Warning: be sure to wait for the correct termination of the record, otherwise
later when reading incorrect information in the work of the outdoor panel there may
be failures.
Chapter №22 Reading the electronic media DS1996 (L)
Used to transfer information from the memory of the outdoor panel to the TM-key
DS1996 (L). To transfer information, it is necessary to connect the reader (KTM-1P key
reader) to the terminal blocks "TM" and "GND".
To read data from the DS1996 (L), press "1". Then attach the key DS1996 (L) to
the reader, the data transfer will begin. If an error occurs, an error signal will sound. A
sign of the end of the transfer of information is the audio signal of the end of the
recording and the highlight of the right row of buttons in green.
Warning: be sure to wait until the reading is completed correctly, otherwise
the outdoor panel may fail.
Chapter №23 Changing the system code
Used to change the access code to programming mode. After entering the
section, you must type "1", then type the new system code. After dialing the 6th
digit, the new code will be automatically saved.
Chapter №24 Master key recording
Used to record a master key intended for a fast entry into the
programming mode. After entering the section, it is necessary to press: "1" - to
record the master key, "0" - to delete the master key. After entering the
recording mode, you must attach the key to the reader, if the key is red
correctly, the master key will be recorded.
Chapter №25 Return to factory settings.
Used to set the factory settings. After entering the section, you need to
press "1" to confirm the installation, then the parameters will be changed
automatically, and the key database will not change.
Chapter №26 Enabling the Network Protocol
Used to disable the network protocol or set the network number of the
doorphone working on the network. To disable the network protocol, you must
press "0", to enable the network protocol.
10. In versions of the outdoor panel with index V, the built-in video camera can be
powered from external or internal voltage of 12V. For power supply from the internal
source, the terminals "+ UV" and "+ 12V" must be closed.
11. Make a note in the tear-off coupons about the date of commissioning the unit.
If the volume of the call is insufficient, adjust the required parameters (microphone
sensitivity and speaker volume) with trim resistors on the back of the call unit.
If possible, install the power supply in the boxes, niches, at the ceiling. The power
supply must be installed within 15 meters of the outdoor panel. The "EXIT" button
provides opening of the lock when leaving the entrance and is installed near the entrance
door inside the entrance.
To reduce the influence of climatic factors (low temperature, high humidity, frost,
dew), the outdoor panel and the lock should be installed on the second door of the
entrance located in the vestibule.
The cross-sections of the wires connecting the power supply unit to the outdoor
panel and the lock must be at least 0.35 mm2 (KSPV 2х0.64 or CVVC 2х0.5), the rest -
not less than 0.12 mm2. As a connecting wire, it is recommended to use a wire with
colored insulation of cores. To reduce the influence of external influences, the
connection is recommended to be carried out with a shielded cable. For installation of
video equipment use a coaxial cable of the type RK-75.
For doorphones MK20.2 with a network function when installing a digital line
(AV), use a twisted pair. On long communication lines on the "Master" and the last
"Slave" doorphone, install 120 ohm resistors between the terminals AB.
The "+" terminal of the TKP is connected to the bus of tens, and the "-" TKP is
connected to the bus of units. Before connecting the TKP, the line must be checked for a
short circuit. Line resistance should not exceed 30 ohms.
There is protection against short circuit of the line in the doorphone. At this time,
communication with the TKP will be impossible. All other functions are available.
Installation of other doorphone units is carried out in accordance with the passports for
these units.
.