lmp LiNKTEMP Bedienungsanleitung

L NKTEMP
TM
Non-contact
Infrared Thermometer
User Manual
LMP001

Product Description
Intended Use
Product Features
Safety Precautions
Using the Thermometer
Taking a Measurement
Temperature Mode
Temperature Unit
Viewing Data Memory
Deleting Data Memory
Setting Alarm Temperature
Audio Setting
High Temperature Alarm
Low Battery Detection
Changing the Battery
Technical Specications
Product Maintenance
Cleaning and Disinfecting Instructions
Accessories Included
Guidelines and Compliance
Classication
Troubleshooting
Symbol References
TABLE OF CONTENTS
THE MANUFACTURER RESERVES THE RIGHT TO
ALTER THE SPECIFICATIONS OF THE PRODUCT
WITHOUT PRIOR NOTIFICATION.
1
1
1
1
3
4
5
6
6
6
7
7
7
8
8
9
10
10
12
12
12
12
16

Product Description
LinkTemp™ is a professional grade thermometer that measures body
(forehead), surface and room/ambient temperature instantly and
accurately. The LinkTemp Non-contact Infrared Thermometer can be
used as a non-invasive screening tool in a multi-patient environment.
Intended Use
LinkTemp is a non-contact, infrared thermometer intended to
measure forehead temperature in a professional healthcare
environment.
Product Features
• Infrared sensor accurately reads body temperature 1.2” to 2”
(3 to 5 cm) from forehead
• Large, 2-color LCD
• Stores the last 32 temperature readings
• Audible voice function (English & Spanish)
• Visual/audible alarm for high temperature readings
• Temperature displays in either Fahrenheit or Celsius
• Performs up to 100,000 readings
Safety Precautions
Follow the maintenance advice specied in this instruction manual.
• This device must only be used for the purposes described in this
instruction manual.
1

• This device must only be used in an ambient temperature range of
between 50˚F - 104˚F (10˚C - 40˚C).
• Always keep device in a clean, dry area.
• Do not expose the thermometer to electric shocks.
• Do not expose the thermometer to extreme temperature
conditions.
• Do not use this device in relative humidity higher than 85%.
• Do not touch the infrared sensor glass with your ngers.
• Clean the infrared sensor glass with a cotton swab lightly moistened
with 90% isopropyl alcohol.
• Follow the manufacturer’s recommended cleaning and disinfecting
instructions.
• Do not expose the thermometer to sunlight or to water.
• Do not drop the thermometer.
• Do not attempt to repair this device yourself.
• The device is not suitable for use in the presence of ammable
anesthetic mixtures with oxygen or nitrous oxide.
• The device does not require calibration.
• The device is not repairable and contains no user serviceable parts.
• Modication of the thermometer is prohibited and will invalidate
the warranty.
• Remove batteries if thermometer will not be used for a long period
of time.
• Check that the thermometer functions safely and is in proper
working condition before each use.
• Contact the manufacturer for assistance or reporting.
• Keep the thermometer out of reach of children and pets.
2

The LinkTemp Non-contact Infrared Thermometer is pre-set
at the factory.
It is not necessary to calibrate the device when starting it up.
However, in order to obtain reliable results, you are advised to allow
the thermometer to acclimate to room/ambient temperature for 15
to 20 minutes before using each time there is a signicant change in
environmental temperature. It is also important to allow a 3 to 5
second intervals between measurements.
Using the Thermometer
Audio On/O
(English/Spanish)
2-color LCD
(Blue & Red)
Memory
MODE
ON/SCAN
Lanyard
3

Fig.1
Taking a Measurement
1. Press ON/SCAN button to power on the thermometer. When the
devise is ready, the LCD screen will turn blue.
2. Position the thermometer between 1.2” to 2” (3 to 5 cm) from the
patient’s forehead. (Fig.1)
NOTE: Move hair out of the way before taking a measurement.
NOTE: If the forehead area is or has been covered with sweat,
makeup or a hat, rst clean and dry the forehead area
before taking a measurement.
Taking a Measurement
Taking a Measurement
Surface Temp Mode
Body Temp Mode
Room Temp Mode
Celsius
Fahrenheit
Memory
Low Battery
Indicator
Audio ON
(English or Spanish)
Temperature
Display Value
Measurement distance
from forehead is 1.2” - 2“
Target area for
measurement
4

3. Press ON/SCAN button to take measurement.
4. A measurement will be displayed on the LCD screen.
• To repeat the process, return to step 2.
• Allow 3 to 5 seconds between measurements.
5. The thermometer automatically turns o after 30 seconds of
inactivity.
Temperature Mode
The
LinkTemp Non-contact Infrared Thermometer can take body,
surface or room/ambient temperature.
1. While the thermometer is turned on, press the MODE button to
toggle through the three temperature mode options - BODY,
SURFACE or ROOM.
NOTE: When rst using the thermometer, the default is set to
BODY mode.
NOTE: Measurement ranges for each temperature mode are as follows:
BODY mode: 89.6˚F to 109˚F (32˚C to 42.9˚C)
SURFACE mode: 32˚F to 140˚F (0˚C to 60˚C)
ROOM mode: 32˚F to 104˚F (0˚C to 40˚C)
NOTE: Once the thermometer is powered on, the last temperature
mode measured will default as the current temperature mode.
NOTE: Always use the BODY mode to measure core body temperature.
5

Temperature Unit
While the thermometer is turned on, press the MODE and the
buttons at the same time for 3 seconds, the screen will display F-1.
Select the button for Celsius and MODE button for Fahrenheit.
Conrm by pressing MEM button. Then to exit the setting, press MEM
button quickly two times.
NOTE: The LinkTemp Non-contact Infrared Thermometer default
setting is Fahrenheit.
Viewing Data Memory
1. While the thermometer is turned on, press MEM button, which will
display the last temperature reading.
2. Press MEM button again to see the next reading stored of the last
32 measurements taken.
3. To exit data memory mode, press ON/SCAN button to go to
measurement mode or wait 30 seconds for thermometer to
automatically turn o.
Deleting Data Memory
1. While the thermometer is turned on, press MEM button for 3 seconds
to delete all data in memory.
2. When data memory is deleted you will see CLR on the screen.
3. To exit deleting data memory mode, press ON/SCAN button to go to
measurement mode or wait 30 seconds for thermometer to
automatically turn o.
2. Press MEM button again to see the next reading stored of the last
6

Setting Alarm Temperature
1. While the thermometer is turned on, press the MODE and the
button at the same time for 3 seconds. The screen will display F-1.
2. Press the MEM button one additional time to get F-2. Select MODE
button to add 0.1˚F or 0.1˚C. Select the button to minus 0.1˚F
or 0.1˚C.
3. Conrm by pressing MEM button.
4. Exit the setting by pressing MEM button again.
NOTE: For temperature unit Fahrenheit, the alarm range is 96.8˚F to
109.2˚F. If the temperature unit is Celsius, the alarm range is
36˚C to 42.9˚C.
NOTE: High temperature alarm default setting is 100.4˚F (38˚C).
Audio Setting
Press the button to choose audio language type or to shut
audio o.
1. While the thermometer is turned on, press the button to toggle
between English (EN), Spanish (SP) and audio o (OFF).
2. To exit audio setting, press ON/SCAN button to go to measurement
mode or wait 30 seconds for thermometer to automatically turn o.
High Temperature Alarm
BODY mode
1. If the temperature taken is less than the setting alarm value, the
buzzer sends out 1 sound and reports the current temperature in a
blue backlit screen. When the temperature is more than or equal to
the setting alarm value, the buzzer sends out 5 sounds and reports
7

the current temperature in a red backlit screen.
NOTE: High temperature alarm default setting is 100.4˚F (38˚C).
NOTE: When operating the thermometer in a room/ambient
temperature less than 50˚F (10˚C) or more than 104˚F (40˚C),
the BODY and SURFACE temp modes will display an ERR1
message and send out 2 sounds in a blue backlit screen.
Low Battery Detection
If the battery voltage is not more than 2.7V, the LinkTemp Non-contact
Infrared Thermometer will display the ashed symbol to remind
you to replace both batteries.
Changing the Battery
The LinkTemp Non-contact Infrared Thermometer comes with 2 AA
alkaline batteries. When the LCD screen displays , both batteries
should be replaced. Open the lid on the underside of the thermometer
and replace the batteries, taking great care with the correct battery
positioning. (Fig.2)
Temp Non-contact Infrared Thermometer comes with 2 AA
alkaline batteries. When the LCD screen displays , both batteries
should be replaced. Open the lid on the underside of the thermometer
and replace the batteries, taking great care with the correct battery
Temp Non-contact Infrared Thermometer comes with 2 AA
Fig.2
8