LTi Drives S Series Bedienungsanleitung

Operation Manual
SMARTDRIVE VF1000 · Series S
Frequency Inverter 0.375 to 0.75 W
EN
stop
return start
enter
VAL
Hz
SMART
CARD
X5 X1

Operation Manual
for static
frequency inverter
1 x 110 V - Version
VF1104S - 375 W
1 x 230 V - Version
VF1202S - 375 W
VF1204S - 750 W
3 x 400 V - Version
VF1402S - 750 W
Applies as from software edition V1.6
ID No.: 0720.21B.2 - 03
Issued: Sep. 2008

A-1
Dear customer!
Thank you for the trust which you have placed in us at LTi Drives GmbH
by purchasing the SMARTDRIVE frequency inverter.
Installation and commissioning should be carried out by a trained engineer.
Please take the time to read this Operation Manual carefully before starting
work. If you follow all the instructions, you will save yourself much time
and many questions during the commissioning stage.
It is essential to read this Operation Manual because both the inverter
itself and further components of the system can be damaged by improper
handling.
If after reading the manual, however, you still have questions, do please
contact us as given below.
LTi Drives GmbH
Gewerbestr. 5-9
D-35633 Lahnau
Phone: +49 64 41 966 -0
Fax: +49 64 41 966 -137

A-2
A Useful information on the Operation Manual
The details in this manual apply for all frequency inverters belonging to
the SMARTDRIVE VF1000S family of devices.
The Information Manual is made up of 6 chapters that are listed under the
heading “Signposts to Success”.
Section A contains information on device variants and safety instructions.
Chapters 1, 2 and 3 are of importance with regard to commissioning.
Chapters 4, 5 and 6 refer to the operation of the inverter with the KEYPAD
operating device and provide information on the individual parameters.
To meet client requirements for frequency inverters, there are a
number of different versions with special functions. Version
information which differs from standard is noted in the option
descriptions.
For the sake of clarity, the following symbols are used to identify warnings
and important advice.
⇒Caution: Danger of death by electrocution.
⇒Caution: It is essential that you follow these instructions.
⇒Caution: Disconnect device from mains and wait 2 minutes to allow the
DC link capacitors to discharge.
⇒Prohibited: Incorrect operation may cause damage to equipment.
⇒Useful information, tip.
⇒Setting with the KEYPAD is alterable.
stop
return start
enter
Wait 2 mins after
disconnecting

A-3
Signposts to Success
A Useful information on the
Operation Manual ......................................................... A-2
A.1 Safety instructions ...........................................................A-5
A.2 Intended use....................................................................A-5
A.3 Model and accessories....................................................A-7
A.4 Manufacturer´s declaration for frequency inverters .........A-8
A.5 VF1000 S series with CE official acceptance.................A-12
A.6 Information concerning installation in accordance
with EMC regulations.................................................... A-16
1 Technical data................................................................ 1-1
1.1 Design and layout............................................................ 1-1
1.2 Data table........................................................................ 1-2
1.3 Cooling ............................................................................ 1-4
1.4 Dimensional diagrams ..................................................... 1-4
1.5 Installation ....................................................................... 1-7
2 Electrical connections .................................................. 2-1
2.1 Connection plan .............................................................. 2-1
2.2
Emitted interference/immunity to interference (EMC) ............... 2-4
2.3 Power connections .......................................................... 2-5
2.3.1 Mains connection ............................................................ 2-5
2.3.2 Motor connection............................................................. 2-6
2.3.3 Length of motor cable...................................................... 2-7
2.3.4 PTC thermistor connection .............................................. 2-7
2.3.5 Braking chopper connection ............................................ 2-8
2.4 Control connections......................................................... 2-9
2.4.1 Specifications .................................................................. 2-9
2.4.2 Function of the FSINA reference value input ................. 2-10
2.4.3 Control functions using STR/STL .................................. 2-12
2.4.4 Control function using S1IND/S2IND ............................. 2-13
2.4.5 MOP function with S1IND/S2IND .................................. 2-15
2.4.6 Signal outputs................................................................ 2-19
2.4.7 LUSTBUS connection ....................................................... 2-21
2.4.8 Frequency reference as PWM-signal (I1, I6, I7) ............ 2-23
3 Operation and fault diagnostics.................................. 3-1

A-4
3 Operation and fault diagnostics................................... 3-1
3.1 Operation indicators ........................................................ 3-1
3.2 Error messages ............................................................... 3-1
3.2.1 Error messages with device response............................. 3-1
3.2.2 Warningmessages.......................................................... 3-2
3.3 Motor/inverter overload protection (I*t monitoring) ........... 3-3
4 Using the KP100 KEYPAD ............................................... 4-1
4.1 Layout ............................................................................. 4-1
4.2 General ........................................................................... 4-2
4.2.1 Menu options................................................................... 4-2
4.2.2 Key functions................................................................... 4-2
4.2.3 LCD display ..................................................................... 4-3
4.3 Menu structure ................................................................ 4-4
4.3.1 Overview ......................................................................... 4-4
4.3.2 MOP- function (motor operated potentiometer) ............... 4-6
5 Parameter list................................................................. 5-1
5.1 Level 1............................................................................. 5-1
5.2 Level 2............................................................................. 5-2
5.3 Inverter-dependent and country-related parameters........ 5-4
6 Description of parameters ............................................ 6-1
6.1 Reference value selection ............................................... 6-1
6.2 Actual values ................................................................... 6-5
6.3 Frequencies .................................................................... 6-7
6.4 Ramps............................................................................. 6-8
6.5 Characteristics ................................................................ 6-9
6.6 Special functions ............................................................6-11
6.7 Signal outputs................................................................ 6-16
6.8 Program functions ......................................................... 6-17

A-5
A.1 Safety instructions
While in operation, inverter surfaces can be conductive, uninsulated,
sometimes also moving or rotating, and hot – depending on the degree to
which they are protected.This means that a frequency inverter drive can
endanger human life.
To prevent serious physical injury or considerable material damage, only
qualified persons familiar with electrical drive equipment may work on the
equipment. Only those persons who are familiar with mounting, installing,
putting into operation and operating inverters and have appropriate pro-
fessional qualifications shall be regarded as being qualified.These persons
must read the Instruction Manual carefully before installation and
commissioning and follow the safety instructions.
In this connection, the standards IEC 364 and CENELEC HD 384 or
DIN VDE 0100 and IEC Report 664 or VDE 0110 and national accident
prevention regulations or VBG 4 must be observed.
Repairs to the equipment may only be carried out by the manufacturer or
by a repair workshop approved by him. Unauthorised opening and
unprofessional intervention could lead to physical injury or material
damage.
A.2 Intended use
Inverters are components that are intended for installation into electrical
systems or machines.
When installed in machines, the inverter may not be commissioned (i.e. it
may not be put to its intended use) until such time as it is established that
the machine corresponds to the provisions of EC directive 89/392/EEC
(directive on machines); EN 60204 is to be observed.
In addition to the directive on low potential 73/23/EEC, the harmonised
standards of the series prEN 50178/DIN VDE 0160 in connection with EN
60439-1/DINVDE0660Part500andEN60146/DINVDE0558areapplied
with regard to inverters.
Thetechnicaldataandtheinformationconcerningconditionsofconnection
can be taken from the type plate and the documentation, and are to be
observed under all circumstances.

A-6
The inverter are to be protected against unauthorised stress.In particular,
components may not be bent and/or insulation distances changed during
transport and use.
Inverters contain electrostatically endangered components that can easily
be damaged when incorrectly handled. Electrical components may not be
mechanically damaged or destroyed.
When work is being carried out on live inverters, the applicable national
accident-prevention regulations (e.g. VBG 4) are to be observed.
Electrical installation is to be carried out in accordance with the relevant
regulations (e.g. lead cross section, fuses, earthed lead connection). Other
details are contained in the documentation.
Electronic devices are not totally fail-safe. The user himself shall be
responsible for securing the drive if the device breaks down.
If the inverter is used for special applications (e.g. explosion-proof
area), the required standards and regulations (e.g. EN 50014 and
EN 50018) must be observed.

A-7
More precise details can be found in the “Data booklet VF1000”.
Model codes when different to the standard
F 1 x x xV S ,,,,,
mit Kühlkörper, lang
Gehäuse, closed frame
mit integr. Funkentstörfilter
Sollwert analog,
RS232-Schnittstelle
,I5 ,G10 K2
VF1204S,
A.3 Model and accessories
General
The standard VF1000S model is denoted by the type designation only.
Versions other than the standard are denoted by the addition of model
codes to the type designation.
Each model code has a particular meaning – see inverter models. Model
codes are also used for inverters that are not in accordance with the list.
These are not given here.
Order or type designation:
For each deviant version, a configuration location is defined that can only
be assigned once. The number and sequence of codes to be added is
open; they must be separated from each other with commas.
Example:
Standard design: Analog reference input, 2 digital control inputs
• Varnished all-metal housing with plastic cover for
KEYPAD KP100 mounting, protection IP20
• Cold-plate design
• Live automatic circuit-breaker thermostat and
thermistor evaluation
• Operation Manual in German
F 1 x x xV
Effective continuous current
Mains voltage: 2 = 230 V
4 = 400 V
S range
S
S
MART
D
RIVE
VF1000 product line

A-8
A.4 Manufacturer´s declaration for frequency inverters
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere LTi Drives Gleichstromantrieb Handbücher
Beliebte Gleichstromantrieb Handbücher anderer Marken

Vincent Associates
Vincent Associates UNIBLITZ ED12DSS Bedienungsanleitung

EKSMA OPTICS
EKSMA OPTICS DQ-100-4 Stücklistenhandbuch

Chamberlain Garog
Chamberlain Garog D Series Bedienungsanleitung

Parker
Parker PDS Series Bedienungsanleitung

Festo
Festo DGC G Series Einrichtungshandbuch

Binks
Binks QS-5012-1-CE Bedienungsanleitung