Page 5 of 10
SR516D DMX REMOTE STATION
Version 1.20 OWNERS MANUAL 07/06/2020
www.lightronics.com
Lightronics Inc. 509 Central Drive, Virginia Beach, VA 23454 757 486 3588
33 Simple Switch Input #1 Options
34 Simple Switch Input #2 Options
35 Simple Switch Input #3 Options
36 Not Used
37 System Configuration Options 1
38 System Configuration Options 2
41 Mutually Exclusive group 1 scene selection
42 Mutually Exclusive group 2 scene selection
43 Mutually Exclusive group 3 scene selection
44 Mutually Exclusive group 4 scene selection
88 Factory Reset - Invokes a default configuration
A diagram at the back of this manual gives a quick
guide to programming the unit.
RECORD BUTTON
This is a very small recessed pushbutton in a small
hole in the faceplate. It is just below the RECORD
LED (labeled REC). You will need a small rod (such
as a ball point pen) to push it.
ACCESSING AND SETTING FUNCTIONS
1. Hold down REC for more than 2 seconds. The
REC light will begin blinking.
2. Push RECALL. The RECALL and REC lights
will blink alternately.
3. Enter a 2 digit function code using the scene
buttons (1 - 8). The scene lights will flash a
repeating pattern of the code entered. The unit
will return to its normal operating mode after
about 60 seconds if no code is entered.
4. Push RECALL. The RECALL and REC lights
will be ON. The scene lights (in some cases
including the OFF (0) and BANK (9) lights) will
show the current function setting or value.
Your action now depends on which function was
entered. Refer to the instructions for that function.
You can enter new values and push REC to save them
or push RECALL to exit without changing the values.
SETTING FADE TIMES (Function Codes 11 - 32)
The fade time is the minutes or seconds to move
between scenes or for scenes to go ON or OFF. The
fade time for each scene can be individually set. The
allowable range is from 0 seconds to 99 minutes.
Fade time is entered as 4 digits and can be either
minutes or seconds.
Numbers entered from 0000 - 0099 will be recorded
as seconds.
Numbers 0100 and larger will be recorded as even
minutes and the last two digits will not be used. In
other words seconds will be ignored.
After accessing a function (11 - 32) as described in
ACCESSING AND SETTING FUNCTIONS:
1. The scene lights + OFF(0) and BANK(9) lights will
be flashing a repeating pattern of the current fade
time setting.
2. Use the scene buttons to enter a new fade time (4
digits). Use OFF for 0 and BANK for 9 if needed.
3. Push REC to save the new function setting.
Function Code 32 is a master fade time function
which will set ALL fade times to the value entered.
You can use this for a base setting for fade times and
then set individual scenes to other times as needed.
SIMPLE REMOTE SWITCH BEHAVIOR
The SR516 is very versatile in how it can respond to
the simple remote switch inputs. Each switch input
can be set to operate according its own settings.
Most settings pertain to momentary switch closures.
The MAINTAIN setting allows the use of a regular
ON/OFF switch. When used this way, the applicable
scene(s) will be ON while the switch is closed and
OFF when the switch is open.
Other scenes can still be activated and the OFF button
will turn off the MAINTAIN scene OFF.
SETTING SIMPLE SWITCH INPUT OPTIONS
(Function Codes 33 - 35)
After accessing a function (33 - 35) as described in
ACCESSING AND SETTING FUNCTIONS:
1. The scene lights including OFF(0) and BANK(9)
will flash a repeating pattern of the current
setting.
2. Use the scene buttons to enter a value (4 digits).
Use OFF for 0 and BANK A/B for 9 if needed.
3. Push REC to save the new function value.