MuxLab 500811 Bedienungsanleitung

P/N: 94-000785-B SE-000785-B
MuxLab Pro Digital Network Controller (MNC)
(Model: 500811)
Operation Manual

© MuxLab Inc. ProDigital Network Controller (MNC)
Page 2
Copyright Notice:
Copyright © 2014 MuxLab Inc. All rights reserved.
Printed in Canada. No part of this publication may be reproduced, stored in a retrieval system, or
transmitted in any form or by any means, electronic, mechanical, photocopying, recording or
otherwise without prior written permission of the author.
Trademarks:
MuxLab is a registered trademark of MuxLab Inc.

© MuxLab Inc. ProDigital Network Controller (MNC)
Page 3
Table of Contents
1. Overview.....................................................................................................................................4
1.1. Description...............................................................................................................................4
1.2. Features....................................................................................................................................5
2. Technical Specifications ............................................................................................................6
3. Installation and Use ...................................................................................................................7
3.1. Part List....................................................................................................................................7
3.2. Product Overview ....................................................................................................................8
3.3. Installation Procedure ..............................................................................................................9
3.4. Ethernet Web Interface –Device Management .....................................................................23
3.5. Mobile Interface.....................................................................................................................34
4. Troubleshooting .......................................................................................................................38
5. Appendix...................................................................................................................................39
A. IP Commands.........................................................................................................................39
6. Product Warranty Policy........................................................................................................46

© MuxLab Inc. ProDigital Network Controller (MNC)
Page 4
1.
Overview
1.1.
Description
The MuxLab Pro Digital Network Controller is a Linux-based PC that allows users to
control hub-installed MuxLab products.
When installed on a local area network (LAN), the MuxLab Pro Digital Network
Controller can scan the LAN for MuxLab products and allows the user to configure
and control these products through an Ethernet Web interface.
Figure 1: System Overview
Applications include but are not limited to commercial and residential AV systems,
classroom projector systems, digital signage, video wall systems, boardroom systems,
multi-room systems, classroom training, retail systems, collaborative PC systems, and
medical information systems.
TX
TX
TX
RX
RX
RX
Pro Digital
Network Controller
Router (w/WiFi)
PoE (PSE) Ethernet Switch
Tablet or
Smartphone

© MuxLab Inc. ProDigital Network Controller (MNC)
Page 5
1.2.
Features
(Front View) (Rear & Side View)
Figure 1: Pro Digital Network Controller
Front Panel
Power LED
Power button
Back Panel
VGA video port
HDMI video port
LAN port (RJ-45 jack)
Audio in (3.5 mm)
Audio out (3.5 mm)
Micro SD memory slot
K lock
Power connector
Side Panel
Three (3) USB 2.0 ports

© MuxLab Inc. ProDigital Network Controller (MNC)
Page 6
2.
Technical Specifications
MuxLab ProDigital Network Controller
CPU
Intel Z3735F
Memory
2GB DDR3
BIOS
AMI BIOS
VGA
Resolution up to 1920 x 1200
Keyboard and Mouse
USB keyboard and mouse (sold separately)
Peripherals
• USB 2.0 ports (3x)
• micro SD slot (1x)
• Network interface (1x)
•Audio in and out
Operating System
Ubuntu 15.04
Operating Temperature
5 ºC to 50 ºC
Dimensions
4.52 x 4.52 x 1.4 inch (115 x 115 x 35 mm)
Weight
1.1lbs (0.5kg)
Accessories Included
External Power Adaptor
Regulatory
FCC, CE, RoHS, WEEE
Order Information
500811 Pro Digital Network Controller
Table 1: Technical Specifications

© MuxLab Inc. ProDigital Network Controller (MNC)
Page 7
3.
Installation and Use
3.1.
Part List
The MuxLab Pro Digital Network Controller comes with the following parts:
• Base unit (1x)
• External Power Adapter (1x)
Please verify that both parts are present before proceeding.
Figure 2: Base Unit
Figure 3: External Power Adaptor

© MuxLab Inc. ProDigital Network Controller (MNC)
Page 8
3.2.
Product Overview
The external connections and connection indicators of the MuxLab Pro Digital
Network Controller are detailed in
A1A2A3A4A5A6A7A9
A8
Figure 4: Rear Panel and Figure 5: Side Panel. Please familiarize yourself with them
before installing the unit.
A1A2A3A4A5A6A7A9
A8
Figure 4: Rear Panel
A1= DC Power
A2= VGA video
A3= HDMI video
A4= RJ45 Ethernet
A5= Audio in
A6= Audio out
A7= Micro SD Memory Slot
A8 = K Lock
A9 = Wifi antenna

© MuxLab Inc. ProDigital Network Controller (MNC)
Page 9
B1B2B3
Figure 5: Side Panel
B1= USB 2.0 #1
B2= USB 2.0 #2
B3= USB 2.0 #3
3.3.
Installation Procedure
Note that the examples below assume that the Ethernet Switch used does not support
WiFi, and a Router with WiFi capability is required in order to communicate with
smartphones and tablets for control purposes.
Setting the Ethernet Switch & Router to the same Subnet as MuxLab Devices:
The MuxLab Pro Digital Network Controller comes with a default static IP address of
192.168.168.50 (with DHCP disabled). The MuxLab AV over IP Transmitters and
Receivers are set to support DHCP by default. When no DHCP server is available the
AV over IP Transmitters and Receivers fallback to a static IP address of
192.168.168.55 (for the 500752, 500753, 500754 and 500756 Transmitters) and
192.168.168.56 (for the 500752, 500753, 500754 and 500756 Receivers), and
192.168.168.58 (for the 500758 and 500759 Transmitters) and 192.168.168.59 (for the
500758 and 500759 Receivers).
These MuxLab products (MNC, and the AV over IP Transmitters & Receivers) work
in conjunction with a PoE (PSE) Ethernet Switch (MuxLab recommends the Cisco
SG300 Series) and a Router of your choice with WiFi capability to be able to
communicate with a smartphone or tablet. The use of a smartphone or tablet to
manage the MuxLab devices with third party software applications is optional but is
the most common method of control and generally preferred, however MuxLab
devices may also be managed via the Pro Digital Network Controller web interface.
In order for the DHCP server within the Ethernet Switch to support the MuxLab
device subnet, set the static IP of the Ethernet Switch to 192.168.168.1 (recommended
setting). Refer to the Ethernet Switch manual for instructions on how to accomplish
this. MuxLab also has a guide specific to the Cisco SG300 Series, see document SE-
000819-A (Configuring Network Setting of the Ethernet Switch & MuxLab AV over

© MuxLab Inc. ProDigital Network Controller (MNC)
Page 10
IP Devices), which can be found on MuxLab’s website under any of the AV over IP
product pages (as a download under the Operation Manual sub-category).
The Router with WiFi capability, must also be placed on the same subnet as the
MuxLab devices and it should be set with a Static IP address, we recommend using a
Static IP address of 192.168.168.2. Refer to your Router documentation on how to
accomplish this.
Setting MuxLab Devices, Ethernet Switch and Router to an Existing Subnet:
If the MuxLab AV over IP devices are being installed in an existing environment that
has a working subnet already configured that cannot be easily changed, then the
subnet of the MuxLab devices, the Ethernet Switch (if a new Ethernet Switch is
required), and the Router with Wifi (if a new Router is required) must be changed in
order to match the existing subnet. For this case we will use 192.168.2.x as an
example subnet already in place and which must be supported. Note that this is only
an example and may not necessarily reflect your actual subnet address.
If the Ethernet Switch does not already reside in the example subnet of 192.168.2.x,
then set the static IP of the Ethernet Switch to a free static IP address (for the sake of
this example we will use an IP address of 192.168.2.1). Refer to the Ethernet Switch
manual for instructions on how to accomplish this. MuxLab also has a guide specific
to the Cisco SG300 Series, see document SE-000819-A (Configuring Network Setting
of the Ethernet Switch & MuxLab AV over IP Devices), which can be found on
MuxLab’s website under any of the AV over IP product pages (as a download under
the Operation Manual sub-category).
If the Router with WiFi does not already reside in the example subnet of 192.168.2.x,
then set the static IP of the Router to a free static IP address (for the sake of this
example we will use an IP address of 192.168.2.2). Refer to your Router
documentation on how to accomplish this.
The MuxLab AV over IP Transmitters and Receivers are set by default to support
DHCP, and will automatically be set to the subnet specified by the DHCP Server.
These units need only be physically connected into the network as described in their
respective Installation Guides and by using the 500811 Pro Digital Network Controller
to discover them. But before the MNC can be used, the new MNC subnet must also be
set.
To change the subnet of the MNC requires a two-step process:
Process 1: Configuring the IP address of the MNC
Process 2: Physically installing the MNC in the network
Note:
• An example subnet address of 192.168.2.x of the existing network on which the MNC will
be installed is assumed for this example process.
Andere Handbücher für 500811
3
Inhaltsverzeichnis
Andere MuxLab Controller Handbücher