Logic Controls LS6000 Bedienungsanleitung

Logic Net eStation
Kitchen Video Controller with Ethernet Interface
USER MANUAL AND
INSTALLATION GUIDE
LS6000

i
NOTICE
The manufacturer of the Industrial Computer makes no representations or warranties, either
expressed or implied, by or with respect to anything in this manual, and shall not be liable for
any implied warranties of fitness for a particular purpose or for any indirect, special or
consequential damages. Information in this document is subject to change without notice and
does not represent a commitment on the part of the manufacturer.
FCC NOTICE
This device complies with Part 15 of FCC Rules. Operations are subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
EUROPEAN COMMUNITY (CE) MARK OF CONFORMITY
This product is in conformity with the protection requirements of EU Council Directive
89/336/EEC on the approximation of the laws of the Member States relating to
electromagnetic compatibility. Logic Controls cannot accept responsibility for any failure to
satisfy the protection requirements resulting from a non-recommended modification of the
product. This product has been tested and found to comply with the limits for Class A
Information Technology Equipment according to CISPR 22 / European Standard EN 55022.
The limits for Class A equipment were derived for commercial and industrial environments to
provide reasonable protection against interference with licensed communication equipment.
Warning:
This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
LOGIC CONTROLS, INC.
355 Denton Ave
New Hyde Park, NY 11040
TEL: (516) 248-0400
FAX: (516) 248-0443
http://www.logiccontrols.com

ii
IMPORTANT SAFETY INSTRUCTIONS
Please read the following instructions carefully and save these instructions for future
reference.
1. Follow all warnings and instructions for installation and operation of the product.
2. Unplug this product from the wall outlet before cleaning. Use only mild cleaning
agents and do not immerse in water.
3. Do not use this product near water.
4. This product should be operated from the type of power indicated on the power
adaptor. If you are not sure of the type of power available, consult your dealer or local
power company.
5. Do not allow anything to rest on the power cord. Do not locate this product where
persons will walk on the cord.
6. If an extension cord is used with this product, make sure that the total ampere rating of
the equipment plugged into the extension cord does not exceed the extension cord
ampere rating. Also, make sure that the total rating of all products plugged into the
wall outlet does not exceed the fuse rating.
7. We recommend all servicing done on this product be done by qualified service
personnel. Aside from upgrades or swapping out the compact flash please refer all
other servicing to the Logic Controls RMA Dept or a repair provider that has been
certified by Logic Controls.
8. Unplug this product from the wall outlet and refer servicing to qualified service
personnel under the following conditions:
a) When the power cord or plug is damaged or frayed
b) If liquid has been spilled into the product
c) If the product has been exposed to rain or water
d) If the product does not operate normally when the operating instructions are
followed. Adjust only those controls that are covered by the operating
instructions since improper adjustment of other controls may result in damage
and will often require extensive work by a qualified technician to restore the
product to normal condition.
e) If the product has been dropped or the cabinet has been damaged
f) If the product exhibits a distinct change in performance, indicating a need for
service.

iii
TABLE OF CONTENTS
FEATURES .........................................................................................................1
PRODUCT DESCRIPTION..................................................................................3
CONNECTOR PINOUTS.....................................................................................5
HARDWARE INSTALLATION ............................................................................6
LS6000 SETUP AND SELF-DIAGNOSTIC TESTS ............................................7
SYSTEM SETUP ...............................................................................................10
TROUBLE SHOOTING .....................................................................................11
SOFTWARE DEVELOPMENT ..........................................................................13
SPECIFICATIONS.............................................................................................14

1
FEATURES
The LS6000 Logic Net eStation is the Ethernet version of Logic Net, the industry’s leading
kitchen video display system solution. It has succeeded the advantages of Logic Net and yet
facilitates network implementation with the most popular Ethernet connections.
» Highly Reliable
• No complex PC work stations
• Low power operation, low internal temperature rise
• Simple hardware and no disk drive (no moving parts)
• Reliable latched interface connections
• Rugged die-cast housing
• Standard Ethernet network connection
• Stable operation, no computer crashes, viruses, and lockups
• Tamper proof, no on/off and option switches, no adjustable devices
» Low Cost
• PC workstations NOT required
• Network software NOT required
• Network cards NOT required
• I/O expansion hardware NOT required
• Simplified installation and setup
» Advanced Operations
• 256 text foreground and background color
• Icon display continuously showing connection status of Ethernet and keyboard
• Touch-screen support
• Status line display for showing status, messages, help items, alerts, or on-screen touch
function keys (with touch screen support enabled).
• Beep tone pitch controllable in command such that each station can beep with different
pitch for easier identification
• 16 automatic timers individually displayable at any location on the screen
• 4 display modes (40-column, 60-column, 80-column and 106-column)
• Display bit-map files for build-card display support
» Embedded Custom Functions
• Embedded custom functions available through downloadable firmware upgrade
• Executes complex sequence of operations with a single command from the server
• Reduces application software burden
• Performs real-time tasks more efficiently for enhanced system throughput
» Small Size
• Module size: 6.3"W x 5.1"L x 1.0"H (160 x 130 x 25mm)
• Flexible Installation: Table Mount, Wall Mount, Display Bracket Mount, and Under-the-
Counter Mount
» Highly Secure
• Designed to prevent illegal data copying through externally accessible removable media.
The internally installed compact flash (optional) is for picture storage. Program code and
data are not stored in the compact flash.
• Enhanced security through proprietary command set
• Immune to viruses

2
» Minimize Obsolescence Problems
• Upgrade LS6000 units with remote downloadable firmware and character fonts
» Extensive Free Software Development Support
• High-level language software utilities allow developers to write application software with
Visual Basic or Visual C++
• OCX control covers all of the Logic Net's command sets
• Multi-tasking programs are supported
• Command test program with source code to illustrate the applications of the command set
• Source code of mini-applications to answer all how-to-write questions
• Free phone and e-mail technical support
» Self-diagnostic
• Automatic power-on and diagnostic tests for:
- Internal Memory
- Communication Integrity
- Keyboard Connection
- RS232 ports
- Internal Beeper
» Compatible OS
• Compatible with servers operating in:
- DOS
- Linux
- Unix
- Windows 95/98/ME
- Windows NT/2000/XP
» International Operations
• Downloadable code pages support languages for international operations
• Universal input (100 to 240VAC, 47 to 63Hz) switching power supply

3
PRODUCT DESCRIPTION
A typical system consists of a host server (PC or POS terminal) where the application
software is installed and a number of LS6000 Logic Net eStation units. Each LS6000 unit can
be connected to a VGA monitor, a keyboard, and 2 serial interface devices. The LS6000
units communicate with the host server via TCP sockets on Ethernet connections. Logic Net
commands are sent from the server to display data on the eStation VGA monitor and to read
key codes of keys entered on the keyboard.
RESET Button
Press the RESET button located on the front of the LS6000 to reset the unit and access
Setup or self-diagnostic tests.
Power/Status LED
The power/status LED is located on the front of the LS6000. A light indicates that power is
ON. When communicating with the host server, the LED will blink.
Speaker/Beeper
The beeper function is controlled by host software applications. The frequency of the beeper
tone can be adjusted from the LS6000 Setup screen.
Keyboard
An RJ-11 to PS2 adapter will connect the LS6000 to a standard PC keyboard. Other
keyboard wedge interface input devices such as Bumpbars, Bar-Code Scanners or Magnetic
Stripe Readers can also be connected to the LS6000. The Logic Controls KB1700 Bumpbars
are specially designed for use in the kitchen. Refer to the KB1700 manual for more
information on the bumpbar.
Displays: Monochrome or Color VGA
LS6000 supports any standard color or monochrome VGA CRT or LCD display using a
standard 15-pin DSUB VGA connector.
RS-232 Devices
The two auxiliary RS-232 ports on the LS6000 supports connections to serial printers, touch
screens*1, barcode scanners, and other serial interface I/O devices. The first serial port is a
standard 9-pin DSUB connector. The second port is an RJ45 connector with EIA-561 pin out.
Power Requirements
The power supply for LS6000 is same as the one used for LM3000 and LS3000. The power
supply is designed for single-phase, sinusoidal ac operation and accepts a wide input range

4
that does not require intervention to change between low- and high-voltage AC. Operation at
any voltage within these ranges will meet the output requirements and will not cause damage
to the supply. The power supply output is connected to the LS6000 with locking connectors.
Nominal Voltage: 100–240 V AC
Voltage Variation: 90–265 V AC
Frequency: 47–63 Hz
*1 - Custom driver code in firmware is required for supporting different models of touch
screens and will be available in future versions of LS6000. Currently, Elo touch
screens are supported.

5
CONNECTOR PINOUTS
Ethernet interface (8 pin RJ45 connector with 2 LED indicators)
1 TX-
2 TX+
3 RX-
6 RX+
RS-232 interface (9 pin DSUB male connector)
1 DCD
2 RX
3 TX
4 DTR
5 GND
6 DSR
7 RTS
8 CTS
RS-232 interface (8 pin RJ45 connector – EIA-561 pin out)
1 DSR
2 DCD
3 DTR
4 GND
5 RXD
6 TXD
7 CTS
8 RTS
Keyboard interface (6 pin RJ-11 connector)
1 CLK
2 DATA
3 No connection
4 Signal GND
5 +5 V dc
6 Chassis GND
VGA interface (15 pin DSUB female connector)
1 Red
2 Green
3 Blue
5,6,7,8 &10 GND
13 H-Sync
14 V-Sync
DC Power (Shielded snap lock mini-DIN connector with EMI/RFI suppression)
5 +5 V dc
8 +5 V dc
3 GND
6 GND
1 5
6 9

6
HARDWARE INSTALLATION
Component Placement
The following is recommended when you plan the Logic Net setup:
•Place the LS6000 so that you can use the mounting brackets located at the bottom of
the unit.
•Place the LS6000 so that the RESET button is accessible.
•Place the LS6000 so that the beeps from the speakers can be heard.
•Place the LS6000 so that the LED indicator on the front panel can be seen.
•Place the LS6000 above grill/counter level, out of the way of possible spills.
Mounting Instructions
Mounting brackets are provided to facilitate mounting the LS6000 to a wall, ceiling or display
monitor mounting arm. The installer should insure that the wall anchors used with the
mounting brackets have the capacity to support 4.3 kg (9.5 lb.). This weight is determined by
adding a safety margin weight to the weight of the unit. Wall anchors with specified weight
capacity are available commercially.
Connections
Make sure that all systems are powered off before making or removing any connections to the
LS6000 unit. Follow the steps below in connecting the devices:
1. Connect the VGA cable of the display monitor to the LS6000.
2. Connect the RS232 cable of serial devices to the LS6000.
3. Connect the keyboard device to the LS6000.
4. Connect the Ethernet cable from Ethernet hub or switch to the LS6000.
5. Connect power to all peripheral devices and turn on power.
6. Connect power adapter to the LS6000 and power cord to the power adapter.
7. Plug the power cord into AC power outlet.
8. If necessary, reset the LS6000 by pressing the reset button.
Andere Handbücher für LS6000
1
Inhaltsverzeichnis
Andere Logic Controls Controller Handbücher