1. Introduction 3
1.1 Features 3
1.2 Packaging 4
1.3 Front Panel 5
1.4 Side View 6
1.5 Installing the battery 7
2. Operation 8
2.1 Power on 8
2.2 Menu & functions 8
2.3 PTZ controller 10
2.4 Video setting 12
2.5 Colorbar generator 13
2.6 Cable tester 13
2.7 Data monitor 14
2.8 Device setting 14
2.9 Address search 15
3. Speciations 16
Safety instructions
This product should be installed in line with installation rules, preferably by a qualified electrician. Incorrect installation and use can lead to risk of electric shock or fire.
Before carrying out the installation, read the instructions and take account of the product’s specific mounting location.
Do not open up, dismantle, alter or modify the device except where specifically required to do so by the instructions.
All Bticino products must be opened and repaired exclusively by personnel trained and approved by Bticino.
Any unauthorised opening or repair completely cancels all liabilities and the rights to replacement and guarantees.
Use only Bticino brand accessories.
GB

3
1. Introduction
The CCTV tester is developed for the On-Site installation and maintenance of video monitoring system.
It can be used for displaying video, controlling PTZ, generating images, capturing data of RS485 and testing LAN
cable etc.
1.1 Features
2.8”TFT-LCD , 960 (H) × 240 (V) resolution.•
PTZ control: Pan/tilts the P/T unit zooms in/out the lens, adjusts the focus and aperture; sets and calls the•
preset position.
Video displaying: automatically adapts and displays the video format of NTSC/PAL.•
LCD Brightness/Contrast/Color Saturation are adjustable.
Video Level testing: video signals measured in IRE or mV.•
Video Generating: the tester PAL/NTSC generates colorbar video pattern.•
Data analyse: captures and analyzes RS485 controlling data.•
Cable testing: tests LAN cable measures the connecting status.•
Multi-interface and Multi-baudrate: supports RS232 and RS485 baud rate ranging from 150, 600 to•
19200bps.
Multi-protocol: supports more than twenty PTZ protocols. For example, PELCO-P, PELCO-D, SAMSUNG etc.•
PTZ address scanning: searches up the ID of PTZ camera.•
Lithium Ion Polymer Battery (3.7V DC2000mAh).•
It can last 11 hours for normal use after charging for 4 hours.

4
1.2 Packaging
Item description Item picture Qty
CCTV tester 1
LAN Cable Tester 1
Lithium Ion Polymer Battery
1
Power supply (5V 2A)
1
BNC Cable
1
Safety cord 1
RS485 data cable 1
RS232 cable 1
User manual 1

5
1.3 Front Panel
1
The power indicator: it lights green while the tester is powered on.
2
The data-reception indicator: it lights red while the data is being received.
3
The data-transmission indicator: it lights red while the data is being transmitted.
4
The charge indicator: it lights red while the battery is being charged.
As the charging is complete, the indicator turns off automatically.
5
The display Icon of battery electricity: it displays the electric quantity.
6
Main-menu: it shows main functions of CCTV tester.
7
Sub-menu: shows and sets the values of functions.
8
Long-pressing it more than 2 seconds to turn on/off the tester; short-pressing to turn on/off the
PTZ controller menu displaying.
9
Menu key: it pops up the main-menu; constant-press it or press the
or
key can shift between
functions.
A
Setup key: press it or press left or right key to enter sub-menu to set the parameters of functions.
B
Upward: Select the item which will be set or add the value of the parameter. Tilt the PTZ upward.

6
C
Leftward: Enter the sub-menu or select the parameter whose value will be changed.
Reduce the value of the parameter. Pan the PTZ left.
D
Rightward: Enter the sub-menu or select the parameter whose value will be changed.
Add the value of the parameter. Pan the PTZ right.
E
Downward: Select the item which will be set or reduce the value of the parameter.
Tilt the PTZ downward.
F
Confirm/Open: Confirm the setting of parameters; open the iris.
G
Return/Close: Return or cancel while setting parameters of the menu; close the iris.
H
Near focus: Focus the image nearby.
I
Far focus: Focus the image faraway.
J
TELE: zoom in the image.
K
WIDE: zoom out the image.
1.4 Side view
MReset the default settings of parameters.
NExternal power supply (DC, 5V): It is highly recommended to use the equipped power adapter.
OUTP cable port: please use together with UTP LAN cable tester.
PRS232 interface: RS232 communication for the PTZ.
QVideo input (BNC input interface): Inputs the video.
RVideo output (BNC output interface): Outputs the video.
SRS485/422 Interface: RS485/RS422 communication for the PTZ.
THole for the safety cord.
INPUT
Left side
Right side

7
1.5 Installing the battery
The tester has built-in lithium ion polymer rechargeable battery.
The battery cable inside battery cabin should be disconnected for safety during transportation!
Prior to the use of the instrument, the battery cables inside the battery cabin should be well
connected and the color of cables should be at the same side.
Usually it need not to disconnect the cable at the normal use, pressing
key
continuously can power on or off the tester.
At the first time of use, the batteries should be completely exhausted and then recharged
for 4 or 5 hours.
The Charge Indicator
lights red when charging the battery, the charge indicator turns
off automatically when the charging is completed.
Notice: When the Charge Indicator•
turns off, the battery is approximately 90% charged.
The charging time can be extended for about 1 hour and the charging time within 8 hours
will not damage the battery.
The tester can work as usual while it is being charged, however. But the charging time will be extended.•
Press the RESET key at the right of the instrument to restore the default settings when the instrument
works abnormally.
Unlock the battery cover by pushing horizontally as the direction illustrated
Warning: Connect the terminal of the battery with the direction illustrated.
Please take care of the polarity of terminal.
(The wires of the same color should be both at the one side)
Lock the batteries by pressing as the direction illustrated

8
2. Operation
2.1 Power on
Continuously press
(at least 2 seconds) to power on/off the CCTV tester. When the CCTV tester is powered
on, press MODE key the main-menu will pop up.
2.2 Menu & functions
Press MODE key continuously or press the
or
key to select the function (PTZ controller, Video settings,
Colorbar generator, Cable tester, Data monitor, Device setting) and enter corresponding function setting sub-menu.
Press SET key to set the parameters in function sub-menu.
Note: When the CCTV tester is powered on, it will return to the function which is being operated before it is turned
off.
1. PTZ controller
Display the input video images. Pan/tilt the P/T unit and
zoom in/out the image. Setup the controlling parameters
like protocol, communication port, baud rate, PTZ ID,
pan/tilt speed; set and call preset position.

9
2. Video setting
Adjust the LCD brightness, Contrast, Color saturation.
Video Format displaying and Video level testing.
3. Colorbar generator
Output or receive seven different forms of video color
bar to tester monitor, cable or other equipment.
4. Cable tester
Test LAN cable or telephone cable.
The connecting condition and the sequence of wires
will be displayed, as well as the serial number of the
cable tester kit.
5. Data Monitor
Captures the protocol from the controlling system
and display command data. It is helpful to debug and
maintain RS485 communication.
Adress search o :
6. Device setting
Set the parameters of the CCTV tester.
(Auto poweroff/Keypad tone/Language/Brightness)

10
2.3 PTZ Controller
Display the input video images. Pan/tilt the P/T unit and zoom in/out the image.
Setup the controlling parameters like protocol, communication port, baud rate, PTZ ID, pan/tilt speed; set and call
preset position.
The following connections should be confirmed before use
a. The Video In interface of the CCTV tester and the output interface of camera
b. Data A+ of the CCTV tester and A+ of the PTZ camera or controlling device, data B- of the instrument
and B- of the PTZ camera or controlling device
Note: Don’t connect communications interface with a circuit voltage higher than 6V.
VIDEO OUT
DATA A+
DATA B-
VIDEO IN
IN OUT
VIDEO RS485
D-/B D+/A
a- Press SET key to enter the sub-menu of PTZ controller.
b- Press the
or
key to select the parameter
which we want to change the value.
c- Press ENTER key to save the change or press
RETURN key to give up the change.
d- Press SET key to exit the sub-menu.
e- Press POWER key to full-screen the image.
Inhaltsverzeichnis
Andere LEGRAND Prüfgeräte Handbücher
Beliebte Prüfgeräte Handbücher anderer Marken

SMART
SMART KANAAD SBT XTREME 3G Series Bedienungsanleitung

Agilent Technologies
Agilent Technologies BERT Serial Bedienungsanleitung

Agilent Technologies
Agilent Technologies N3280A Bedienungsanleitung

Vernier
Vernier Go Direct Voltage Bedienungsanleitung

Lifeloc
Lifeloc R.A.D.A.R. Bedienungsanleitung

Fluke
Fluke T5-600 Bedienungs- und Montageanleitung

PCB Piezotronics
PCB Piezotronics 8159-0112A Bedienungsanleitung

BW Technologies
BW Technologies MicroDock II Bedienungsanleitung

Sun Nuclear
Sun Nuclear 1027 Bedienungsanleitung

Biomark
Biomark HPR LITE READER Bedienungsanleitung

Hioki
Hioki 3169-20 Bedienungsanleitung

Ashcroft
Ashcroft ATE-100 Bedienungsanleitung