nantlife Smart Body Bedienungsanleitung

English
Smart Body Scale
Simple Operaon
High Measuring Accuracy
USER MANUAL

1English
NantCare LLC, 2929 N 44th Street
Phoenix, Arizona, 85018-7239 - USA
1-855-NANTCARE - Email: support@nantcare.com
www.nantcare.com
Copyright© Revision 09 2012
Smart Body Scale
2

English
English
Table of Contents
1 Table of Contents
1.1 Introducon P 4
1.2 Intended Use P 4
1.3 Safety Informaon P 4
1.3.1 Operang the Device P 4
1.3.1.1 Warnings p 4
1.3.1.2 Cauons P 6
1.4 Before Taking a Measurement P 6
2Operang Instrucons P 7
2.1 Know your NantLife Body Scale P 7
2.2 Unit Display P 7
2.3 Display & Label Symbols P 8
2.4 Baeries Installaon P 8
2.5 Baeries Replacement P 9
2.6 Taking a Measurement P 11
3 Care and Maintenance P 12
3.1 Cleaning P 12
3.2 Maintenance P 12
3
4Troubleshoong P 12
4.1 Error Indicators P 12
4.2 Troubleshoong Tips P 13
5 FCC Statement P 14
6 CE mark P 14
7 Warranty P 15
8Specicaons P 16
9Manufacturer P 17

4
1.1 Introducon
Thank you for purchasing the NantLife Smart Body Scale.
Weight and BMI
Four load cells measure weight. BMI is calculated and displayed
based on weight.
Body composion
The scale measures body mass using bioimpedance analysis. ITO
electrodes form a paern on the top of the scale, and send a small,
safe signal through the body to measure impedance.
The NantLife Smart Body Scale comes with the following compo-
nents:
• Monitor with LCD backlit display
• Displays Weight & BMI
• Tempered glass plaorm
• Bluetooth® Low Energy data transmission
• User Manual
• User Guide
• Units lb, kg
• Measurement range 20–350 lbs (9–158 kg)
Refer to the following website for information on Bluetooth
connection and pairing:
www.bluetooth.com/Pages/advice-how-to.aspx
Thank you for your trust; we are available at any me for service
and product quesons.
More informaon at: www.NantLife.com
1.2 Intended Use
• This device is intended for use in measuring body weight and
body mass index by people above 12 years old to geriatric in the
home.
Under eighteen (18) years of age, use with adult supervision.
• The Smart Body Scale is not intended to be a diagnosc device.
• Never change your medicaon on the basis of results you have
obtained. The evaluaon of the measurements and the
treatment may only be carried out by the treang physician.
• The Blood Pressure Monitor comes with carpet feet adaptors.
Make sure to add them to the exisng feet is you are using the
Body Scale on a carpeted oor.
• Do not let infants or person who cannot express
their intenon use the Body Scale.
1.3 Safety Informaon
1.3.1 Operang the Device
To assure the correct use of the monitor, always follow the warnings
and cauons lied in this instrucon manual.
1.3.1.1 Warnings
Read all of the informaon in the instrucon manual and any other
instrucon in the box before operang the unit.
If you experience discomfort during a measurement- Step out of
the Body Scale .
Please contact our Customer Service at support@NantCare.com

English
5
in addion, please note:
• To produce precise readings, the device should be placed on a
hard and leveled surface.
• Do not under any circumstances use the device in the bath or
the shower. If, however, liquid gets into the device, you must
remove the baeries immediately and refrain from further
use. Contact our service department (see page 17).
• The device may not be used near a nuclear magnec tomo-
graphic resonance.
• Using components that are not part of the scope of delivery
can produce faulty measurements (Excepon: baery replace-
ment).
• DO NOT subject the body scale to strong shocks such as drop-
ping the unit on the oor.
• DO NOT damage the baeries. If baery uid gets in your
eyes, immediately rinse with plenty of clean water and contact
a physician immediately.
• Do not use if you have a pacemaker or other internal medical
device, or are pregnant.
• Not intended for use by children under 10. Always consult
your physician.
• Slippery when wet.
• Aria is designed to work in a humid bathroom environment.
Some condensaon on the scale is expected (due to hot show-
ers, etc.) and will not damage the scale. The scale should not
be submerged. Avoid splashing large amounts of water on the
scale. To prevent slipping / accidents, please thoroughly dry
the glass top before stepping on the scale.
• Keep away from source of re and/or heat.
• Store the device in a clean, safe locaon.
• DO NOT disassemble the body scale or its accessories.
• DO NOT use the body scale in the proximity of a MRI or CT.
• DO NOT use the body scale in the presence of ammable
anesthecs.
• Explosion hazard: DO NOT use the body scale in an explosive
atmosphere.
• Chemicals from LCD display panel are toxic if ingested. Use
cauon if the blood pressure meter display screen is broken.
• The body scale is intended only as an adjunct in paent as-
sessment. It must be used in conjuncon with other methods
of assessing clinical signs and symptoms.
• Use only 1.5V AA alkaline baeries with this device. Other
type of baery may damage the unit.
• Follow local ordinances and recycling instrucons regarding
disposal or recycling of the device components, including bat-
teries.
• Only the authorized service personnel can repair this device.

6
1.3.1.2 Cauons
• Excessive user movement may cause inaccurate readings
• All NantLife devices are designed to be compliant with rules
and regulaons in locaons they are sold and are labeled as
required.
• Any changes or modicaons to NantLife equipment, not
expressly approved by NantLife void the user’s authority to
operate the device.
• Autoclaving, ethylene oxide sterilizing, or immersing the blood
pressure meter in liquid may cause inaccurate measurements.
1.4 Before Taking a Measurement
General informaon about weight and BMI measurements:
Your healthcare providers want to get an accurate picture of your
blood pressure and chart what happens over me. Starng at age
20, the American Heart Associaon recommends a regular blood
pressure screening.
Your doctor will evaluate the data you have stored, once you share
it with her/him, and will immediately have a beer overview of the
course of your blood pressure measurements. You will be control-
ling and supporng the monitoring of your doctor’s treatment.
To ensure a reliable reading follow these recommendaons:
• Avoid eang, drinking alcohol, smoking, exercising, and bath-
ing for more than 30 minutes before taking your measure-
ment. Rest for 15 minutes before taking the measurement.
• Do not take measurement during stressful mes.
• Remove ght-ng clothing from the arm.
• Remain sll and do not talk during measurement.
• Try to measure your blood pressure at about the same me
every day for consistency.
• Wait 3 minutes between measurements to allow the arteries
to return to normal condion.

English
7
2 Operang Instrucons
2.1 Know your NantLife Body Scale Removable Top Cover
Air Jack - Air Plug
Buon
LCD display
Note: the baery compartment is located at the boom of
the Body Scale
Cauon: Substuon of a component dierent from that
supplied might result in measurement error.
Weight
Diastolic Blood Pressure Value
Wireless Signal Indicator
Baery Level Indicator
2.2 Unit Display

8
2.3 Display Symbols
Symbols Operaon Measure/Soluon
SYS (mm/Hg) Displays systolic value Upper value
DIA (mm/Hg) Displays diastolic value Lower value
PULSE (1/min) Displays pulse Pulse rate per
minute
Baeries indicator,
empty
Replace all the
baeries
Mobile Wireless
Data Transmission
See page 10
ER (#) Error Message See page 12
Manufacturer informaon
Read instrucons carefully before use
There are specic warnings or precauons associ-
ated with this device
Disposed of separately from normal household
waste
Type BF Applied Part
4.0 Bluetooth® Low Energy
2.4 Baeries Installaon
NOTE: Baeries are not included
1. Press down the ▼ indicator on the baery cover and
slide the cover o in the direcon of the arrow.

English
9
2.5 Baeries Replacement
When the low baery indicator appears on the display screen,
turn o the monitor and remove all the baeries.
Replace with 4 new “AA” 1.5V alkaline baeries.
WARNING:
If baery uid gets in your eyes, rinse with plenty of clean water
and contact a physician immediately.
CAUTION:
Dispose of the device and empty baeries according to appli-
cable local regulaons.
Unlawful disposal may cause environmental polluon.
AA 1.5V AA 1.5V
AA 1.5V AA 1.5V
2. Install the 4 “AA” baeries so the + (posive) and the –
(negave) match the polaries of the compartment.
3. Replace the baery cover

10
2.6 Applying the Arm Cu
CAUTION: Read all the informaon in the instrucon manual and
any other documents in the box before operang the unit.
1. Open the top cover of the NantLife Blood Pressure Monitor
2. Gently, take the cu out of the compartment
3. Make sure the air plug is securely inserted into the air jack
4. Remove clothing from your upper (preferably le) arm
5. Apply the cu to your arm so the arrow is centered on the inside
of your arm and aligned with your middle nger. The air tube runs
down the inside of your arm. The boom edge of the cu is ap-
proximately ½” above your elbow joint (2cm)
6. Wrap the cu rmly in place using the closure strip
7. Keep your arm very sll during the measurement
Notes: Be careful not to rest your arm on the air tube. This will
restrict the ow of air going to the cu.
Inhaltsverzeichnis
Andere nantlife Skala Handbücher