7
W415-0847 / 09.15.09
2.3 GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!
2.5 CARE OF GLASS
5.1
DO NOT CLEAN GLASS WHEN HOT! DO NOT USE
ABRASIVE CLEANERS TO CLEAN GLASS.
Buff lightly with a clean dry soft cloth. Clean both sides
of the glass after the rst 10 hours of operation with a
recommended replace glass cleaner. Thereafter clean
as required. If the glass is not kept clean permanent
discoloration and / or blemishes may result.
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
!
WARNING
LA VITRE CHAUDE CAUSERA
DES BRÛLURES.
NE PAS TOUCHER LA VITRE
AVANT QU’ELLE AIT REFROIDI.
NE JAMAIS LAISSER LES
ENFANTS TOUCHER LA VITRE.
!
AVERTISSEMENT
RATES AND EFFICIENCIES
NATURAL GAS PROPANE
Altitude 0 - 2,000* 0 - 2,000*
Maximum input 6,000 6,000
Minimum Inlet Gas Supply Pressure 4.5” Water Column 11” Water Column
Maximum Inlet Gas Supply Pressure 7” Water Column 13” Water Column
Manifold Pressure Under Flow Conditions 3.5” Water Column 10” Water Column
* When the appliance is installed at elevations above 2,000ft and in the absence of specic recommendations
from the local authority having jurisdiction, the certied altitude input rating shall be reduced at the rate of 4%
for each additional 1,000ft.
This appliance is only for use with the type of gas indicated on the rating plate. For rating plate location, see
either “DIMENSIONS” or “RATING PLATE” section. This appliance is not convertible for use with other gases,
unless a certied kit is used.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
The rating label is located under the control panel and is chained to the appliance. DO NOT REMOVE.
2.4 RATING PLACE LOCATION
TITLE: RATING PLATE (GVFT8)
REVISIONS:
LABEL #: W385-0480
DATE: 06.17.09_JK
MATERIAL:
CLASS IIIA-2 PERMANENT LABEL, WATERPROOF, 10 MIL VELVET GLOSS LEXAN
BLACK ON WHITE BACKGROUND, HOLE TO BE 1/4” DIAMETER.
MAX OVERALL DECAL SIZE:
3.500" x 6.000"
SERIAL NUMBER TO BE ASCENDING FROM GVFT8016809
CERTIFIED UNDER : ANSI Z21.11.2-2007 VOLUME II, UNVENTED ROOM HEATER
THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME,
WHERE NOT PROHIBITED BY LOCAL CODES. THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON
THE RATING PLATE. THIS APPLIANCE IS NOT FIELD CONVERTIBLE FOR USE WITH OTHER GASES.
THIS IS A GAS-FIRED UNVENTED ROOM HEATER THAT REQUIRES ADEQUATE COMBUSTION AND VENTILATION AIR.
I
N
T
E
R
T
E
K
W
a
r
n
o
c
k
H
e
r
s
e
y
CM US
ALTITUDE
INPUT
ORIFICE
MANIFOLD PRESSURE: 3.5" WATER COLUMN
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN
MANIFOLD PRESSURE: 10" WATER COLUMN
MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
0-2000FT (0-1370m)
6,000 BTU/h
#69
0-2000FT (0-1370m)
6,000 BTU/h
#56
CERTIFIED FOR USA
GVFT8N
MODEL
GVFT8P
MODEL
W385-0480
GVFT8
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAME. DO NOT USE ACCESSORIES
NOT APPROVED FOR USE WITH THIS APPLIANCE. IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTAINANCE CAN
CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED WITH THIS
APPLIANCE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
TOP 18” FLOOR 8”
SIDES 1” BACK 0”
TOP, SIDES & BACK AS PER ABOVE. FOR FINISHING
MATERIAL, SEE OWNERS MANUAL. MADE IN CANADA
WOLF STEEL LTD, BARRIE, ON, CANADA
SERIAL NUMBER:
ELECTRICAL RATING: 115v 0.82AMP, 60HZ
REFERENCE #16437
PAGE 2 OF 2
SPECIFICATIONS:
(NATURAL GAS) (PROPANE)
CONTROL: COPRECI T15 CONTROL: COPRECI T15
OXY PROTECTOR SIT: #9099 OXY PROTECTOR SIT: #9266