MedSpace DFU-0133 Bedienungsanleitung

DISPLAY FRAME UNITTM USER MANUAL
EN
subject to modication, errors and omissions excepted * 11-2014 * V1

2we organise your space

2we organise your space
3
we organise your space
DISPLAY FRAME UNITTM
SUMMARY
GENERAL INFORMATION 04
INSTALLATION IN WET ROOMS 12
PRODUCT INFORMATION 13
GETTING STARTED 15
TROUBLESHOOTING 26
TECHNICAL SPECIFICATION 27
WARRANTY TERMS 36

4we organise your space
GENERAL INFORMATION - SAFETY
CAUTION
• Only qualied specialist staff may carry out service tasks. Service work is necessary, if the unit has been dam-
aged, e.g. if the mains plug or mains cable have been damaged, if liquid or items are present inside the device, if
it has been exposed to water or moisture, if it does not work properly or if it has fallen down.
• Never remove the casing covers or modify the product in any way. This can cause an electric shock or burn you.
• Immediately pull the plug, if you notice that your product emits smoke, smells burnt or emits unusual noises and
ask your specialist dealer for advice.
• Do not allow the product to come into contact with liquids. Liquid in the casing can cause a re, electric shock or
damage the device. Immediately pull the mains plug out, if an item or liquid gets into the casing. Notice that the
apparatus shall not be exposed to splashing or dripping liquids and no objects lled with liquids, such as vases,
shall be placed on the apparatus.
• Keep small items away from the product. These can fall into the casing and cause a re, an electric shock or
damage the device. Don‘t try to reach into the housing or plugs with wires or the like.
• Never touch not-isolated parts of the plug, if the device is connected to the power adapter!
• Where the mains plug or an appliance coupler is used as the disconnect device, the disconnect device shall
remain readily operable.
• Avoid any impact and do not allow the product to fall!

4we organise your space
5
we organise your space
DISPLAY FRAME UNITTM
GENERAL INFORMATION - CLEANING
Do not clean the screen surface with a coarse item or tissues! These can damage the display surface. A clean, dry
cloth is sufcient; never use aggressive cleaners or solvent such as alcohol, thinner or cleaning petrol to clean the
Display Frame UnitTM. These agents may cause damages and corrode the casing. Do not wipe the screen forcefully.
CAUTION
Never apply strong pressure to the screen of the Display Frame UnitTM , because it could otherwise be damaged or break.
Never touch the screen with pointed or sharp items, such as pencils, ballpoint pens, knives, scalpels, screwdrivers etc.
Wear protective gloves when handling a damaged display. Possibly leaking liquid crystal is poisonous and may under no
circumstances come into contact with eyes or mouth.
The screen of the monitor is coated with layers of thin lms to prevent unwanted reections. Damages to these layers can
lead to irreversible changes in appearance such as uneven color, discoloration and/or scratches. So please do not paste,
stick or write anything on the screen and avoid condensation.

6we organise your space
GENERAL INFORMATION - MOUNTING
Your product can either be installed on-wall or in-wall. MedSpace offers multiple mounting systems for almost every
application and is sure to have also the appropriate solution for your installation on hand. Please ask your authorized
MedSpace partner for assistance in this regard.
IMPORTANT
Please make sure to have the latest rmware installed before mounting the unit. For details please visit the Support &
Service section of our website.
NOTE
In order to have access to the USB port after installation we recommend installing a USB extension cable.
CAUTION
MedSpace does not offer any guarantee for the screws and dowels delivered with the product. These may need to
be replaced on site when considering the weight and quality of the load-bearing wall, since MedSpace is not familiar
with the construction environment. Electrical installations are to be performed by a skilled technician, while observing
the regulations of the standard VDE100 part 701. MedSpace will not be held liable for improper installation!
NOTE
To ensure proper operation only use the supplied cables. Using other cables and lengths may cause disturbances to the
image quality or even the functionality.

6we organise your space
7
we organise your space
DISPLAY FRAME UNITTM
GENERAL INFORMATION - INSTALLATION
Operation and Storage Requirements
The ambient temperature for operating the device is between +5 and +50 degrees Celsius. Do not install the device
in the proximity of heat sources, such as heating pipes, heaters, furnaces or other devices, which radiate heat. It is not
necessary to provide air circulation to dissipate the heat. Mount the device in such a way that it is protected against
moisture. Trouble free operation is ensured up to 75% air humidity.To prevent fire or electric shock, never allow
liquids to enter the unit. The product must be stored in dry and well-ventilated rooms, without extreme temperature
fluctuations. Heat sources and aggressive active substances may not be stored in the proximity of the device. The
required storage temperature is 0°C - +60°C at an air humidity of 5 - 85% RH. The device must be stored in the
complete packaging, as delivered.
Installation
Have this product installed by qualified staff only. Use the mounting systems which are specified or recommended by
MedSpace. Install the product in a way that it is xed properly and take care that children are not exposed to danger.
Please take extra care during installation, avoid impacts. Before cabling your monitor system, check that the power is off.
To avoid any possibility of electric shock, always connect your equipment to properly earthed outlets. Use of power cords
or adapters other than those provided may cause re or malfunction. Place this product as close to the power socket as
possible. Leave enough space to insert and remove the power plug on demand. Even if you switch off the product with
your remote control, power is not cut off unless the power cord is unplugged.
Installation Environment
Avoid direct light or sun exposure, direct proximity to heat sources, outdoor installation. The product is specifically
designed for indoor use only. There is the danger of fire and of electric shocks and damage to the device, if it is
operated outdoors. Do not place any heat sources such as radiators and heat registers, etc. near the monitor. To
reduce eye strain, avoid installing the monitor system against a bright background such as a window. Position the monitor
system at the height of your eye level and directly in front of you at a comfortable viewing distance.

8we organise your space
Installation of Power Adapters
The device may only be operated with the provided power adapter. The rated voltage is indicated on the product
label. The device is factory-set to the optimal operating voltage (see Technical Specication). Use only power cords
and plugs that are suitable for your local electrical outlets. Install the power cords in such a way that it does not
obstruct anyone. Ensure furthermore that the cable is not clamped and that it cannot be pulled out accidentally from
the power adapter. Do not install the power cords in the proximity of heating elements and never place heavy items
on the cable or power adapter. Do not modify or arbitrary repair the power cords.
CAUTION
Do not use any power cords or adapters other than those provided with this product! Use of power cords or
adapters other than those provided with this product may cause re, electric shock or malfunction. If several kinds of
power cords are provided with this product, use the one that ts your power socket. Do not let the adapter hang down
while using. Do not cover or wrap the adapter. Leave space around the adapter to prevent overheating. The individual
components can be destroyed, if the polarity is reversed or an incorrect connection is used.
A goodwill replacement is not possible in such cases, since each device is submitted to meticulous quality
inspections prior to shipping. The connecting plugs must be attached in such a way that the connector is held rmly.
Have trained technical personnel install the electrical facilities necessary for mounting. The power adapter has to be
installed in ventilated areas due to the heat emission! Connect the power cord to a grounding outlet! Never cut or
damage the power cord!
Please disconnect the device from the power adapter in the following cases:
• The device is out of use for a lengthy period.
• The device malfunctions or displays other unusual features, necessitating maintenance work.
• During a thunderstorm.
Please plan the positioning of the power adapter and the source cables before proceeding with the structural
measures and positioning of the monitor system. Observe the protection zones when placing the power adapter!
For in-wall applications please bear in mind that the power adapter has to be placed beyond the inset due to heat
emission!

9
we organise your space
DISPLAY FRAME UNITTM
NOTE
The power adapter should be adequately secured to prevent it from becoming unstable and/or falling. Make sure the
power source circuits are properly grounded. Use the supplied power cord in order to connect it to the power source. If your
installation requires a different power cord, be sure to use an ofcially approved power cord displaying the mark of the
safety agency that denes the regulations for power cords in your country. Please consider that the AC outlet for the power
adapter is placed within reach of the monitor system and should be easily accessible in case it needs to be powered off.
Do install the product in a dry environment where the operating ambient temperature might not exceed 40°C / 104°F.
Also don´t position the power adapter on top or on the back of the monitor system in order to prevent thermal
overload.
Ensure that your installation complies with your national safety rules. Any servicing, adjustment,
maintenance or repair must be performed only by service-trained personnel.
Ensure that the power adapter is installed in a serviceable location, to access it easily in case of a defect. If you choose to
place the power adapter in a separate space, take care that the ventilation is present, because the power adapters need
convection cooling for stable working conditions.
When placing the power adapter in a fully enclosed space, make sure the air ow around the sides and top of the power
adapter is not restricted. According to a common rule of thumb the minimum dimensions for a niche for the power adapter
may be dened as follows: please calculate the length of the power adapter plus an additional gap of at least 100mm all
around for DC 12V power adapters and 200mm all around for DC 24V power adapters.

10 we organise your space
GENERAL INFORMATION - TRADEMARK
HDMITM
HDMI, HDMI CEC (HDMI Consumer Electronics Control), the HDMI logo and HIGH-DEFINITION MULTIMEDIA
INTERFACE are trademarks of HDMI Licensing LLC.
ENERGY STAR
This product has earned the ENERGY STAR for meeting U.S. Federal energy efficiency guidelines as set by the
department of energy and environmental protection agency. The ENERGY STAR program exists to provide energy
saving guidelines and help promote energy efficient products and practices. On delivery condition the Display Frame
UnitTM qualifies for ENERGY STAR. Please notice that changes to certain features, settings and functions of this
product can change its power consumption.
EFFICIENCY LEVEL
Only products that meet specic criteria for active mode, no-load mode, and power factor may qualify as efciency
LEVEL V.
V
Dieses Handbuch passt für folgende Modelle
7
Inhaltsverzeichnis

















