Meteor 8310 Bedienungsanleitung

Fun Imager
(model 8310)
User Manual
v1.01

NOTICE:
This equipment has been tested and complied with
the limits for a Class a digital device, pursuant to
Part 15 of the FCC Rules. These limits are
designed to provide a reasonable protection
against harmful interface when the equipment is
operated under a commercial environment. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may
cause harmful interface to radio communications.
Operation of this equipment in a residential area is
likely to cause harmful interface in which case the
user will be required to correct the interface at his
own expenses.
Note
: All brands and trademarks shall belong to their
respective owner.
This device complies with Part 15 of the FCC
Rules. Operation shall be subject to the following
two conditions:
(1) This device may not cause harmful interface,
and
(2) This device must accept any interface received,
including interface that may cause undesirable
operation.

Note
: Specification is subject to changes without
notice.
Using the Scanner
8110/8150/8250/8310/8312
The Scanner can automatically scan barcode at a
distance. Simply aim and pull the trigger. Code scanning
is performed along the center of the light bar emitted
from the reading window. This bar must cover the entire
code.
Successful scanning shall be obtained by tilting the
scanner with respect to the barcode to avoid direct
reflections that impair the reading performance,
especially for 2D barcode.
Recommended Steps
When the required settings have been configured, all
settings are stored in non- volatile memory of scanner
after reading EXIT Label. Recommended steps are as
follows.
1) Set right host interface for your scanner.
(The scanner is in factory default shown as bold
label)
2) Set interface to optimize protocol of scanner with
your host in interface section.
3) Set system control of scanner, such as specific
adjustments double confirm, power saving, indicator
and scanning mode which you prefer usage in
system control section.
4) Set code options of scanner for your usage in code
option section. You must make sure to enable the
symbology first, then Min./Max. code length, code

ID checksum and truncate digits are also converted.
5) Set string format of the scanner, such as preamble,
postamble Prefix, suffix, code ID and code name
transmission for your application in string format
section.
Note:
If still not work properly. Please contact your dealer
for further information.
CONTENTS
Chapter 1 Introduction
Introduction…………………………..………………. 1
Default Setting ………………………………………. 2
Scanner8110 specification ………..…………….. 4
Scanner8150/8250/8310/8312 specification 7
Programming the Scanner….…………………….. 10
Chapter 2 Parameter Setting
Interface……………………………………………….… 12
Interface Selection ………………………………….. 12
Keyboard wedge ……………………………………. 13
RS-232 …………………………………………….…. 18
Wand Emulation …………………………….………. 21
Pin Assignments ……………………………………. 24
System Control………………………………………. 26
Scan …………………………………………………. 26
Indication …………………………..………………… 30
Code Option…………………………………….……… 32
UPCA ……………………………………..…………. 32
UPCE ………………………………………………… 36
EAN-13 ………………………………………………. 40
EAN-8 ………………………………………………… 44
Code 39 ……………………………………………… 48
Interleaved 2 of 5 …………………………………… 52

Industrial 2 of 5 ……………………………………… 54
Matrix 2 of 5 Eur …………………………………… 56
Codabar ……………………………………………… 58
Code-128 …………………………………………… 61
Code-93 ……………………………………………… 65
Code-11 ………………………………………….…… 68
MSI/Plessey …………………………………………. 70
UK/Plessey ………………………………………….. 72
Telepen ………………………………………………. 74
Standard 2 of 5 ……………………………………… 76
RSS-14 ………………………………………………. 78
RSS-Limited…………………………………..…… 80
RSS-Expanded…………………………………..….. 82
China Post …………………………………………… 84
Italian pharmacode ………………………………… 86
Code 16K …………………………………..………… 88
PDF-417 ……………………………………………… 89
Micro-PDF…………………………………..……….. 91
EAN UCC Composite……………………………….. 93
String Format…………………………………………… 95
String Setting ………………………………………… 95
Transmission ………………………………………… 98
Appendix………………………………………………… 102
Test Chart ……………………………………………. 102
ASCII Code Table …………………………………… 105
Parameter setting List ……………………………….
106

0

1
Introduction
Installation- Keyboard Wedge
1) First of all, you must switch off power for the
terminal/computer.
2) Disconnect the keyboard cable from the back of the
terminal/computer.
3) Connect the appropriate interface cable to the
scanner and to the terminal/computer.
4) Turn the terminal/computer power on.
RS-232
1) Disconnect power to the terminal/computer.
2) Connect the appropriate interface cable and external
power supply (DC adapter) to the scanner.
3) Plug the serial connector into the serial port on the
back of your computer/terminal. Tighten the two
screws to secure the connector to the port.
4) Plug the power pack into power source.
5) Once the scanner has been fully connected, turn the
terminal/computer power back on.
USB (Simulate with keyboard wedge)
1) Connect the USB cable between scanner and PC.
2) Windows will automatically detect the USB device.
Note:
If any of the above operation is incorrect, turn off the
power immediately and checking any improper
connections. Go through all above steps again.

2
Default setting
For each barcode shown as below:
Read
Enable
Code Type
8110
Checksum
Verification
Enable
Checksum
Transmission
Enable
Code
ID
UPC-A V V VA
UPC-E V V VE
EAN-13 V V VF
EAN-8 V V VFF
Code-39 V *
Interleaved
2 of 5 V i
Industrial
2 of 5 - - i
Matrix 2 of 5 B
Codabar V %
Code-128 V V #
Code-93 V two digits &
Code-11 VOne digit O
MSI/Plessey V @
UK/Plessey V @
Te l ep e n S
Standard 2 of
5 - - i
RSS-14 - R4
RSS-Limited - RL
RSS-Expande
d - RX
China Post t
Italian
Pharmacode. p
Code-16K -
PDF417 -
Micro-PDF - U
EAN UCC
Composite - RC

3
Read
Enable
Code Type
8150
8310
8250
8312
Checksum
Verificatio
n
Enable
Checksum
Transmission
Enable
Code
ID
UPC-A V V V VA
UPC-E V V V VE
EAN-13 V V V VF
EAN-8 V V V VFF
Code-39 V V *
Interleaved
2 of 5 V V i
Industrial
2 of 5 - - i
Matrix 2 of 5 B
Codabar %
Code-128 V V V #
Code-93 V two digits &
Code-11 VOne digit O
MSI/Plessey V @
UK/Plessey V @
Te l ep e n S
Standard 2 of 5 V Vi
RSS-14 - R4
RSS-Limited - RL
RSS-Expanded - RX
China Post t
Italian
Pharmacode. p
Code-16K - - -
PDF417 - V - -
Micro-PDF - V8312 - - U

4
EAN UCC
Composite - - - RC
Inhaltsverzeichnis
Andere Meteor Barcode-Lesegerät Handbücher
Beliebte Barcode-Lesegerät Handbücher anderer Marken

POSMicro
POSMicro Datalogic PowerScan D7100 Bedienungsanleitung

Marson
Marson MT780 Kurzanleitung zur Einrichtung

NCR
NCR RealPOS Bedienungsanleitung

Motorola
Motorola SE3300 Kurzanleitung zur Einrichtung

Element
Element P130BT Bedienungsanleitung

Motorola
Motorola Symbol LS3008 Installations- und Betriebshandbuch