HID-115S-V-EX39-8TW-BYP/LCBR
Field-Adjustable High Bay
Lightcloud
with 5-Pin Lightcloud Blue Port

Hello
Lightcloud Blue is a Bluetooth mesh wireless lighting control
system that allows you to control RAB’s various compatible
devices. With RAB’s patent-pending Rapid Provisioning
technology, devices can be quickly and easily commissioned
for residential and large commercial applications using the
Lightcloud Blue mobile app. Each device in a system can
communicate with any other device, eliminating the need for
a Gateway or Hub and maximizing the control system’s reach.
Product Features
Wireless control from your mobile device*
On/o and dimming
Wireless remote control*
Direct Connect LED, No Gateway or Hub required
Create custom scenes
Catalog Number:
HID-115S-V-EX39-8TW-BYP/LCBR
HID-115S-V-EX39-8TW-BYP/LCBR
Model Number:
Construction:
Lamp Base: EX39
Electrical:
60W/80W/115W,
7800lm/10400lm/14950lm,
120-277Vac, 50/60Hz
*Requires Lightcloud Blue Plug-In Controller
Sensor compatible
SmartShift™ automated circadian schedule*
Schedules and automations

Safety Information
• Not suitable for use with standard dimmers and sensors unless
specically designed for RAB Lightcloud Blue Lamps.
• Do not use where directly exposed to water.
NOT FOR EMERGENCY LIGHTING. ADDED WEIGHT OF THE DEVICE MAY
CAUSE INSTABILITY OF A FREE-STANDING. PORTABLE LUMINAIRE. USE
ONLY WITH A PORTABLE LUMINAIRE THAT IS PROVIDED WITH A SHADE.
• Only install in operating environments between -22°F and 140°F (-30°C
to 60°C). Only use the control provided with or specied by these
instructions to control this lamp. This lamp will not operate properly
when connected to a standard (incandescent) dimmer or dimming
control. CAUTION - RISK OF ELECTRIC SHOCK. Do not use if outer lamp
envelope is damaged or broken.
• WARNING - Risk of re or electric shock. LED Retrot Kit installation
requires knowledge of luminaires electrical systems. If not qualied, do
not attempt installation. Contact a qualied electrician.
• WARNING - Risk of re or electric shock. Install this kit only in luminaires
that have the construction features and dimensions shown in the
photographs and/or drawings and where the input rating of the retrot
kit does not exceed the input rating of the luminaire.
• Do not make or alter any open holes in an enclosure of wiring or
electrical components during kit installation.
• WARNING - To prevent wiring damage or abrasion, do not expose
wiring to edges of sheet metal or other sharp objects.
• THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE
WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED
BY AUTHORITIES HAVING JURISDICTION. PRODUCT MUST BE INSTALLED
BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE APPLICABLE
AND APPROPRIATE ELECTRICAL CODES.
THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR NATIONAL
REGULATIONS FOR ELECTRICAL INSTALLATIONS.

Installing your Lightcloud Blue Lamp
1
Lightcloud Blue APP
<=60 ft.
DRYWALL
OR SIMILAR
Add an additional
Lightcloud Blue Device
to extend network range
around corners
BRICK, CONCRETE,
OR METAL WALL
Find a suitable location
Turn o power
OFF
OFF
WARNING
• Place the wall switch in the o position.
• Lightcloud Blue devices should be positioned within
60 ft. of each other.
• Building materials such as brick, concrete and steel
construction may require additional Lightcloud Blue
devices to extend around an obstruction.
• Turn o the main power at the breaker
panel or remove the fuse from the fuse box.
2

Installing your Lightcloud Blue Lamp
(cont’d)
Install the Lightcloud Blue Lamp
• Remove old ballast or disconnect from existing
lampholder. Remove and dispose of ballast in correct
manner. Shown as Figure 1. (North America 120-277VAC)
3
AC 120-277V
Capacitor
Ballast
Ignitor
• Reconnect directly to the existing lampholder.
Shown as Figure 2. (North America 120-277VAC)
AC
120-277V
Lampholder

Installing your Lightcloud Blue Lamp
(cont’d)
• Select power and CCT of new LED replacement lamp
before installation.
• Install new LED replacement lamp. Shown as Figure 3.
Please make sure the old tting is correctly earth. Attach
retrot label to luminaire. (North America 120-277VAC)
• Securely fasten the earth y lead cable to the main body
structure. If the cable are damaged in any way please
replace. (Do not use existing burnt out cables)
The cable if need replacement must be 1.0mm in size
and insulated from heat.
AC
120-277V
Power and CCT Selectable
4
Power Selectable
Switch
Color Selectable
Switch
80W
60 W 115 W

Installing your Lightcloud Blue Lamp
(cont’d)
Connect device to power.
Remove plastic plug from lamp, then insert
Lightcloud Blue Plug-In Controller into interface.
For rst time use, the lamp will be ready to pair to
the Lightcloud Blue app. Power on the lamp to enter
pairing mode. While pairing, the lamp will ash on/o
5x and then dim and ash on/o 3x to indicate that it
has been paired as an Ungrouped Device in the
Lightcloud Blue app.
5
5a
5b
Plastic Plug
Lightcloud Blue
Lamp
Lightcloud Blue
Plug-In Controller

Safety Cable Installation Instruction
You must use the safety cable to tight the lamps
in case of falling down due to old socket.
1
Take out the safety
cable we put in box
2
Fix the safety cable one
end through the hole
3
Fasten the other end
on the luminaire

Controlling your Lightcloud
Blue Device
Conrm your device is powered on.
1
2
3
4
5
6
Download the Lightcloud Blue app from the Apple®
App Store or Google® Play store.
Tap the "add device" icon in the app to
start connecting devices.
Follow the remaining steps in the app. Create areas,
groups, and scenes to organize and control your devices.
You're all set!
Launch the App and create an account.

To restore your Lightcloud Blue Field-Adjustable High Bay to
factory settings, use the following methods.
Setting Device to Pairing Mode
Method 1:
Delete from App
Open the app and access the device settings for the paired
device. Be sure that the lamp is online and select "Delete".
Lightcloud
Method 2: Manual
Power the lamp o and on 5 times consecutively.
Do not allow less than 1 second and more than
10s elapse before switching o and keep o for
at least 3s before switching on. The lamp will
ash 3 times, then reset to 100% brightness at
default CCT.
Method 3: Rapid Reset Tool
The rapid reset process must be done by professional
electricians qualied by RAB. Reach out to your
RAB sales manager to request a Rapid Reset Tool.
The tool simply needs to be placed directly on
the Lightcloud Blue Plug-In Controller for
2 seconds. The lamp will ash 3 times, then
reset to 100% brightness at default CCT.
5
X
Inhaltsverzeichnis
Andere Lightcloud Arbeitsleuchte Handbücher
Beliebte Arbeitsleuchte Handbücher anderer Marken

PowerSmith
PowerSmith PWLD080T Bedienungsanleitung

MaxLite
MaxLite 73683 Bedienungsanleitung

Heitronic
Heitronic Trend 27867 Bedienungsanleitung

Monzana
Monzana Gore MZCL10 Bedienungsanleitung

EINHELL
EINHELL TE-CL 18/2000 LiAC Bedienungsanleitung

Bayco
Bayco NIGHTSTICK Dual-Light Xtreme Lumens... Bedienungsanleitung