Mikra M15 Bedienungsanleitung

TABLE OF CONTENTS
OPERATION OVERVIEW AND GENERAL INTRODUCTION ..................................... 1
INTRODUCTION .......................................................................................................... 2
MANUAL MODE .......................................................................................................... 3
SINGLE MODE ............................................................................................................ 3
PRE-SET PROGRAM (10 SETS)................................................................................. 4
PROGRAM LOCK AND OPEN(10 SETS) ................................................................... 5
FAST PROGRAM......................................................................................................... 6
FINE ADJUSTMENT .................................................................................................... 6
LOAD DATUM VALUES............................................................................................... 7
SELECT COUNTING DIRECTION(+/-) ........................................................................ 8
RESOLUTION .............................................................................................................. 9
SENSOR CALIBRATION ........................................................................................... 10
SET PARAMETER ..................................................................................................... 11
PARAMETER ............................................................................................................. 12
PARAMETER LOCK AND OPEN .............................................................................. 13
TROUBLESHOOTING ............................................................................................... 14
INSTALLATION GUIDE ............................................................................................. 16
POWER SUPPLY & HARDWARE ............................................................................. 18
EXTERNAL DIMENSION ........................................................................................... 19

1
Operation Panel
LED / KEY Description KEY Description KEY Description
Upper Window
Target value
Manual / Single
mode Parameter
Upper LED Target value
LED Program mm / inch
Lower Window
Current value
Active Clear / Return
Lower LED Current value
LED Stop / Cancel
Confirm / Enter
0 ~ 9 Number keys
+ / - Decimal
Note: Display : LED on / blinks
Upper Window
Lower Window LED lamp

2
Introduction
Function:
1.
One or two speed positioning 7. Resolution: 0.1mm/ 0.05mm/ 0.01mm
2.
Manual / Single mode 8. Correct zero point
3.
10 sets single program 9. Display: RPM speed
4.
10 sets tool offsets 10.
Protection for tool / motor fault
5.
Quick program / Fine Adjustment 11.
Battery life 2.5 year
6.
Inch / mm conversion 12.
Self-diagnose
Specification:
1
Housing: 115w ×115h ×80d (mm)
2
Panel cut out: 93w ×67h (mm)
3
Mounting screws: M3 ×4 104 ×104 (mm)
4
Supply voltage: 24VDC/50mA/, C type battery (1.5V) ×1
5
Battery voltage control: Low battery alarm
6
Sensor cable length: 3m
7
Thermal expansion: α= 16 ×10
-6
×1/K
8
Gap sensor/strip: max. 2.5mm
9
Display: 15mm LED ×6 digits ×2 line
10
Output: 4 digital output
(AC250V / 7A;DC24V/10A)
11
Input: 4 digital input(24VDC)
12
Operating elements: 20 button keyboard
13
Test mark/ interfere
.Protection class: 3 accord. to IEC 801
14
Travel Speed: 1.5m/s
15
System accuracy: ±(0.025+0.02L)mm, L: Meter)
16
Repeatability: 0.01mm
17
Temperature: Operating temperature 0 + 50, Storage temperature –20
+70℃
18
Humidity: max. 95% rF(Condensation not permitted)

3
Manual Mode
Description: To move the machine table by pressing M15 keyboard.
fast forward backward fast
Example: M15 displays 100.00mm, to move the machine table:
Note: Be sure in “※manual” mode. (LED lamp of “manual / Single” key is blinking) The
upper window shows “HAnd” mode.
Press to move machine table forward
(fast).
Press to move machine table backward (fast).
Note: Press or for forward/ backward/
lower speed (depends on machine and wiring).
Single Mode
Description: M15 can execute auto positioning.
Example: M15 current value is 100.00mm, to reach 200mm (setting target value).
Step1. Select single mode LED lamp is off.
Step2. Press , blinking, enter new target
value
LED lamp is off, complete.
※Note: During positioning, press to stop;
to re-start, press and
7
F
98
100.00
100.00
200.00
100.00
STOP
PROG
PROG
8
9
F
7
2 0 0
= H A n d
106.80
H A n d =
96.80

4
Pre-Set Program (10 sets)
Description: Pre-set program 10 sets, enter program # 0~9 to execute.
Example: Program 1=10mm, Program 2=20.00mm.
Step1. Press
select enter a key (0-9, total of 10sets).
Note: Be sure in manual mode.※
Step2. (Enter program 1=10mm), press
more press .
Step3. Target value display: ProG_at present,
enter program 2=20.00mm, press to
exit.
1
10
ProG
1
ProG
ProG
F 5 5
1 0

5
Program Open and Lock (10 sets)
Description: Don’t needs pre-set program, to start or close.
Example: Program 1=10.00mm for , program 2= 20.00mm for ,
~ other a key, don’t setting pre-set program, to stop follow
steps as below:
Step1. Press
target value display: ProG_ .
Note: Be sure in single mode.※
Step2. Press
current value display:_ _ _ _ _ _, closed,
frame display, started.
Step3. Press to close
※Note: To close other keys, follow the step 2, 3.
0 1
92
5
55
5
5
55
5
F
2
STOP
2
2
2
20.00
ProG
2
ProG
ProG

6
START
Fast Program
Description: To facilitate frequently used positions, the keys 0 to 9 have associated
preset target values. And the positioning can be started immediately.
Example: Program 1=10.00mm, program 2=20.00mm. Execute program 2 as below:
Step1. Select singe mode LED lamp off.
Step2. Press target value display: 20.00mm
LED blinking, to waitting start.
※Note: Execute program1 press#1.
Fine Adjustment
Description: Increase and decrease to reach fine adjustment.
Example: M15 target value display100.78mm, increase/ decrease target value0.25mm,
setting steps as below:
Step1. Increase target value: press
display 0.00 LED blinking,
decrease: press twice,
display-0.00 LED blinking.
Step2. Press
press to completed.
※Note: Target value display: 101.03mm, current value
display:100.78mm for target value increase
0.25mm.
2
50 2
+/-
+/-
100.00
100.00
20.00
100.00
0.00
100.00
100.00
0.25

7
Load datum values
A. Description: To load current value according to working piece.
Example: M15 current value display100.00mm, actual size: 100.50mm, follow the
steps as below:
Step1. Select singe mode LED lamp off.
Step 2. Press , enter new
value, press
press , to exit.
B. How to show the new set value:
Step1. Press , press twice,
display new value.
100.00
OriGin
100.00
100.00
F 0
100.00
2
F
1 0
0 5
F 0

8
Select Counting Direction(+/-)
Description:To select the counting direction.
Example:M-15 current value display: 100.00mm, sensor forward for decrease value
99.68mm, but hope value become big, value increase follow the steps as
below:
Step1. Press back single mode, LED lamp off.
Step 2. Press
target value display origin parameter value “-dir”
(select counting direction parameter).
Step 3. Press to select the direction, -dir / dir
(or"-dir" for left or "dir- " for right.)
Step 4. Press to complete, and exit.
100.00
99.68
F 1
99.68
-
dir
100.00
99.68
1
F
PROG
Andere Handbücher für M15
1
Inhaltsverzeichnis
Andere Mikra Controller Handbücher