2
1.4 Main Specification
105 ~ 115% rated output power
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Peak) Note 10
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
DIMENSION
OTHERS
NOTE
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
90 ~ 264VAC 127 ~ 370VDC
Cold start 80A/230VAC 40A/115VAC
2mA / 240VAC
-30 ~ +70℃(Refer to “Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH non-condensing
±0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
192.1K hrs min. 63.9Khrs MIL-HDBK-217F (25℃)
PF 0.95/230VAC at full load PF 0.95/115VAC at 60% load≥ ≥
℃
.
℃ ℃
※ : , https://www.meanwell.com/serviceDisclaimer.aspx
ENVIRONMENT
PROTECTION
380*141.4*60mm (L*W*H)
Protection type :Shut down O/P voltage,re-power on to recover
Protection type :Shut down O/P voltage, recovers automatically after temperature goes down
Adjustment of output voltage is allowable to 50~120% of nominal output voltage.
Please refer to the function manual
20A/230VAC 21A/115VAC
4.5Kg;4pcs/19Kg/2.46CUFT
47 ~ 63Hz
Protection type : unit will shut down after 5 sec, re-power on to recover.Constant current limiting,
FUNCTION
REMOTE ON/OFF CONTROL
AUXILIARY POWER
DC-OK SIGNAL
Power ON : Short circuit Power OFF : Open circuit
12V@0.5A tolerance±10%, ripple 150mVp-p
The TTL signal out, PSU turn on = -0.5 ~ 0.5V ; PSU turn off = 3.5 ~ 5.5V. Please refer to the Function Manual.
SAFETY STANDARDS
SAFETY &
EMC
(Note.7,8)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:6KVDC I/P-FG:4KVDC O/P-FG:4KVDC
I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
UL62368-1,TUV BS EN/EN62368-1, approved ; design refers to BS EN/EN61558-1, BS EN/EN60335-1EAC TP TC 004
MTBF
PACKING
Adjustment of constant current level is allowable to 20 ~ 100% of rated current.
Please refer to the Function Manual.
OUTPUT VOLTAGE
PROGRAMMABLE(PV) Note 5,6
OUTPUT CURRENT
PROGRAMMABLE(PC) Note 6
95% 95.5% 96%
168 ~ 200V 273 ~ 320V 413 ~ 460V
EMC IMMUNITY
EMC EMISSION
Parameter
Parameter
ESD
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
Conducted
Radiated
Harmonic Current
Voltage Flicker
Standard
Standard
EN55032 (CISPR32)
EN55032 (CISPR32)
EN61000-3-12
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-6-2
EN61000-4-6
EN61000-4-8
EN61000-4-11
Test Level / Note
Test Level / Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 3
Level 3
2KV/Line-Line 4KV/Line-Earth
Level 3
Level 4
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Class B
Class A
-----
-----
OVER VOLTAGE CATEGORY Ⅲ; According to EN61558 ; altitude up to 2000 meters.
VOLTAGE ADJ. RANGE
MODEL
DC VOLTAGE (Factory default)
RATED CURRENT(Max.)
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
2000ms, 60ms/230VAC at full load 2500ms, 60ms/115VAC at 60% load
16ms/230VAC at 75% load 10ms/230VAC at full load 10ms/115VAC at 60% load
RIPPLE & NOISE (Max.) Note.2
VOLTAGE TOLERANCE Note.3
RATED POWER(Max.) Note.11
1.15Vp-p 2.3Vp-p 3.8Vp-p
±0.5% ±0.5% ±0.5%
±0.5% ±0.5% ±0.5%
±1.0% ±1.0% ±1.0%
PHP-3500-115 PHP-3500-230 PHP-3500-380
3500W 3500W 3500W
115V 230V 380V
26.3A 16.1A 10.5A
110~160V 170~260V 260~400V
By built-in potentiometer, SVR
CURRENT (Factory default)
POWER (Factory default) 2898W
25.2A
SHORT CIRCUIT Protection type : Constant current limiting, unit will shut down after 5 sec, re-power on to recover.
15.2A
3500W
9.2A
3500W