INSTALLATION INSTRUCTIONS
____________________________________________________________________________
WARNING:
DO NOT UNDER ANY CIRCUMSTANCE
CONNECT THE EXHAUST DRAIN LINE
DIRECTLY TO A SEWER LINE.
NOTES: If equipment is installed where elevation ex-
ceeds 2,000 feet (609.6 meters) above sea level, specify
installation altitude so that proper gas orices can be pro-
vided.
The only available space to supply utilities to the gas boiler
is the 6” (152mm) space between the oor and the cabi-
net. Allow 3” (76mm) space from side wall and 6” (152mm)
from real wall if adjoining walls are combustible.
CAUTION: Before connecting water to this unit, water
supply should be analyzed to make sure hardness is no
greater than 2.0 grains and pH level is within the range of
7.0-8.5. Water which fails to meet these standards should
be treated by installation of water conditioner. EQUIP-
MENT FAILURE CAUSED BY INADEQUATE WATER
QUALITY IS NOT COVERED UNDER WARRANTY.
DRAIN LINE INSTALLATION: The drain port of the unit
is marked with a colored tag and is located at the lower
rear left side of the boiler as viewed from the front. This
exhaust line may be left open if the boiler has to be situ-
ated in a tiled oor depression or a tiled curb section that
is equipped with drain facilities. If this is not the case,
then a 2” (51mm) NPT. drain line must be connected
to divert the exhaust to the oor drain. If it is necessary
to use more than three elbows, increase the size of the
waste line accordingly.
NOTE: PVC & CPVC PIPE ARE NOT
ACCEPTABLE MATERIALS FOR DRAINS.
SERVICE CONNECTIONS
Electrically Operated
EP Power Supply - Use wire suitable for at least 90°C. Nominal amp per line wire:
Volts 24 kW 32 kW 36 kW 42 kW 48 kW
3 pH 3 pH 3 pH 3 pH 3 pH
208 (197-219)
240 (220-240)
480 (360-500)
66
60
32
89
77
39
100
91
47
117
-
-
-
116
58
Details of other electrical systems available upon request.
CW1 Cold Water - 3/8” (10mm) NPT for cold water to boiler. Cold water lines will have a
maximum of 50 PSI (3.5kg/cw2) and a minimum of 25 PSI (1.8 kg/cw2) water pres-
sure.
CW2 Cold Water - 3/8” (10mm) NPT for cold water to condenser. Cold water lines will have
a maximum of 50 PSI (3.5kg/cw2) and a minimum of 25 PSI (1.8 kg/cw2) water pres-
sure.
DDrain - Pipe full 2” (50mm) I.P.S. to ush oor drain capable of receiving water owing
at a maximum rate of 5 gallons (19 liters) per minute. DO NOT MAKE SOLID CON-
NECTION TO FLOOR DRAIN.
ST Steam Take-off - Connection for operation of adjacent steam powered equipment.