MAKELSAN MRG33 Series Bedienungsanleitung

USER MANUAL
MRG/MST33 SERIES
STATIC VOLTAGE REGULATOR
200-300-400-500 KVA
AG-SD-117
Rev. No:0/Rev. Date:


USER MANUAL
MRG/MST33 SERIES
STATIC VOLTAGE REGULATOR
200-300-400-500 KVA

About the Manual
This Manual is prepared for the users of MRG/MST33 Series 200-300-400-500 KVA static
voltage regulator.
Companion Manuals
For more info about this device and its options, please visit www.makelsan.com.tr
Updates
Visit www.makelsan.com.tr for updates. Always use the latest manual.
Shipment
Carrying vehicles or handling accessories must have enough features and characteristics to carry
UPS’s weight.
DO NOT LIFT HEAVY DUTY WEIGHT WITHOUT HELP

CONTENTS
1 SAFETY AND WARNINGS............................................................................................................................................1
1.1 Warnings........................................................................................................................................................................1
1.2 Clearance and Access ................................................................................................................................................2
1.3 Storage ............................................................................................................................................................................2
1.4 Shipment ........................................................................................................................................................................2
2 PRODUCT DESCRIPTION.............................................................................................................................................3
2.1 General Information ..................................................................................................................................................6
2.2 Regulators Operation Modes .................................................................................................................................6
2.2.1 Normal Mode ............................................................................................................................................................6
2.2.2 Mechanical Bypass Mode.....................................................................................................................................6
2.3 User Panel......................................................................................................................................................................7
2.3.1 Opening Screen........................................................................................................................................................8
3 INSTALLATION................................................................................................................................................................9
3.1 Warnings ..................................................................................................................................................................9
3.2 Pre-installation check up.........................................................................................................................................9
3.3 Positioning.....................................................................................................................................................................9
3.4 Transportation Type of Cabinets ......................................................................................................................10
3.5 Mains and Load Connections ..............................................................................................................................10
3.5.1 External Protection................................................................................................................................10
3.5.2 Cabling and fuse configuration..........................................................................................................11
3.5.3 Cable connections...................................................................................................................................12
4 OPERATION ...................................................................................................................................................................14
4.1 Operation Procedure..............................................................................................................................................14
4.1.1 Circuit Breakers....................................................................................................................................................14
4.1.2 First start-up..........................................................................................................................................................14
4.1.3 Setting Mechanical Bypass...............................................................................................................................15
4.1.4 Performing a Complete Shutdown................................................................................................................16
4TABLE of TECHNICAL SPECIFICATIONS..................................................................................................17
6 GUARANTEE..................................................................................................................................................................19
6.1 Terms of Guarantee ................................................................................................................................................19
6.2 Cases Not Covered by the Guarantee...............................................................................................................20
7 CONTACT INFORMATION........................................................................................................................................22

MRG/MST33 Series STATIC VOLTAGE REGULATOR 200-300-400-500kVA
1
1 SAFETY AND WARNINGS
1.1 Warnings
This manual must be read before installing the MRG/MST33 series voltage regulator. The device
can be installed and started only by Makelsan authorized personnel.
Installation or start-up by unauthorized personal may cause damage to the device and serious
injury or death.
The regulator is designed to be used in continuous vertical fixed position applications.
THE REGULATOR MUST BE USED WITH GROUND CONNECTION.
Connect the ground cable before connecting the mains.
Ground currents may be as high as 30mA
THE INPUT BREAKER MUST BE SET OFF POSITION, THE VOLTAGE
REGULATORS MAIN/REGULATOR BREAKER MUST SET THE ‘’0’’ POSITION
BEFORE MAINTENANCE.
Service-Maintenance
All servicing and maintenance is done internally. All parts in the device can be serviced and
replaced only by a trained technician.
Preventative maintenance is recommended at least once a year from the
installation by authorized technical personnel. (This service will be
provided for a fee by our authorized MAKELSAN personnel.)
Fire extinguishing equipment must be kept nearby the regulator.

MRG/MST33 Series STATIC VOLTAGE REGULATOR 200-300-400-500kVA
2
1.2 Clearance and Access
Clearance
There must be spaces at least 1 meter for regulators fans around. Should not be permanent or
temporary use within the limits specified. Otherwise, the regulator performance will decrease.
Access
Operator reaches regulator via front, side and top panel on 200-300-400-500 kVA regulator,
enough area must be left for operator.
1.3 Storage
Regulator should be kept in a room or area where is protected from excessive moisture and heat
before commissioning. Regulator cabinets must be kept in the original packaging.
1.4 Shipment
Carrying vehicles must have be equipped properly and have features and characteristics
sufficient to carry regulator.
The regulator device shipment must be done on pallets.
Cabinet is equipped with four-wheel. In this way, it can be placed by moving easily. These wheels
are to be used on smooth surfaces only.
The front wheels of regulator must be locked after positioning properly. The rear side wheels
are fixed.
Move the regulator as rarely as possible.

MRG/MST33 Series STATIC VOLTAGE REGULATOR 200-300-400-500kVA
3
2 PRODUCT DESCRIPTION
Makelsan MRG/MST33 static voltage regulators are extensive input voltage ranged regulator
which controlled by microprocessor. MRG/MST33 are high efficiency and high speed static
voltage stabilizers.
General View

MRG/MST33 Series STATIC VOLTAGE REGULATOR 200-300-400-500kVA
4
Front View
1
Users Panel
2
Input Breaker
3
Evacuation Channel
4
Bypass/Regulator Breaker

MRG/MST33 Series STATIC VOLTAGE REGULATOR 200-300-400-500kVA
5
Rear View
1
Main Connectors Terminal
2
Load Connectors Terminal
Dieses Handbuch passt für folgende Modelle
9
Inhaltsverzeichnis