RECEIVING AND INSPECTION: If missing parts or damages are found, please notify the carrier at once
and insist on a notation of the damage on the bill of lading. DO NOT DISCARD THE SHIPPING BOX. If you
give the carrier a clear receipt for goods that have been damaged in transit, you do so at your own risk and
expense.
Table of Contents
Identifying Parts for Elite® Model 1
Identifying Parts for PrestigeTMModel 2
WALL CLEARANCE & SPA to SPA RECOMMENDED CLEARANCE 3
INSTALLATION OF PEDICURE SPA SEAT 3
INSTALLATION OF PLUMBING SYSTEM 5
INSTALLATION OF VENTILATION SYSTEM (OPTIONAL) 8
ELECTRICAL AND PEDICURE SPA COMPONENT SPECIFICATIONS 9
PRE-OPERATIONAL SETUP 10
OPERATE Auto-Fill™/Jet Switch: 12
OPERATE DIGITAL CONTROL PANEL(DCS) : 13
RESET WATER SENSOR AND WATER LEVEL 14
MASSAGE SYSTEM & REMOTE CONTROLLER 15
WARNING: 1. This Product is for indoor use only & is not recommended for use on Carpet or Wood floor
2. This Product must be connected to a circuit outlet protected by a Class A GFCI
3. DO NOT USE if you have poor circulation, or if any area of your feet or legs has an open sore
4. Maximum temperature of the water should never exceed 100 degrees F (38 C).
5. DO NOT STEP/ STAND IN THE FOOT BASIN.
6. NEVER bring and/or operate any electrical devices in or near the Pedicure Spa.
7. Maximum load in the spa chair is 250lbs (114kg).
PROPER INSTALLATION ACCORDING TO THIS MANUAL IS REQUIRED. FAILURE TO DO SO MAY RESULT IN SERIOUS
INJURY AND/OR WARRANTY WILL BE NULL. YOU MUST HAVE A LICENSED PLUMBER TO CONNECT THE SPA AND
WATER SYSTEM IN PLACE SAFELY.
STATES’ NOTICE
In the commonwealth of most states, all pedicure spas installed for Commercial usage are required to have a
backflow preventer at the salon’s cost. This device shall be installed between the water inlet hose and the spout.
PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

1
Identifying Parts for Elite® Model
z
Pedicure Spa with Massage System
Identifying Parts
IDENTIFYING PARTS
11.Ventilation Inlet
12. Air-Jet Connector
13. Liner Hook
14. Up/Down Armrest
15. Purse Hook
16. Manicure Tray
17. Drain Stopper
18. ECOJET™
19. Hand Spray Spout
20. Low Profile Pedicure Stool
1. Headrest
2. Chair Cushion with Massage
3. Armrest Cushion
4. Massage Remote Control
5. Aurora Bowl
6. Footrest with Calf Support
7. Digital control System(DCS)
8. Dual Function Auto-Fill™ &
Whirlpool Jet Switch
9. Hot/Cold Water Valve
10. Drain Switch

2
Identifying Parts for PrestigeTMModel
Pedicure Spa with Massage System
Identifying Parts
IDENTIFYING PARTS
1. Headrest
2. Chair Cushion with Massage
3. Armrest Cushion
4. Massage Remote Control
5. Aurora Bowl
6. Footrest with Calf Support
7. Digital Control System(DCS)
8. Dual Function Auto-Fill™ &
Whirlpool Jet Switch
9. Hot/Cold Water Valve
10. Drain Switch
11.Ventilation Inlet
12. Air-Jet Connector
13. Liner Hook
14. Up/Down Armrest
15. Purse Hook
16. Manicure Tray
17. Drain Stopper
18. ECOJET™
19. Hand Spray Spout
20. Low Profile Pedicure Stool

3
WALL CLEARANCE & SPA to SPA RECOMMENDED CLEARANCE
VERY IMPORTANT: Both the back of the chair and seat are adjustable. When the seat is at a maximum
incline, one must allow 18"(44cm) from the back wall to the foot spa. This minimum distance assures an
unobstructed recline. Failure to follow this required dimension might damage your spa components and
plumbing connections, which will void your warranty.
INSTALLATION OF PEDICURE SPA SEAT
1. FOLD & UNFOLD BACK-REST MASSAGE
INSTALLATION
Raise the backrest until a “click” is
heard. Make sure the lever is
locked before operating
To fold down the backrest: Lift up lever
handle and push the backrest downward

4
2. ASSEMBLE THE BACK AND SEAT CUSHION
3. ASSEMBLE THE ARM-RESTS
INSTALLATION
trench
Align the screws to the holes on the seat frame.
Put the seat cushion onto the frame. Then use
the provided screws to secure the seat.
Align the back cushion to fit on the back
shell. Push the cushion firmly onto the
VELCRO straps.
1) To install the armrest, position the armrest horizontally as shown above.
Align the rods and the notches as shown in Detail A and B. Fully snap-in the
armrest until hearing a “click” sound.
2) To remove the armrest, pull up the locking ring
as shown in figure and Detail C, then pull out the
armrest.

5
INSTALLATION OF PLUMBING SYSTEM
NOTE: The drainage and water supply system installation require a licensed plumber. Instructions and
local plumbing codes need to be carefully compiled to pass the city inspections.
1. GRAVITY DRAIN
1) The gravity drainage installation should comply with SECTION 701.0, 2018 UPC.
2) Trap, vent, and connectors should comply with SECTION 1001.1 and 1001.2 UPC.
3) An alternative code needs to be complied with by the states not adopting UPC.
a) Drainage system: SECTION 701.2 and 702.2 IPC (or local plumbing code)
b) Trap, vent, and connectors: SECTION 1002.1 and 1002.2 IPC (or local plumbing code)
4) The installer/plumber is responsible for obtaining and complying with the local plumbing code for
inspection. If any assistance is required from the vendor’s side, please contact our customer
service.
PLUMBING SYSTEM

6
2. POWER DRAIN
1) The power drainage installation should comply with SECTION 807.1, 2018 UPC.
2) Trap, vent, and connectors should comply with SECTION 1001.1 and 1001.2 UPC.
3) An alternative code needs to be complied with by the states not adopting UPC.
a) Drainage system: SECTION 701.2 and 702.2 IPC (or local plumbing code)
b) Trap, vent, and connectors: SECTION 1002.1 and 1002.2 IPC (or local plumbing code)
4) The installer/plumber is responsible for obtaining and complying with the local plumbing code for
inspection. If any assistance is required from the vendor’s side, please contact our customer
service.
PLUMBING SYSTEM

7
3. DRAINAGE SYSTEM RECOMMENDATION
4. HOT/CODE WATER SUPPLY SYSTEM
NOTE: The drainage and water supply system installation require a licensed plumber. Detailed
instructions can be found in the manual book. Instructions and local plumbing codes need to be
carefully compiled to pass the city inspections.
New constructions: drain a good amount of water in
a bucket to remove all debris from the new hot/cold
water pipes before connecting to new SPA chairs
(figure 1).
Replacement Spas: Make sure to use new hot/cold
water hoses to replace old ones before installing a new
Spa chair. The old debris, rubber, or plastic chips could
clog the water inlet system.
** Failure to do so will invalidate the warranty.
Figure 1. Drain water to remove
debris before installing new spa chair.
PLUMBING SYSTEM

8
INSTALLATION OF VENTILATION SYSTEM (OPTIONAL)
(The Spa comes with a preinstalled ventilation system to fulfill the regulations for some states. Please
contact your state department for the requirements and regulations)
VENTILATION
Andere Handbücher für ELITE
1
Dieses Handbuch passt für folgende Modelle
4
Inhaltsverzeichnis
Andere Lexor Pediküre Spa Handbücher

Lexor
Lexor Q-SPA Bedienungsanleitung

Lexor
Lexor PRIVE PEDICURE SPA Bedienungsanleitung

Lexor
Lexor ULTIMA Bedienungsanleitung

Lexor
Lexor PRIVE LOUNGE Bedienungsanleitung

Lexor
Lexor VERSAS Bedienungsanleitung

Lexor
Lexor LIBERTE Bedienungsanleitung

Lexor
Lexor ELITE Bedienungsanleitung

Lexor
Lexor PRIVE Bedienungsanleitung