
34 ~ 35 —— wired 2nd Defense
Line Wired wide angle sensor, etc.
36 ~ 38 —— wired 24H Defense
Line
Wired emergency button, wired gas
sensor, wired smoke sensor, etc.
NOTE: Each wireless zone can accept 4 groups (group 0, group 1, group 2, group 3), one wireless
sensor takes one group; each wired zone can accept one wired sensor;
C. Detailed program setting
How to get into Program Setting Page: In standby screen, click “MENU”, enter the user code 4 digits
xxxx, and click ENT, now you are in program setting page. Default user code is 8888;
How to set “Date & Time”: In program setting page, click Date & Time, in the new page, click white
blank under Time, Date and Week to make correction.
NOTE: Please delete existing digits by DEL button before you enter the new digits.
How to set “Phone Numbers”: In program setting page, click Phone Numbers, in the new page,
enter phone number for each group by clicking corresponding white blank. And select “Phone#’” or
“SMS” for each group.
NOTE: If you select “Phone#’”, the phone number owner will get the alarm call once system alarms;
if you select “SMS”, the phone number owner will get SMS once system alarms.
* The first group phone number is fixed for CMS, in C ID protocol;
* The 2-5 groups are for personal phone numbers;
How to set “Delay Time”: In program setting page, click Delay Time, in the new page enter new
digits for “Exit Delay” or ”Entry Delay”. Press to confirm new setting;
NOTE: Default setting is 10 seconds, digit range from 00~59.
How to set “Alarm Time”: In program setting page, click Alarm Time, in the new page enter new
digits by clicking the white blank for “Siren in Emergency Zone”, ”Siren in 1st Defense Zone”
or ”Siren in 2nd Defense Zone” after deleting old records. In bellowing setting “Arm/Disarm Beep”, if
YES, system will give beep notification when you Arm/Disarm alarm system; if NO, system won’t
give beep notification when you Arm/Disarm system.
For example, if you enter 02 Minutes for “Motion Siren”, the siren will alarm for 2 minutes when the
sensors in 2nd Defense Line are triggered.
NOTE: Default alarm time is 1 minute, digit range from 00~59.
How to set “Zone Attribute”: In program setting page, click Zone Attribute, in the new page click
white blank of each item to make correction. You can redefine wireless sensor and the
corresponding zone properties. Including Sensor type and Installation position, zone type and zone
function.
* This is to change zone properties and sensor properties, including changes of Zone Code, Sensor
type, Installation position, Zone type, Zone function and Alarm Delay Setting;
* For more details, please refer to “Preview of Zone Info”.
How to set “Smart Zone”: In program setting page, click Smart Zone, in the new page click the white
blank to enter the Zone Code, which you want to set as Smart Zone. Then select Activate YES/NO,
if you select YES, this smart zone will be enabled; and select default door status CLOSE/OPEN, if
you select OPEN, it means the default status of door/window is OPEN in smart zone, usually we