Mantracourt T24-RA Bedienungsanleitung

T24-RA
Potentiometer Acquisition Module
User Manual
mantracourt.com

Mantracourt Electronics Limited T24-RA User Manual
1
Introduction / Overview ........................................................................................................2
Connections .......................................................................................................................2
Power.............................................................................................................................2
Input Connections ..............................................................................................................2
Configuration......................................................................................................................3
Installation ......................................................................................................................3
T24 Toolkit....................................................................................................................3
T24-BSu Base Station .......................................................................................................3
T24 Toolkit ......................................................................................................................4
General Pages ................................................................................................................4
Setup Base Station Communications .....................................................................................4
Home ..........................................................................................................................5
Analyser .......................................................................................................................6
Data Provider Monitor ......................................................................................................7
Information ...................................................................................................................8
Battery and Radio Levels...................................................................................................9
Battery and Radio Levels Advanced Settings ......................................................................... 10
Data Rates and Quality ................................................................................................... 11
Input / Output Configuration............................................................................................ 13
Calibration By Certificate................................................................................................ 15
Calibration Advanced ..................................................................................................... 16
Channel and Encryption .................................................................................................. 18
Save and Restore .......................................................................................................... 19
Advanced Settings ......................................................................................................... 20
Installation....................................................................................................................... 21
Overview....................................................................................................................... 21
Power Supply / Battery ..................................................................................................... 22
Considerations When Selecting Batteries ............................................................................. 22
Battery Types .............................................................................................................. 23
Power Supply Modules .................................................................................................... 23
Lithium Ion /Polymer Module T24-BC1.............................................................................. 23
Physical Connections ................................................................................................ 24
Specification .......................................................................................................... 24
Suitable Batteries .................................................................................................... 24
Capacitor Module T24-BC2 ............................................................................................ 25
Mounting ....................................................................................................................... 26
Antenna ........................................................................................................................ 27
Internal Chip Antenna .................................................................................................... 27
External Antenna Option ................................................................................................. 27
External Antennas ......................................................................................................... 28
Antenna Orientation ...................................................................................................... 28
Specifications ................................................................................................................... 29
General Radio................................................................................................................. 29
T24-RA.......................................................................................................................... 29
Approvals ........................................................................................................................ 30
CE ............................................................................................................................... 30
FCC.............................................................................................................................. 30
Industry Canada .............................................................................................................. 31
OEM / Reseller Marking and Documentation Requirements .......................................................... 31
FCC.............................................................................................................................. 31
IC ................................................................................................................................ 31
CE ............................................................................................................................... 31
Declaration Of Conformity ................................................................................................... 33
Worldwide Regional Approvals .............................................................................................. 34
Important Note ............................................................................................................ 34
Warranty ......................................................................................................................... 34

Mantracourt Electronics Limited T24-RA User Manual
2
Introduction / Overview
The T24-RA is a remote acquisition module for the collection and processing of potentiometer resistance
measurements. The module measures the resistance and periodically transmits it. Between transmissions the
device is optionally in a power saving sleep mode to conserve batteries
Various devices are available that utilise the transmitted data and include handheld and PC displays etc.
Connections
This section will show you how to get the device pair working out of the box.
You will require a 3 Volt dc supply for the acquisition module which may be 2 X AA alkaline batteries.
Power
Attach power supply wiring to the module as shown below:
+ 3V Supply
0V Supply
Connect to a 3 Volt power supply or batteries.
WARNING: This module is not reverse polarity protected!
WARNING: The maximum voltage is 3.6V!
Input Connections
NOTE: The acquisition module may already be mounted in a connectivity module. In this case please refer
to the connectivity module user manual for the connection details.
+ 2V5
SHLD
GND
In +
Basic configuration with potentiometer shown below:
EXC +
SHLD
EXC -
N/C
In+
0%
100%

Mantracourt Electronics Limited T24-RA User Manual
3
Configuration
This section explains how to install software and configure the module. Please note that you will need the T24
Toolkit software and a T24-BS base station to allow your computer to communicate with T24 telemetry
devices.
Installation
T24 Toolkit
To configure the devices we must use the T24 Toolkit software application. This can be downloaded from our
web site or may be shipped with your products.
Install this on a PC or laptop.
Run setup.exe and follow the prompts to install the software.
T24-BSu Base Station
If you have a USB version of the base station (T24-BSu) then you just need to plug this into a USB socket on your
PC. If you are using an alternative base station then please refer to the appropriate manual.

Mantracourt Electronics Limited T24-RA User Manual
4
T24 Toolkit
The T24 Toolkit provides a means of simple configuration and calibration of the acquisition module along with
useful tools to aid integration.
Run the T24 Toolkit software application.
PLEASE NOTE: Depending on which acquisition module is selected the screenshots may vary slightly. This will generally be in naming of
units and device descriptions. The screenshots shown are those shown when a T24-PA strain gauge acquisition module is connected.
General Pages
Setup Base Station Communications
Select USB as the interface and select 1 as the Base Station Address.
In the toolkit all items that can be changed by the user are coloured orange.
To change a value just click on the relevant orange item. You will then be presented with a new dialog window
allowing you to change the value.
This may use a slider, text box or list to allow your new value to be entered.
Click the Home button to attempt communications with the base station.
If no communications can be established the toolkit will remain on this page. You will need to check that the
base station is powered and that it is connected to the converter correctly.

Mantracourt Electronics Limited T24-RA User Manual
5
Home
We now have successful communications with the base station so we can now pair with our device or we can
select the Spectrum Analyser mode or Data Provider Monitor mode.
To connect to our device we will pair. This is achieved by power cycling the device. Pairing removes the need
to know the radio settings of the device you are connecting to and also ensures that it is in a suitable state for
configuration.
Pairing Procedure
Remove power from the acquisition module
Click the Pair button on the toolkit.
You now have 10 seconds to re-apply power to the acquisition module.
If you connect successfully the toolkit will change to the Information page.
If the pairing fails try again.
NOTE: Pairing with the toolkit will not change the radio configuration settings of the connected device.

Mantracourt Electronics Limited T24-RA User Manual
6
Analyser
The analyser page is provided as a tool and will not normally be needed unless you plan to change channels and
want to find the best channel to select, or to diagnose poor communications issues.
This page shows the radio signal levels detected across all the channels available to the T24 series of devices.
Using this tool may help in detecting noisy areas and allow you to decide on which channels you may want to
use.
The above charts show the traffic from a Wi-Fi network and it can be seen to be operating over channels 6 to 9
and it would be best (though not essential) to avoid using these channels.

Mantracourt Electronics Limited T24-RA User Manual
7
Data Provider Monitor
T24 acquisition devices normally operate in low power mode and periodically transmit Data Provider
packets
This page shows all detected Data Provider packets which may be useful for checking that a device is
operational.
NOTE: When the toolkit connects to a device to enable configuration it will usually inhibit the transmission of Data Provider packets.
The Start Logging button will ask for a filename and proceed to log the received data to a CSV file in the
following format:
Data Tag, Elasped mS, Value
The View Last Log button will launch the application associated with CSV files and open the last logged file.

Mantracourt Electronics Limited T24-RA User Manual
8
Information
Once successfully paired to a device this page is displayed.
This page shows you information about the connected device.
Items you can change:
Name
You can enter a short description which may help you recognise this device in the future.

Mantracourt Electronics Limited T24-RA User Manual
9
Battery and Radio Levels
Here you can see the voltage of the battery and the radio signal levels at the base station and the remote
acquisition module. This simple view gives an LQI value which stands for Link Quality Indicator. This value will
range from 0 to 100 and within this band you should still achieve communications. As the level drops towards
zero communications may become intermittent but still achievable.
You can set the level at which the acquisition module reports a low battery.
If the battery voltage is below the Low Battery Level the bar will be coloured orange.
Items you can change:
Low Battery Level
Click this item to set the battery low level.
Clicking the Advanced button will give more detailed information on the RSSI and CV levels of the received
radio packets.
Inhaltsverzeichnis
Andere Mantracourt Steuereinheit Handbücher
Beliebte Steuereinheit Handbücher anderer Marken

Festo
Festo Compact Performance CP-FB6-E Stücklistenhandbuch

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Bedienungsanleitung

JS Automation
JS Automation MPC3034A Bedienungsanleitung

JAUDT
JAUDT SW GII 6406 Series Kurzanleitung

Spektrum
Spektrum Air Module System Bedienungsanleitung

BOC Edwards
BOC Edwards Q Series Bedienungsanleitung