Matsuko Switch Box Bedienungsanleitung

1
SWITCH BOX • SWITCH BOX TIMER
SWITCH BOX TIMER + PUMPGUARDTM
INSTALLATION AND
OPERATING MANUAL
WARNING:
Ensure that your Matsuko Switch Box is switched off at the
mains before you attempt to conduct any type of maintenance.

2
WARNING:
PLEASE READ THE FOLLOWING SAFETY INFORMATION FIRST.
IMPORTANT SAFETY
INFORMATION
PLEASE READ CAREFULLY
• Always consult with a qualified electrician
before attempting any electrical
installation.
• Always isolate the unit from mains
electricity supply before carrying out any
maintenance.
• Use in the area of the garden pond only if
the installation complies with the relevant
wiring regulations.
• Power must be supplied through a Residual
Current Device (RCD) with a residual
operating current not exceeding 30mA.
• This unit must be earthed.
• Never use a fuse larger than 13 amps on
the power lead.
• The unit must not be submerged in water.
• Young children should always be
supervised near water.
IN THE EVENT OF A
POWER FAILURE
Following a power failure, the
Switch Box will restart with each line in
the same position as before the power
interruption. The Switch Box Timer will
resume as per its programming. However, in
order for all of this to occur, the Switch Box
must be run for a minimum of 48 hours with
uninterrupted power to enable the back up
capacitor to be fully charged. This function
is for short term power cuts only. Long
term power outages will result in all models
needing to be re-programmed.
PRODUCT INFORMATION
• Model Ratings: 220-240V. 5 LINES. 1500
W MAX POWER PER LINE.
3000 W MAX TOTAL OUTPUT
• All units are IP56. All units are
CE approved.
Disposal Of Your Old Product
Your product is designed and manufactured with high quality material and
components, which can be recycled and reused. When this crossed-out wheeled
bin symbol is attached to a product, it means the product is covered by the
European Directive 2002/96/EC. Please contact your local authority about
correct disposal for electrical and electronic equipment.
Please act according to your local rules and do not dispose of your old products with your
normal household waste. The correct disposal of your old product will help prevent potential
negative consequences for the environment and human health.

3
CONTENTS
Introduction 4
Dimensions & Specifications 6
Installation 7-10
Programming (Switch Box Timer, Switch Box Timer + PG) 11-14

4
INTRODUCING THE MATSUKO SWITCH BOX RANGE
Congratulations on purchasing your Matsuko Switch Box. All Matsuko Switch Boxes are
built to complement your outdoor enjoyment, giving you total control of your lifestyle. All
Matsuko Switch Boxes are designed to be weatherproof, stylish, robust and safe in your
outdoor environment.
The Matsuko Switch Box range comprises of 3 models:
SWITCH BOX*
5 Way Switch Box - Offering up to 5
lines of power up to 1500 W per line.
Each connected device can be
manually powered on or off at the
touch of a button.
*NOTE:- total unit output is limited
to 3000W.

5
SWITCH BOX TIMER*
5 Way Programmable Switch Box -
Offers 5 lines of power each delivering
up to 1500 W per line.
Every device that gets connected can
be individually programmed to power
on or off at your convenience.
*NOTE:- total unit output is limited
to 3000W.
SWITCH BOX TIMER +
PUMPGUARDTM*
Gives you the same great flexibility over
your devices as the Timer version but
with the added benefit of PumpGuardTM
and power consumption monitor.
The PumpGuardTM will protect your
primary pump in case of failure and also
show you the power consumption of line
1 individually plus lines 1 - 5 combined.
*NOTE:- total unit output is limited
to 3000W.

6
226 mm
160 mm
70 mm
* 1500 Watts per line when installed into the mains household electrical wiring using appropriate cable.
** A double layer capacitor stores electrical energy to remember your programs in case of a power cut for at least 24
hrs when fully charged. The Matsuko double layer capacitors need minimum 48 hours to be fully charged.
DIMENSIONS
Switch
Box
Switch Box
Timer
Switch Box
Timer + PG
Output 220/240 V 220/240 V 220/240 V
Max. Power Per Line* 1500 W 1500 W 1500 W
Max. Total Output 3000 W 3000 W 3000 W
Programmable –
Number of Lines 5 Lines 5 Lines 5 Lines
Model Number Switch Box Switch Box Timer Switch Box Timer + PG
Internal Fuses 6.3A G-Fuse 5 mm x 20 mm
Double Layer Capacitor** –
PumpGuardTM + Power consumption ––

7
INSTALLATION (PLEASE SEE SEPARATE SHEET FOR WALL MOUNT INSTRUCTIONS)
OPENING THE COVER
To open the cover insert a small
screwdriver (1) or similar implement into the
round opening at the base of the cover.
Use it to push the fastening connection
towards the left until the catch is released
(2). Gently lift the cover open to the
maximum angle of 100 degrees (3). DO NOT
force the cover to open further.
Once you have connected all your appliances
(see page 8), always secure the lid with the
closing screw (the closing screw is packed
together with the 2 blanking plugs).
Locking Screw
1
2
3
max. 100o!
WARNING: ALWAYS TURN THE SWITCH BOX POWER
OFF AT THE MAINS ELECTRIC BEFORE OPENING
THE COVER. ALWAYS SECURE WITH CLOSING SCREW.

8
IMPORTANT: Connect the wires to the appropriate pins (Live,
Neutral, Earth). Up to five outgoing connections can be installed
into the Switch Box (4-8).
Power input is supplied into a separate mains channel (9). Use two
screws to secure the cable grip and fix each cable into place inside
the Switch Box (11). Outside the Switch Box, if using the supplied
cable gland sealing ring, ensure the cable gland sealing ring is
turned clockwise until the cable is firmly secured and sealed in the
connector (10).
CONNECTING THE CABLES
WARNING: ALWAYS TURN THE SWITCH BOX POWER
OFF AT THE MAINS ELECTRIC BEFORE OPENING
THE COVER. ALWAYS SECURE WITH CLOSING SCREW.
It is essential for your safety that you ensure the power of all inputs (including mains) is turned
off before proceeding with installation. Do not attempt to install cables without required
knowledge and expertise! Use of a qualified electrician is recommended for all installations.
Use a screw
driver to push
the fastening
clip over on
the terminal
block, place
the cable into
the terminal
block and
release the
clip securing
the cable.
Always
use ferrule
clamps on
the cables to
ensure a safe
connection.
Our NEW PCB terminal blocks are
easy click push connectors allowing
the user to connect the power in
and out cables.

9
Once you have connected all of your appliances, always secure the lid with the closing screw.
There are two blanking plugs supplied with Matsuko Switch Boxes. These blanking plugs
should be used to replace the cable glands if you decide not to wire a device in at any point.
FINISHING CONNECTIONS & BLANKING PLUGS
WARNING: ALWAYS TURN THE SWITCH BOX POWER
OFF AT THE MAINS ELECTRIC BEFORE OPENING
THE COVER. ALWAYS SECURE WITH CLOSING SCREW.

10
To activate each appliance, simply press the corresponding on / off button on the front of
the Switch Box, labelled:
For more detailed programming instructions (for the Switch Box Timer) see page 11.
TYPICAL EXAMPLE OF A COMPLETE INSTALLATION
PUMP LIGHTS FEEDER SKIMMERPOWER
IN
UV
PUMP LIGHTS FEEDER SKIMMERPOWER
IN
UV
ACTIVATING CONNECTED APPLIANCES (SWITCH BOX ONLY)
Andere Handbücher für Switch Box
2
Dieses Handbuch passt für folgende Modelle
2