the AVR cut the
output for protection. When the input voltage is over-low,AVR do not cut the
output, some facilities still can work but maybe in abnormal, users should
cut off some facilities which it is abnormal. When the AVR is over load, the
display shows “ ” and with the buzzer alarm, users should cut off part
of the load and make it smaller than the rated capacity, otherwise the AVR
stop the output.
7. AVR has the temperature protection function, when the temperature is over
the setting value, the AVR cut off the output and alarm with the buzzer. Users
should cut part of the load and restart the AVR after the temperater is
cooling.
8. Push “OFF”and cut off the AVR.
9. There will be a little noise when AVR is working.
User's manual
Output power(%)
Input voltage(V)
300
Wide Range AVR
Wide Range AVR Delta 1 KVA
Delta 2 KVA
Delta 1 KVA Delta 2 KVA
Delta 3 KVA Delta 5 KVA Delta 3 KVA Delta 5 KVA