INSTALLATION & OPERATION MANUAL 10280 REV 3 (11/22) PAGE 5 OF 28
I
I
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
Immediately after unpacking, check for possible shipping damage. If the tilting braising pan is found to be
damaged, save the packaging material and contact the carrier within 15 days of delivery.
Before installing, verify that the electrical service agrees with the specifications on the rating plate located
on the left side panel as you face the front of the braising pan. If the supply and equipment requirements do
Information on the construction and installation of ventilating hoods may be obtained from the standard for “Vapor
1. Uncrate carefully. Report any hidden freight damage to the freight company immediately.
2. The pressure relief valve is located at the right rear of the unit. This area should be kept clear and should not be
must vent to the atmosphere.
4. To level the unit use a spirit level in all directions on the top of the kettle (lid up). Adjust the bottom foot on each leg to
10. Appliance location must allow air supply to unit and obstruction free clearance for air opening into the combustion
chamber.
11. Make service connections as indicated.
12. Check the pressure gauge on the front panel before operating. If the pressure gauge does not indicate green vacuum
The serial plate on the lower right side of the unit indicates the type of gas your unit is equipped to burn. Do NOT connect
to any other gas type.
side of the combination valve for checking pressure.
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas required for
appreciable drop. Fluctuations of more than 25% on natural gas, and 10% on propane gas, will create pilot problems and