Maxinventer 30S Bedienungsanleitung

Installation & Operation Manual
Full Inverter Pool Heat Pump
Maxinverter-30S
Thank you very much for purchasing our product,please keep and read this manual carefully before
you install heat pump.


1
Dear Customer
We really appreciate that you have chosen our swimming pool
heat pump.
Meticulously designed, using only the highest quality materials
and components, your pool heat pump is designed to last longer.
To enable your swimming heat pump to give you many years
of perfect trouble-free service, we would recommend you to
follow the instructions of the service manual carefully.

2
-IMPORT SAFETY PRECAUTIONS
IMPORTANT NOTICE:
This guide provides installation and operation instructions for the pool heat pump. Please consult the
technical for any questions regarding this equipment.
ATTENTION INSTALLER:
This guide contains important information about the installation, operation and safe use of this product. This
Information should be given to the owner and operator of this equipment after installation.
ATTENTION USER:
This manual contains important information that will help you in operating and maintaining this heat pump.
Please retain it for further reference.
WARNING- Before installing this product, read and follow all warning notices and instructions which
are included. Failure to follow safety warnings and instructions can result in severe injury, death, or property
damage.
---- RISK OF ELECTRIC SHOCK OR ELECTROCUTION.
The electrical supply to this product must be installed by a licensed or certified electrician in accordance with
national electrical standard. Improper installation will create an electrical hazard which could result in death
or serious injury to heat pump uses, installers or others due to electrical shock, and may also cause damage
to property. Read and follow the specific instructions inside this guides.
WARNING- This pool heat pump is not intended to operated or adjusted by young children, elderly,
infirm or physically/mentally handicapped persons, violating the warning will be annulled warranty of the
product.
DANGER

3
Fluorinated greenhouse gas –(R32)
The device contains the fluorinated greenhouse gas (R32) which is required for the device to work.
Industrial designation HFC-32
Common designation R32
Global warming potential (GWP) 675
Further information can be found on the device itself or the Specifications.
WARNING!
Risk of fire and explosion through leaking finned heat exchanger!
The refrigerant circuit of the finned heat exchanger contains highly pressurised, easily flammable,
odourless gas. Risk of fire and explosion in the event of uncontrolled gas leakage.
- Action of filling gas must be conducted by professional with R32 operating license.
- Keep the heat pump away from heat sources and naked flames.
- Do not drill into or scorch the heat pump.
- Do not use any objects apart from those permitted by the manufacturer to speed up the defrosting
process.
- Immediately shut off the heat pump if you suspect a gas leakage.
- The refrigerant is odourless. Always keep ignition sources away from the installation site of the heat
pump.
- Contact an authorized expert if you suspect a gas leakage.
WARNING!
Risk of electric shock!
A faulty electrical installation or a mains voltage that is too high can lead to electric shock.
- Have the installation, initial start-up and maintenance of the heat pump carried out by authorized
technician only.
- Please always cut the power supply if you want to open the cabinet to reach inside the heat pump
as there is high voltage electricity inside.
- Only start work on the heat pump after checking all safety regulations.
- Only connect the heat pump if the mains voltage from the power socket matches the voltage
indicated on the rating plate.
- Do not operate the heat pump if there is visible damage or the mains cable or the mains plug is
defective.

4
- Do not open the housing. Leave repairs to qualified specialists. Liability and warranty claims are
excluded in the event of repairs carried out on your own, improper operation.
- Ensure that children do not insert any objects into the fan blade and heat pump.
- Ensure that the electrical system to which the heat pump is connected has an earth conductor.
- If the unit would be installed where is vulnerable to lightning stroke, lightning protection
measurements must be carried out.
ATTENTION!
- The manufacturer declines any responsibility for the damage caused with the people,objects and of
the errors due to the installation that disobey the manual guideline. Any use that is without
conformity at the origin of its manufacturing will be regarded as dangerous.
- Please always keep the heat pump in the ventilation place and away from anything which could
cause fire.
- Don’t weld the pipe if there is refrigerant inside machine. Please keep the machine out of the
confined space when make gas filling by the authorized technician.
- Please always empty the water in heat pump during winter time or when the ambient temperature
drops below 0℃, or else the Titanium exchanger will be damaged because of being frozen, in such
case, it will be out of warranty for this machine.
- Please well keep the display controller in a dry area to protect the display controller from being
damaged by humidity.
* INDEX
1. Accessories description
2. Attention for safety
3. Installation of the unit
4. Specifications
5. Electrical Wiring
6. Instruction of operation
7. Adjusting and Initial operation
8. Operation and maintenance
9. Error codes & Solutions
10. WiFi-Function

5
Each unit produced by our factory is with the following accessories:
For function you need to purchase at least the following parts for each unit:
NOTE
The types and quantity of the water pipes, valves, filter equipment, sterilizing equipment which used for
the swimming pool heating/circulation pipe system, depend on the project design.
We suggest not to install auxiliary electric heaters in the system. If must install auxiliary electric heaters,
it should be operated by the specialized persons, and our company has no responsibility for all the
problem cause by the auxiliary electric heater.
Illustrations of machine
No.
Name
Qty.
Use
1
Instruction Manual
1 PC
Guide users to install the system
2
Drain-pipe
1 PC
Used for draining the condensate water
3
Drain-pipe connector
1 PC
Connect the drain pipe to the heat pump unit
4
Rubber shock absorber
4 PCS
Reduce vibration and reduce noise
5
Heat pump unit
1 SET
For heating water
6
Water connection
2 SET
Connect the piping system
No.
Name
Qty.
use
1
Water pump
1
Cycle the heated water
2
Filter system
1
Protect the heat pump from pool water
3
Water pipes system
1
Connect the equipment and make circulation
1. Accessories description

6
●Confirm the ground connection, if the ground connection is not correctly done, it may cause
electric shock. And please cut off the power in the lightning storm weather.
●If install the heat pump in a small room, it must keep good ventilation.
●The main power switch should be out of the reach of Children.
●Don't put finger or stick into the air inlet or air outlet as the high-speed rotor may cause injury.
●When an exception happened (burning smell etc..), turn off the manual power switch immediately
and contact with after-sale service department.
●When the unit needs to be removed or re-installed or repaired, please entrust after-sale service
department and specialized personnel to do it. If the installation/ maintenance is not well done, it
may cause unit operation failure, electric shock, fire, hurt, leaking, etc.
●Must not be unauthorized reformed, otherwise it may cause electric shock or fire.
● Must not install the unit with combustible around.
●Confirm the installation base is strong enough to avoid falling of the heat pump.
● Confirm leakage protection switch is installed to avoid electric shock or other issues.
2. Attention for safety
Range of application:
1.Power supply: 220~240V/1N~50/60Hz; 380~415V/3N~50/60Hz.
2.Environment temperature: -15°C〜43°C
3.Water temperature range: 8°C~40°C in Heating function
8°C~28°C in Cooling function

7
● When cleaning the unit, the operation should be stopped, and power switch should be turned off.
3.1 Installation Illustration
Above illustration is just for the reference, please take the advice of authorized installers.
3.2 Advised installation space
Keep the following indicated space for operation and maintenance when make the installation.
3. Installation of the unit

8
3.3 Additional By-pass kits
The additional By-pass kits is suggested to be put into the piping system to get the better adjustment
of water flow.
3.4 Heat pump unit size (mm)
A
B
C
D
E
F
G
H
I
J
K
Maxinverter-13S/17S/21S
641
896
389
363
128
640
128
107
340
26
11
Maxinverter-30S
741
1056
428
401
173
710
173
102
440
27
11
Inhaltsverzeichnis
Beliebte Wärmepumpe Handbücher anderer Marken

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Bedienungsanleitung

Dimplex
Dimplex LI 16I-TUR Benutzerhandbuch

Carrier
Carrier WSHP Open v3 Kurzanleitung zur Einrichtung

TGM
TGM CTV14CN018A Bedienungsanleitung

Carrier
Carrier 38MGQ Series Bedienungsanleitung

Kokido
Kokido K2O K880BX/EU Fehlerbehebungshandbuch