Nachi FD Bedienungsanleitung

FD CONTROLLER
INSTRUCTION MANUAL
EtherNet/IP Function
・Before attempting to operate the robot, please read through this operating manual
carefully, and comply with all the safety-related items and instructions in the text.
・The installation, operation and maintenance of this robot should be undertaken only
by those individuals who have attended one of our robot course.
・When using this robot, observe the low related with industrial robot and with
safety issues in each country.
・This operating manual must be given without fail to the individual who will be actually
operating the robot.
・Please direct any queries about parts of this operating manual which may not be
completely clear or any inquiries concerning the after-sale service of this robot to any
of the service centers listed on the back cover.
4th edition
1403, TFDEN-122-004, 002


Table of Contents
1
Table of Contents
Chapter 1 Outline
1.1 What is EtherNet/IP? .................................................................................................................. 1-1
1.2 EtherNet/IP of this controller....................................................................................................... 1-2
1.2.1 I/O signals........................................................................................................................... 1-2
1.2.2 Performance table .............................................................................................................. 1-3
1.2.3 Hardware configuration ...................................................................................................... 1-3
1.2.4 Hardware settings............................................................................................................... 1-4
1.2.5 EtherNet/IP network ........................................................................................................... 1-4
Chapter 2 Needed Parts
2.1 Needed Parts .............................................................................................................................. 2-1
Chapter 3 Signal allocation
3.1 Field bus I/O signals ................................................................................................................... 3-1
3.1.1 When software PLC is enabled .......................................................................................... 3-1
3.1.2 When software PLC is disabled.......................................................................................... 3-1
3.1.3 Assigning signals beyond the number of channels ............................................................ 3-2
3.2 EtherNet/IP signal assignment ................................................................................................... 3-2
Chapter 4 Setting
4.1 Setting procedure ....................................................................................................................... 4-1
4.2 EtherNet/IP slave settings .......................................................................................................... 4-3
4.2.1 Fieldbus settings................................................................................................................. 4-3
4.2.2 EtherNet/IP (slave) settings................................................................................................ 4-4
4.3 EtherNet/IP master settings........................................................................................................ 4-5
4.3.1 Fieldbus settings................................................................................................................. 4-5
4.3.2 EtherNet/IP (Master) Settings.............................................................................................4-6
4.3.3 Setting of scan list .............................................................................................................. 4-7
4.4 Change of the Network Environment........................................................................................ 4-22
4.4.1 Resetting of the fieldbus and EtherNet/IP (master and slave) ......................................... 4-22
4.4.2 Resetting of Scanlist......................................................................................................... 4-23
4.5 Fieldbus Channel Monitor......................................................................................................... 4-28
4.6 Output signal “Fieldbus acting correctly” .................................................................................. 4-29
4.7 Error check delay for EtherNet/IP............................................................................................. 4-30
Chapter 5 Error Detection
5.1 Error Detection on EtherNet/IP module ...................................................................................... 5-1
5.2 Error Detection on this Controller ............................................................................................... 5-3
5.3 Detailed Field Bus Error Settings ............................................................................................... 5-4

Table of Contents
2

1.1 What is EtherNet/IP?
1-1
Chapter 1 Outline
1.1 What is EtherNet/IP?
EtherNet/IP is the industrial network system which is possible to transfer large capacity and wide variety of data
with high speed.
By connecting the limit switches, photo sensors, operating boxes and industrial equipments such as robot
through this network, these equipments are connected with logical access (network I/O). So communication
between the equipments where the hardware connection was hard to be achieved is now improved and diagnosis
of equipments is enabled.
Network speed from 10 Mbps to 100 Mpbps are selectable depending on the network size. (selected
automatically depending on the network)
Two types of communication methods (I/O communication and Explicit communication) are available when
using EtherNet/IP.
・I/O communication: Communication at high-speed cycle
・Explicit communication: Communication for settings / monitoring
In this controller, only I/O communications for transferring I/O signals over the network are supported.
The diagram below gives an example of this controller connected to an EtherNet/IP network.
EtherNet/IP is the registered trademark of ODVA (Open DeviceNet Vender Association, Inc.).
Fig. 1.1.1 EtherNet/IP connection diagram
With EtherNet/IP, the device called a “master” when using DeviceNet/IP is called a “scanner,” and the device
called a “slave” is called an “adapter.”
Controller (scanner)
Switching hub
PC
Various
sequencers
Various
sensors
Various
I/O devices
This
controller

1.2 EtherNet/IP of this controller
1-2
1.2 EtherNet/IP of this controller
1.2.1 I/O signals
EtherNet/IP of this controller supports up to four independent networks (channels). Each of these channels
functions independently as a scanner or an adapter.
The diagram below gives an operational block diagram of the EtherNet/IP.
Physical I/O Software PLC Logical I/O
Network I/O
Fieldbus output
(Y1000 ~Y3047)
Logcal output
(O0000 ~O2047)
Standard output
Standard input
Fixed output
Fixed input
Extended output
Extended input
Fieldbus input
(X1000 ~X3047)
Logical input
(I0000 ~I2047)
Fig. 1.2.1 Operational block diagram
Two methods of accessing network I/O from this controller are available.
When using PLC, access is carried out using field bus I/O having 2048 input points (X1000 to X3047) and 2048
output points (Y1000 to Y3047).
When not using PLC, access is carried out using logical I/O having 1888 input points (I161 to I2048) and 1888
output points (O161 to O2048).

1.2 EtherNet/IP of this controller
1-3
1.2.2 Performance table
Table 1.2.1 Performance table
Item Specification
Number of channels Up to four installed channels
Scanners / adapters Scanners and adaptors can be used.
Adaptors can be configured independently for each channel.
Communications Supports I/O communication only
Number of I/O signals
Capable of using up to 2048 input signals (256 bytes) and up to 2048
output signals (256 bytes) for all channels combined, communication
can be covered by the general-purpose signals of this controller.
(When using embedded PLC)
Addresses The IP address, subnet mask, and default gateway of this controller
can be set for each channel by key entry from the teach pendant.
Transfer rate 10 Mbps, 100 Mbps
The transfer rate is set automatically.
Processing of input data when a
communication error occurs
You can select whether to maintain or clear input signal status when a
communication error occurs.
Possible causes of errors are given below.
・Hardware error of the EtherNet/IP board
・Broken cable or hub error
・Incorrect node address setting
CAUTION
I/O status may not be normal if an error occurs and the LED indicating a problem lights.
Take great care as the interlock functions of the robot, jigs, and/or other devices may fail
to operate normally, resulting in unintended operation.
IMPORTAN
T
The following configuration tool (prepared by the user) is necessary to use the scanner
function.
・RsNetworx for EtherNet/IP (from Rockwell)
1.2.3 Hardware configuration
EtherNet/IP board should be mounted on one of three PCI slots in CPU unit.
Rack unit
Three PCI slots
#1 #2 #3
Slot ID
Fig. 1.2.2 PCI slots

1.2 EtherNet/IP of this controller
1-4
1.2.4 Hardware settings
The EtherNet/IP function is performed using HMS EtherNet/IP module (“Anybus-S Ethernet module” or
“Anybus-M Ethernet scanner module” (HMS Industrial Networks)) that is mounted on field bus base board.
Up to two modules can be mounted on field bus base board.
It’s unnecessary to change the dip switches on field bus base board and HMS EtherNet/IP module.
EtherNet/IP
(Module 2)
Dip switch
EtherNet/IP
(Module 1)
UM236
LED Dip switches Cable connector
Fig. 1.2.3 Appearance of field bus base board
Fig. 1.2.4 Appearance of HMS EtherNet/IP module
1.2.5 EtherNet/IP network
Use category 5 or higher Ethernet cable for the EtherNet/IP network. In addition, make sure that the length
of Ethernet cable as measured from switches to this controller does not exceed 100 m.
In order to maintain normal communication status, be sure to use a switch having the functions given below
for the switch to be used as the accumulation point for the EtherNet network.
・Equipped with an L2 switch for preventing signal collision
・Capable of 100 Mbps communications
・Supports full duplex communications
If the network is large and traffic is high, be sure to configure the network using switches equipped with
Quality of Service (QOS) and Virtual Local Area Network (VLAN) functions so that delays in I/O transfer do not
occur.

2.1 Needed Parts
2-1
Chapter 2 Needed Parts
2.1 Needed Parts
Optional hardware is required to use the EtherNet/IP.
Table 2.1.1 Optional hardware required for EtherNet/IP
Part name Product number
Single scanner specification AX10-OP130-A
Single adapter specification AX10-OP130-B
Scanner + Adapter AX10-OP130-C
Dual adapter specification AX10-OP130-D
EtherNet/IP board
(Field bus base board + HMS EtherNet/IP module)
Dual scanner specification AX10-OP130-E
Product numbers are as follows if you want to purchase the field bus base board and the HMS EtherNet/IP
module separately.
Table 2.1.2 Product numbers of each part
Part name Product number
Field bus base board UM236-10
HMS EtherNet/IP scanner module AB5057-B
HMS EtherNet/IP adapter module AB4173-B
The following configuration tool (prepared by the user) is necessary to use the scanner function.
・ RsNetworx for EtherNet/IP (from Rockwell)

2.1 Needed Parts
2-2
NOTE
Inhaltsverzeichnis
Andere Nachi Robotik Handbücher
Beliebte Robotik Handbücher anderer Marken

STEMCenter USA
STEMCenter USA Pi-Bot v2.00 Bedienungsanleitung

SunFounder
SunFounder PiDog Bedienungsanleitung

Universal Robots
Universal Robots UR5 Bedienungsanleitung

Universal Robots
Universal Robots E Series Bedienungsanleitung

YASKAWA
YASKAWA MOTOMAN-MPL80 II Bedienungsanleitung

EFORT
EFORT ECR5 Gebrauchsanweisung