MRC MVB-385SD Bedienungsanleitung

SD card real time data recorder
Acceleration , Velocity .
VIBRATION DATA RECORDER
Model : MVB-385SD Your purchase of this
VIBRATION DATA
RECORDER marks a
step forward for you
into the field of
precision measurement.
Although this Meter is a
complex and delicate
instrument, its durable
structure will allow
many years of use if
proper operating
techniques are
developed. Please read
the following
instructions carefully
and always keep this
manual within easy
reach.
OPERATION MANUAL
PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION
Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529
mrc@mrclab.com MRC.8.22

TABLE OF CONTENTS
1. FEATURES...............................................................................
................................
1
2. SPECIFICATIONS.................................................................................
....................
2
3. FRONT PANEL DESCRIPTION....................................................
.............................
5
4. MEASURING PROCEDURE................................................
.......................
6
5. DATALOGGER......................................................................................
.....................
9
5-1 Preparation before execute datalogger function...............................................................................
9
5-2 Datalogger...........................................................................
....................................
11
5-3 Check time information.........................................................................................
12
5-4 SD Card Data structure.................................................................................
12
6. Saving data from the SD card to the computer.......................................
.......................
13
7. ADVANCED SETTING.............................................................
.........................................
14
7-1 Set clock time ...................................................................................
.......................
15
7-2 Set sampling time......................................................
.....................................
15
7-3 Set Auto Power OFF ...................................................
.......................................
16
7-4 Set beeper sound ON/OFF.........................
..................................................
16
7-5 Set SD card Decimal character...........................................
............................
17
7-6 SD memory card Format.........................................................
...............................
17
7-7 Set UNIT ............................................................................................
..............
18
8. POWER SUPPLY from DC ADAPTER.............................................
.....................
19
9. BATTERY REPLACEMENT...........................................................
...............
19
10. SYSTEM RESET..............................................................
.................................
19
11. RS232 PC serial interface.................................................................................
20
12. PATENT......................................................................................
.................
22

1. FEATURES
* Applications for industrial vibration monitoring :
All industrial machinery vibrates. The level of vibration is
a useful guide to machine condition. Poor balance,
misalignment & looseness of the structure will cause the
vibration level increase, it is a sure sign that the
maintenance is needed.
* Frequency range 10 Hz – 1kHz, sensitivity relative meet
IOS 2954.
* Profressional vibration meter supply with vibration sensor
& magnetic base, full set.
* Metric & Imperial display unit.
* Acceleration, Velocity measurement.
* RMS, Max hold , Peak value measurement.
* Max. Hold reset button, Zero button.
* Wide frequency range.
* Data hold button to freeze the desired reading.
* Memory function to record maximum and minimum
reading with recall.
* Separate vibration probe with magnetic base, easy operation.
* Real time SD memory card Datalogger, it Built-in Clock
And Calendar,real time data recorder, sampling time set
From 5 second to 3600 seconds.
* Innovation and easy operation, computer is not need
to setup extra software, after execute datalogger, just
take away the SD card from the meter and plug in the
SD card into the computer, it can down load the all the
measured value with the time information(
year/month/date/hour/minute/second) to the Excel
directly, then user can make the further data or graphic
analysis by themselves.
* SD card capacity : 1 GB to 16 GB.
1

* LCD with green light backlight, easy reading.
* Can default auto power off or manual power off.
* Data hold, record max. and min. reading.
* Microcomputer circuit, high accuracy.
* Power by UM4/AAA( 1.5V ) x 6 batteries or DC 9V adapter.
* RS232/USB PC COMPUTER interface.
2. SPECIFICATIONS
2-1 General Specifications
Circuit Custom one-chip of microprocessor LSI
circuit.
Display LCD size : 60 mm x 50 mm
Measurement Acceleration,Velocity,Displacement
Memory Card SD memory card. 1 GB to 16 GB.
Datalogger 5/10/30/60/120/300/600/1800/3600 seconds
Sampling Time
Data error no. ≦ 0.1 % no. of total saved data typically.
Advanced * Set clock time ( Year/Month/Date, Hour/Minute/
setting Second )
* Set sampling time
*Set Auto Power OFF
* Set beeper sound ON/OFF
* Set SD card Decimal character
* SD memory card Format
* Set UNIT
Update Time Approx. 1 second if measuring data
of Display is changed.
2

Data Output RS 232/USB PC computer interface.
* Connect the optional RS232 cable
UPCB-02 will get the RS232 plug.
* Connect the optional USB cable
USB-01 will get the USB plug.
Operating 0 to 50 ℃.
Temperature
Operating Less than 85% R.H.
Humidity
Power Supply *DC 9V adapter input. ( AC/DC power
* Meter & adapter is included ).
probe
Power Supply *Alkaline or heavy duty DC 1.5 V battery
* Clock backup ( UM4, AAA ) x 6 PCs, or equivalent.
probe
battery
Weight 199 g/0.44 LB.
Dimension 132 x 80 x 32 mm
( 5.2 x 3.1 x 1.3 inch )
Accessories * Instruction manual.............................. 1 pcs.
Included * Vibration Sensor(VB-81A).................. 1 pcs.
*
SKT-AS385(mA output socket)................................................
1 pcs.
Optional * SD Card ( 4 GB )
Accessories * 2 wires pressure transmitter, TR-PS2W
* USB cable, USB-01.
* RS232 cable, UPCB-02.
* Data Acquisition software, SW-U801-WIN.
* Excel Data Acquisition software, SW-E802.
* AC-AP9VA (AC to DC 9V adapter)
3

2-2 Electrical Specifications (23±5
℃
)
Function Unit Range and Resolution Accuracy
Acceleration m/s2 0.5 to 199.9 m/s2
g 0.05 to 20.39 G ± ( 5%rdg + 2 d )
ft/s2 2 to 656 ft/s2 @ 80 and 160Hz
Calibration Point: 50 m/S^2 ( 160 Hz )
Velocity mm/s 0.5 to 199.9 mm/s
cm/s 0.05 to 19.99 cm/s ± ( 5%rdg + 2 d )
inch/s 0.02 to 7.87 inch/s @ 80 and 160Hz
Calibration Point: 50 mm/s ( 160 Hz )
Above specification tests under the environment RF Field Strength
less than 3 V/M & frequency less than 30 MHz only and 23°C ±0.5°C
4

3. FRONT PANEL DESCRIPTION
Fig. 1
3-1 Display 3-12 Battery cover/Battery compartment
3-2 Power button ( Backlight button ) 3-13 Screw of the battery cover
3-3 ▲ Button ( Unit Button ) 3-14 Hanging unit ( with sticker )
3-4 REC Button ( HOLD Button ) 3-15 Reset Button
3-5 SET Button ( Time Button ) 3-16 RS-232 Output Terminal
3-6 ▼ Button ( Function Button ) 3-17 SD card socket
3-7 Logger button ( Enter button ) 3-18 4-20 mA Output Terminal
3-8 Vibration Sensor input BNC socket 3-19 Reset Button
3-9 DC 9V power adapter input socket 3-20 Vibration Sensor
3-10 Hanging holes 3-21 Vibration Sensor BNC
3-11 Stand
5

4. MEASURING PROCEDURE
1) Power supply installation :
* The meter's power supply should install the batteries
and connect " AC to DC adapter " together.
* The batteries are the power of " Clock ".
Batteries
Install the batteries into the battery compartment :
* Loose the " Screw of the battery cover " ( 3-13, Fig. 1 )
and take away the " Battery Cover " ( 3-12, Fig. 1 ) from
the meter.
* Replace with DC 1.5 V battery ( UM4/AAA, Alkaline/Heavy
duty type ) x 6 PCs, and reinstate the cover.
* Make sure the battery cover is secured after changing
the battery.
AC to DC adapter
* The " AC to DC adapter " is the standard accessory.
* Plug the output plug of " AC to DC adapter " into
the " DC 9V power adapter input socket " ( 3-9, Fig. 1 )
2) Vibration Sensor
Connect the vibration pickup to the cable supplied
Make sure it is firmly attached. Connect the cable
to the meter by attaching it to the "BNC connector( 3-8, Fig. 1 )
on the Bottom of the meter.If the surface to be tested is magnetic,
attach the magnetic base to the vibration pickup and attach the
pickup to a flat surface.If the surface to be tested is not magnetic,
hold the pickup against the surface. Do not hold the cable while
making measurements.
6

3) Vibration unit
The currently selected unit of measure is shown on the
meter’s LCD. To change the unit of measure, press and hold
the ▲ Button " Unit Button ( 3-3, Fig. 1 )" until the desired unit
of measure appears and then release the button.
if want change metric or imperial please refer chapter 7-7 (page 18 ).
4) Function Selection
The currently selected function is shown on the meter’s
LCD. To change the function, press and hold the button.
"FUNCTION button( 3-6, Fig. 1 )" until the desired function
appears, then release the FUNCTION .
The available functions are:
RMS: Typical selection for Acceleration and Velocity
PEAK: Displays the peak value of the vibration
MAX HOLD: Displays and holds the max value measured
MAX HOLD Reset:
Press and hold the ▲ and ▼ buttons for > 3 seconds to clear the
Max. Hold reading.
7

5) Data Hold:
To freeze a displayed reading on the LCD, momentarily press
the"HOLD button ( 3-4, Fig. 1 )" (the HOLD icon will appear
above the reading). To exit HOLD, press the HOLD button again.
6) ZERO Adjustment
The ZERO function is used to remove any small offset caused
by temperature changes or other environmental changes.
The zero will only work for a display of 10 or less digits.
1. Connect the vibration sensor to the meter
2. Set the measurement function to Acceleration
3. Make sure the sensor is motionless and not subject to
any vibrations.
4. Press and Hold the ▼ and ▲buttons for 3 seconds and the
meter will show zero .
7) REC ( Record):
For a given measurement session, this meter can record the
highest (MAX) and the lowest (MIN) readings for later recall.
1. Press the REC button momentarily to access this mode
of operation (REC icon appears)
2. The meter is now recording the MAX and MIN readings.
3. Press the REC button again to view the current
MAX readings (MAX icon appears). The readings on the
display are now the highest readings encountered since
the REC icon wasswitched on (when the MAX-MIN button
was first pressed).
4. Press the REC button again to view the current MIN
readings (MIN icon appears). The readings on the display
are now the lowest readings encountered since the REC icon
was switched on (when the REC button was first pressed).
5. To exit the MAX-MIN mode, press and hold the REC
button for 3 seconds. The meter will beep, the REC-MAX-MIN
icons will switch off, the MAX-MIN memory will clear,
and the meter will return to the normal operating mode.
8
Inhaltsverzeichnis
Andere MRC Datenlogger Handbücher
Beliebte Datenlogger Handbücher anderer Marken

Athena
Athena GET SL1 Bedienungsanleitung

Motec Systems
Motec Systems C185 Bedienungsanleitung

Beijing ART Tech
Beijing ART Tech USB2832 Bedienungsanleitung

Rotronic
Rotronic HygroLog HL20 Bedienungsanleitung

Racelogic
Racelogic VBOX LapTimer Bedienungsanleitung

Edu-Logger
Edu-Logger 900-240 Bedienungsanleitung