Mitsubishi Electric REMOTE STATUS ALARM PANEL Bedienungsanleitung

W3-002-SLSUPS-002A
REMOTE STATUS ALARM PANEL
INSTALLATION/INSTRUCTION MANUAL
RSAP
Mitsubishi Electric Automation, Inc.
UPS Group

10/13/04 1 93120-MAN07
Table of Contents
Physical Characteristics..................................................................... 2
Installation instructions...................................................................... 2
Operating instructions........................................................................ 3
Remote Monitor Closed (Figure 1.0)…............................................. 4
Remote Monitor Closed Hardwired (Figure 1.1)............................... 5
Terminal Block Description (Figure 2.0)........................................... 6
Terminal Block Description Hardwired (Figure 2.1)......................... 7
Remote Monitor Open (Figure 3.0)…................................................ 8
Remote Monitor Open Hardwired (Figure 3.1).................................. 9
Remote Monitor Conduit Access (Figure 4)….................................. 10
Figure 2033A (Analog) UPS ............................................................. 11
Figure 2033A (DDC) UPS …............................................................ 12
Figure 2033C UPS …………............................................................. 13
Figure 2033D/9800AD UPS ..................………................................ 14
Figure 9700 Series ............................................................................. 15
Figure 9800A UPS ............................................................................. 16

10/13/04 2 93120-MAN07
Physical Characteristics
Weight: 10lbs (4.5 kgs.)
Height: 81/4 inches (210 mm)
Width: 8 5/16 inches (211 mm)
Depth: 4 5/16 inches (110 mm)
Installation
1. Locate the area where the Remote Status Alarm Panel (RSAP) will be installed. The
monitor should be within 300 feet (91 meters) of the UPS.
2. Mount the monitor to the wall using the four pre-drilled holes in the back. Use
appropriate hardware for the installation.
3. Wiring requirements are: 7 twisted pair 16 AWG cable run in metal conduit. Use Belden
Catalog No. 1485B (8 twisted pair) or equivalent. All electrical and mechanical
connections to be made per local and/or national electric codes.
4. Connect the conduit to the RSAP by punching the appropriately sized hole in a
convenient location.. Caution! Care should be taken not to damage any internal
components when drilling hole for conduit.
5. Refering to Figure 2.0, 3.0, and the corresponding UPS wiring diagram, connect the
seven (7) pairs of twisted wire from the RSAP to the customer accessible alarm contact
terminal bar in the UPS module. (Refer to the UPS’ owner’s manual for location)
6. Refering to Figure 3.0, install (6) AA batteries (included). Batteries will provide about 8
hours of run time in the event of an AC power failure. Replace these batteries yearly for
optimum performance.
7. Refering to Figure 1.0, connect the power supply adapter into the corresponding jack
located on the bottom left-hand side of the RSAP enclosure. Plug the power supply into a
convenient 120V/60Hz wall receptacle. Failure to connect to a suitable wall outlet will
drain the RSAP’s internal batteries and/or result in damage to the monitor. (If supplied
with the hardwire version, please refer to Figure 3.1 for AC input terminal block layout.
Connect L1, Neutral, and Ground with minimum of 18awg wire.)
Caution! The monitor must be installed by a qualified electrician. Installation to be inspected
by an Authorized UPS Service Engineer at the time of UPS startup.

10/13/04 3 93120-MAN07
Operating Instructions
ALARM SILENCE pushbutton is used to silence the alarm.
MONITOR RESET pushbutton is used to reset the RSAP’s UPS FAULT alarm. The monitor will alarm
again if the alarm condition is still present following the RESET.
Monitor TEST pushbutton is used to check the operation of all LED's and the audible alarm. All LED’s
that are illuminated will go off and all lights that are off will illuminate. Horn will also sound.
INTERNAL MONITOR BATTERY TEST button is used to test the condition of the monitor's battery
pack. If the yellow LED does not illuminate, replace the batteries.
Reset the RSAP as follows:
1. On the UPS, note the alarm and it’s fault code. If applicable, contact 24 hour UPS field service at
(800) 887-7830.
2. If no alarm code is present, press the monitor reset button.
3. If the monitor's audible alarm sounds again repeat steps 1and 2.
4. Contact Mitsubishi service if the alarm cannot be reset after a few attempts.
Refer to Figure 1.0 for the location of the LED's and pushbuttons described below:
1. Rectifier / Charger LED. This green LED is illuminated as long as the UPS’ inverter is
operating.
2. Battery LED. This yellow LED is illuminated as long as the UPS is in the battery backup mode.
The audible alarm will beep intermittently.
3. Inverter On LED. The green LED is illuminated as long as the UPS’ inverter is operating.
4. Output LED. This green LED is illuminated as long as there is power to the critical load. (either
by the Inverter or Bypass)
5. Load On Bypass LED. This yellow LED is illuminated as long as the critical load is powered
by the Bypass.
6. AC Input LED. This green LED is illuminated as long as there is AC power supplied to the
system.
7. UPS Fault. This Red LED is illuminated and the audible alarm sounds when a UPS fault has
occurred. The RSAP must be reset after the alarm is cleared.
8. Overload LED. This red LED is illuminated when a UPS overload has occurred. The audible
alarm will also sound.
9. Input Failure LED. This red LED is illuminated when an input power failure condition is
present. The audible alarm will also sound.
10. Battery Low Voltage. This red LED is illuminated as soon as the DC bus voltage approaches its
cutoff voltage. The audible alarm will also sound.
11. Alarm Silence LED. This LED will illuminate when the ALARM SILENCE pushbutton has
been pressed and alarm condition is still present. If alarm condition clears, the ALARM
SILENCE LED will automatically reset.
12. Internal Monitor Battery OK LED. This yellow LED will illuminate when it's corresponding
push button is pressed and the batteries are OK. If this light is dim or does not light, replace all
internal batteries.

10/13/04 4 93120-MAN07
UPS FAULT
OVERLOAD
INPUT FAILURE
BATTERY LOW
VOLTAGE
ALARM SILENCE
INTERNAL MONITOR
BATTERY OK
MONITOR RESET
MONITOR TEST
ALARM SILENCE
INTERNAL MONITOR
BATTERY TEST
BYPASS
INPUT
OUTPUT
1. RECTIFIER ON (GREEN LED)
6. AC INPUT ON (GREEN LED)
7. UPS FAULT (RED LED)
8. OVERLOAD (RED LED)
9. INPUT FAILURE (RED LED)
10. BATTERY LOW VOLTAGE (RED LED)
11. ALARM SILENCE (RED LED)
12. INTERNAL MONITOR BATTERY
OK (YELLOW LED)
5. LOAD ON BYPASS (YELLOW LED)
4. OUTPUT TO CRITICAL LOAD (GREEN LED)
3. INVERTER ON (GREEN LED)
2. BATTERIES ON (YELLOW LED)
AUDIBLE ALARM
MONITOR RESET PUSHBUTTON
MONITOR TEST PUSHBUTTON
ALARM SILENCE PUSHBUTTON
INTERNAL MONITOR BATTERY TEST PUSHBUTTON
INPUT TRANSFORMER
FEMALE MIC PLUG
6' CORD
FIGURE 1.0
INPUT CONFIGURATION
(SEE OPTIONS)
OPTIONS: VARIOUS INPUT CONFIGURATIONS ARE AVAILABLE FOR THE
UPS REMOTE MONITOR. PLEASE CONSULT THE FACTORY ABOUT YOUR
PARTICULAR APPKICATION.

10/13/04 5 93120-MAN07
UPS FAULT
OVERLOAD
INPUT FAILURE
BATTERY LOW
VOLTAGE
ALARM SILENCE
INTERNAL MONITOR
BATTERY OK
MONITOR RESET
MONITOR TEST
ALARM SILENCE
INTERNAL MONITOR
BATTERY TEST
BYPASS
INPUT
OUTPUT
1. RECTIFIER ON (GREEN LED)
6. AC INPUT ON (GREEN LED)
7. UPS FAULT (RED LED)
8. OVERLOAD (RED LED)
9. INPUT FAILURE (RED LED)
10. BATTERY LOW VOLTAGE (RED LED)
11. ALARM SILENCE (RED LED)
12. INTERNAL MONITOR BATTERY
OK (YELLOW LED)
5. LOAD ON BYPASS (YELLOW LED)
4. OUTPUT TO CRITICAL LOAD (GREEN LED)
3. INVERTER ON (GREEN LED)
2. BATTERIES ON (YELLOW LED)
AUDIBLE ALARM
MONITOR RESET PUSHBUTTON
MONITOR TEST PUSHBUTTON
ALARM SILENCE PUSHBUTTON
INTERNAL MONITOR BATTERY TEST PUSHBUTTON
FIGURE 1.1
(INTERNAL POWER SUPPLY / HARDWIRE OPTION)

10/13/04 6 93120-MAN07
-AC INPUT L1 (OPTION)
-BYPASS (CLOSES WHEN ON BYPASS)
-BYPASS COMMON
-INVERTER (CLOSES WHEN INVERTER IS RUNNING)
-INVERTER COMMON
-ON BATTERIES (CLOSES WHEN ON BATTERIES)
-BATTERY COMMON
-RECTIFIER (CLOSES WHEN RECTIFIER IS RUNNING)
-RECTIFIER COMMON
-UPS FAILURE (CLOSES ON UPS FAILURE)
-UPS COMMON
-LOW BATTERY (CLOSES WHEN BATTERIES ARE LOW)
-LOW BATTERY COMMON
-OVERLOAD (CLOSES WHEN IN OVERLOAD)
-OVERLOAD COMMON
-AC INPUT L1 (OPTION)
1
2
3
4
5
7
8
6
9
16
15
14
11
13
12
10
TB1
TERMINAL BLOCK DESCRIPTION
(LOCATED INSIDE BOX)
FIGURE 2.0

10/13/04 7 93120-MAN07
-BYPASS
-BYPASS COMMON
-INVERTER (CLOSES WHEN INVERTER IS RUNNING)
-INVERTER COMMON
-ON BATTERIES (CLOSES WHEN ON BATTERIES)
-BATTERY COMMON
-RECTIFIER (CLOSES WHEN RECTIFIER IS RUNNING)
-RECTIFIER COMMON
-UPS FAILURE (CLOSES ON UPS FAILURE)
-UPS COMMON
-LOW BATTERY (CLOSES WHEN BATTERIES ARE LOW)
-LOW BATTERY COMMON
-OVERLOAD (CLOSES WHEN IN OVERLOAD)
-OVERLOAD COMMON
-NOT USED4
5
7
8
6
9
16
15
14
11
13
12
10
TERMINAL BLOCK DESCRIPTION
(LOCATED INSIDE BOX)
FIGURE 2.1
(INTERNAL POWER SUPPLY / HARDWIRE OPTION)
-AC LINE INPUT L1
-AC NEUTRAL INPUT
-GROUND
3
2
1
17
18

10/13/04 8 93120-MAN07
2 AC INPUT L1 (OPTION)
3 BYPASS
4 BYPASS COMMON
5 INVERTER
6 INVERTER COMMON
7 ON BATTERIES
8 BATTERY COMMON
9 RECTIFIER
10 RECTIFIER COMMON
11 UPS FAILURE
12 UPS COMMON
13 LOW BATTERY
14 LOW BATTERY COMMON
15 OVERLOAD
16 OVERLOAD COMMON
1 AC INPUT L1 (OPTION)
BATTERY
ARRANGEMENT
TERMINAL BLOCK
LABELS
6"
6"
.312"Ø MOUNT HOLES
CIRCUIT BOARD
BATTERY HOLDER
INPUT PLUG
INPUT TRANSFORMER
(12 VOLT DC OUTPUT)
FIGURE 3.0

10/13/04 9 93120-MAN07
TERMINAL BLOCKS LABELS
6"
6"
.312"Ø MOUNT HOLES
CIRCUIT BOARD
BATTERY HOLDER
FIGURE 3.1
(INTERNAL POWER SUPPLY / HARDWIRE OPTION)
BATTERY
ARRANGEMENT
11 RECTIFIER
15 LOW BATTERY
14 UPS COMMON
13 UPS FAILURE
17 OVERLOAD
18 OVERLOAD COMMON
16 LOW BATTERY COMMON
12 RECTIFIER COMMON
3 GROUND
7 INVERTER
6 BYPASS COMMON
4 NOT USED
9 ON BATTERIES
10 BATTERY COMMON
8 INVERTER COMMON
5 BYPASS
2 AC NEUTRAL INPUT
1 AC LINE INPUT L1
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Beliebte Sicherheitssystem Handbücher anderer Marken

EDM
EDM Solution 6+6 Wireless-AE Bedienungsanleitung

Highway Safety Group
Highway Safety Group EA401 Bedienungsanleitung

Siren
Siren LED GSM Bedienungsanleitung

Detection Systems
Detection Systems 7090i Montageanleitung

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Bedienungsanleitung

Siemens
Siemens FDM273 Bedienungsanleitung











