1. General Utilization and Commissioning Directions ________________________________________________________3
1.1 - Storage and Transportation______________________________________________________________________3
1.2 - Installation __________________________________________________________________________________3
1.3 - Electrical Connection ___________________________________________________________________________3
1.4 - Measuring Inputs and Power Supply _______________________________________________________________3
1.5 - Outputs Loading ______________________________________________________________________________3
1.6 - Protection Earthing ____________________________________________________________________________3
1.7 - Setting and Calibration _________________________________________________________________________3
1.8 - Safety Protection______________________________________________________________________________3
1.9 - Handling ____________________________________________________________________________________3
1.10 - Maintenance ________________________________________________________________________________4
1.11 - Waste Disposal of Electrical & Electronic Equipment __________________________________________________4
1.12 - Fault detection and repair ______________________________________________________________________4
2. General Characteristics _____________________________________________________________________________5
2.1 - Power Supply ________________________________________________________________________________5
2.2 - Operation and Algorithms _______________________________________________________________________6
2.2.1 - Reference Input Values _____________________________________________________________________6
2.2.2 - Input quantities ___________________________________________________________________________6
2.2.3 - Time Current Curves IEC (TU1029 Rev.0) _______________________________________________________8
2.2.4 - Time Current Curves IEEE (TU1028 Rev.0) ______________________________________________________9
3. Functions and Settings (Function) ____________________________________________________________________10
3.1 - T> (F49) - Thermal Image protection level_________________________________________________________10
3.1.2 - Thermal Image Curves (TU0445 Rev.0)________________________________________________________11
3.2. - I> (1F51) - First overcurrent protection level ______________________________________________________12
3.3 - I>> (2F51) - Second overcurrent protection level ___________________________________________________13
3.4 - IH (3F51) - Third overcurrent protection level ______________________________________________________14
3.4.2 –Automatic doubling of Overcurrent thresholds on current inrush_____________________________________14
3.5 - Io> (1F51N) - First Earth Fault protection level _____________________________________________________15
3.6 - Io>> (2F51N) - Second Earth Fault protection level __________________________________________________15
3.7 - IoH (3F51N) - Third Earth Fault protection level _____________________________________________________16
3.8 - BF (F51BF) - Breaker Failure____________________________________________________________________16
3.9 - BC (I2/I1) –Broken Conductor __________________________________________________________________17
3.10 –F86 –Lock-out relay_________________________________________________________________________17
3.11 –S Sel –Setting Selection _____________________________________________________________________18
3.12 - I.R.F. - Internal Relay Failure __________________________________________________________________18
3.13 - Osc - Oscillographic Recording _________________________________________________________________19
3.14 - CBMng –Close Breaker Manage ________________________________________________________________19
3.15 - Comm –Communication Parameters ____________________________________________________________20
3.16 - LCD –Display and Buzzer operation _____________________________________________________________20
4. Logic Blocking of Functions _________________________________________________________________________21
4.1 - Blocking outputs _____________________________________________________________________________21
4.2 –Blocking Inputs______________________________________________________________________________21
5. Output Relays ___________________________________________________________________________________21
6. Digital Inputs____________________________________________________________________________________22
7. Self-diagnostic___________________________________________________________________________________22
8. Relay Management _______________________________________________________________________________23
9. Signalizations ___________________________________________________________________________________24
10. Keyboard Buttons _______________________________________________________________________________24
11. Serial Communication Port ________________________________________________________________________25
11.1 - Main RS485 Serial Communication Port __________________________________________________________25
11.2 - Communication Port on Front Face Panel _________________________________________________________26
12. Menu and Variables ______________________________________________________________________________27
12.1 - Real Time Measurements _____________________________________________________________________27
12.2 - Meas (Instantaneous Measurements) ____________________________________________________________27
12.3 - Counter (Operation Counters) __________________________________________________________________28
12.4 - LastTrip (Event Recording) ____________________________________________________________________28
12.5 - R/W Set (Programming / Reading the Relay Settings) _______________________________________________29
12.5.1 - CommAdd (Communication Address)_________________________________________________________29
12.5.2 - Time/Date (Time/Date) ___________________________________________________________________29
12.5.3 - RatedVal (Rated Input Values) ______________________________________________________________29
12.5.4 - Function (Functions)______________________________________________________________________30
12.6 - RelayCfg (Relay Configuration) _________________________________________________________________32
12.7 - Commands ________________________________________________________________________________32
12.8 - Info&Ver (Firmware - Info&Version) _____________________________________________________________32
13. Keyboard Operational Diagram _____________________________________________________________________33
14. Password ______________________________________________________________________________________34
14.1 - MS-Com Password___________________________________________________________________________34
15. Maintenance ___________________________________________________________________________________34
16. Power Frequency Insulation Test ____________________________________________________________________34
17. Connection Diagram _____________________________________________________________________________35
18. Overall Dimensions ______________________________________________________________________________35
19. Direction For Pcb's Draw-Out And Plug-In _____________________________________________________________36
19.1 - Draw-Out _________________________________________________________________________________36
19.2 - Plug-In ___________________________________________________________________________________36
20. Electrical Characteristics __________________________________________________________________________37