the box. Install the service panel correctly.
,QFRUUHFWLQVWDOODWLRQPD\UHVXOWLQRYHUKHDWLQJ
DQG¿UH
Do not perform brazing work in the
airtight room.
,WFDQFDXVHODFNRIR[\JHQ
Use the prescribed pipes, flare nuts
and tools for R410A.
8VLQJH[LVWLQJSDUWVIRU5RU5&FDQ
FDXVHWKHXQLWIDLOXUHDQGVHULRXVDFFLGHQWVGXHWR
EXUVWRIWKHUHIULJHUDQWFLUFXLW
Tighten the flare nut by using double
spanners and torque wrench according
to prescribed method. Be sure not to
tighten the flare nut too much.
/RRVHÀDUHFRQQHFWLRQRUGDPDJHRQWKHÀDUHSDUW
E\WLJKWHQLQJZLWKH[FHVVWRUTXHFDQFDXVHEXUVW
RUUHIULJHUDQWOHDNVZKLFKPD\UHVXOWLQODFNRI
R[\JHQ
Do not open the service valves for
liquid line and gas line until completed
refrigerant piping work, air tightness
test and evacuation.
,IWKHFRPSUHVVRULVRSHUDWHGLQVWDWHRIRSHQLQJ
VHUYLFHYDOYHVEHIRUHFRPSOHWHGFRQQHFWLRQRI
UHIULJHUDQWSLSLQJZRUNDLUFDQEHVXFNHGLQWR
UHIULJHUDQWFLUFXLWZKLFKFDQFDXVHEXVWRU
SHUVRQDOLQMXU\GXHWRDQRPDORXVO\KLJKSUHVVXUH
LQWKHUHIULJHUDQW
Do not put the drainage pipe directly into
drainage channels where poisonous
gases such as sulphide gas can occur.
3RLVRQRXVJDVHVZLOOÀRZLQWRWKHURRPWKURXJK
GUDLQDJHSLSHDQGVHULRXVO\DIIHFWWKHXVHU¶V
KHDOWKDQGVDIHW\
Only use prescribed optional parts.
The installation must be carried out by
the qualified installer.
,I\RXLQVWDOOWKHV\VWHPE\\RXUVHOILWFDQFDXVH
VHULRXVWURXEOHVXFKDVZDWHUOHDNVHOHFWULF
VKRFNV¿UH
Do not run the unit with removed panels
or protections
7RXFKLQJURWDWLQJHTXLSPHQWVKRWVXUIDFHVRU
KLJKYROWDJHSDUWVFDQFDXVHSHUVRQDOLQMXU\GXH
WRHQWUDSPHQWEXUQRUHOHFWULFVKRFNV
Be sure to fix up the service panels.
,QFRUUHFW¿[LQJFDQFDXVHHOHFWULFVKRFNVRU
¿UHGXHWRLQWUXVLRQRIGXVWRUZDWHU
Do not perform any repairs or modifi-
cations by yourself. Consult the dealer
if the unit requires repair.
,I\RXUHSDLURUPRGLI\WKHXQLWLWFDQFDXVHZDWHU
Safety precautions
Hang up the unit at the specified points
with ropes which can support the
weight in lifting for portage. And to
avoid jolting out of alignment, be sure to
hang up the unit at 4-point support.
$QLPSURSHUPDQQHURISRUWDJHVXFKDVSRLQW
VXSSRUWFDQFDXVHGHDWKRUVHULRXVSHUVRQDOLQMXU\
GXHWRIDOOLQJRIWKHXQLW
Install the unit in a location with good
support.
8QVXLWDEOHLQVWDOODWLRQORFDWLRQVFDQFDXVHWKH
XQLWWRIDOODQGFDXVHPDWHULDOGDPDJHDQG
SHUVRQDOLQMXU\
Ensure the unit is stable when installed,
so that it can withstand earthquakes
and strong winds.
8QVXLWDEOHLQVWDOODWLRQORFDWLRQVFDQFDXVHWKH
XQLWWRIDOODQGFDXVHPDWHULDOGDPDJHDQG
SHUVRQDOLQMXU\
Ensure that no air enters in the refriger-
ant circuit when the unit is installed
and removed.
,IDLUHQWHUVLQWKHUHIULJHUDQWFLUFXLWWKHSUHVVXUH
LQWKHUHIULJHUDQWFLUFXLWEHFRPHVWRRKLJKZKLFK
FDQFDXVHEXUVWDQGSHUVRQDOLQMXU\
The electrical installation must be
carried out by the qualified electrician
in accordance with “the norm for
electrical work” and “national wiring
regulation”, and the system must be
connected to the dedicated circuit.
3RZHUVXSSO\ZLWKLQVXIILFLHQWFDSDFLW\DQG
LQFRUUHFWIXQFWLRQGRQHE\LPSURSHUZRUNFDQ
FDXVHHOHFWULFVKRFNVDQG¿UH
Be sure to shut off the power before
starting electrical work.
)DLOXUHWRVKXWRIIWKHSRZHUFDQFDXVHHOHFWULF
VKRFNVXQLWIDLOXUHRULQFRUUHFWIXQFWLRQRI
HTXLSPHQW
Be sure to use the cables conformed
to safety standard and cable ampacity
for power distribution work.
8QFRQIRUPDEOHFDEOHVFDQFDXVHHOHFWULFOHDN
DQRPDORXVKHDWSURGXFWLRQRU¿UH
Use the prescribed cables for electrical
connection, tighten the cables securely
in terminal block and relieve the
cables correctly to prevent overloading the
terminal blocks.
/RRVHFRQQHFWLRQVRUFDEOHPRXQWLQJVFDQFDXVH
DQRPDORXVKHDWSURGXFWLRQRU¿UH
Arrange the wiring in the control box so
that it cannot be pushed up further into