DESCRIPTION
This Product Guide describes the installation and operating instructions of our DS3
model DOOR STATION Controller, which is designed to connect to a Specially
designed Door Phone (see page 4), when used on an ordinary PSTN residential
telephone line.
Your DS3 Controller is completely TRANSPARENT in operation, so it will not affect the
normal operation of your telephone line in any way. It is Designed to RING all of your
Normal Telephones when a Visitor presses the Call Button of the attached Door Phone.
You need only Answer ANY Ringing Telephone to converse with your visitor.
Model DS3 has the additional capability where it cans DIAL OUT to your Cell Phone
(or any other user programmed number) so that you can still Answer your Door
Phone when you are away from home. DS3 can either DIAL OUT immediately, or
after a User Programmed Number of Unanswered Rings.
ONE or TWO Door Phones can be connected to the DS3 unit. They must be
connected in parallel with each other. Either Door Phone can trigger a Door Phone
call. If you use TWO Door Phones connected in parallel, then Audio will be present
at both Door Phones at the same time.
If you wish to operate 2 completely separate Door Phone zones, when using 2 Door
Phones, you can do so by fitting an additional Model DS1 Controller (our less
expensive model without Lock Control and Dial Out) on the same telephone line. In
this situation, each Door Phone will then have separate audio communication and
you will be able to use the Dual Lock Control of DS3 to control up to 2 separate lock
zones.
If you need the additional features of DS3 at Both Door Phone Zones, you should
use another Model DS3 Controller with Dial Out and Call Advice Tones.
Once correctly installed, DS3 will RING your all of telephones that are connected to
it as soon as it is activated by a visitor pressing the Call Button of the attached Door
Phone. Unlike the more basic Model DS3 and DS2 Controllers, DS3 also has the
ability to select from 4 different ring outputs.
DS3 will work with both Corded and Cordless Phones. A small number of Older
Cordless Telephones may not ring differently as they are designed to ignore the
incoming ring pattern and output their own ring. For this reason, your unit can be
set to output FIVE quick ‘beep’ tones (advice tones) immediately after answer, to
advise you that the incoming call is from your Door Phone.

Natcomm Page 3
OPERATION WITHOUT A TELEPHONE LINE
DS3 will also work WITHOUT connection of a Telephone Line. In this situation, leave
the Line Input port of DS3 vacant (see the diagram below).
DS3 will ring all attached telephones as normal. This will suit the many users that no
longer use a fixed telephone line. The diagram below shows a wiring diagram used
when a Single Lock Control relay is being used.

Page 4 Natcomm
DOOR PHONE RANGE
A choice of Five Door Phones is provided for use with our range of Door Station Controller units:
Model DP1 - SURFACE MOUNT
Molded plastic unit, designed for easy surface mounting
direct onto your wall surface.
Blue LED Night illumination.
(100mm Wide, 133mm High, 32mm Depth).
Model DP2 - FLUSH MOUNT Compact Size
Marine Grade Stainless Steel face plate.
Touch Switch operation.
Available in Vertical (Displayed) or Horizontal orientation.
Blue LED Night illumination.
Optional Surface Mounting Kit is available.
(107mm Wide, 204mm High, 30mm (D).
Model DP3 - FLUSH MOUNT Standard Size
Marine Grade Stainless Steel face plate.
Fitted with a Sealed Perspex Camera Hole and rear Mounting Studs to
allow you to fit your own Camera. Vertical or Horizontal orientation.
Touch Switch operation.
Blue LED Night illumination.
Optional Surface Mounting Kit is available.
(130mm Wide, 264mm High, 37mm Depth).
Model DP4 - FLUSH MOUNT Standard Size
Fitted with a high resolution, low light Digital Colour CCD Camera.
BNC output. Available in Vertical or Horizontal orientation
Marine Grade Stainless Steel face plate
Available in Vertical (Displayed) or Horizontal orientation.
Touch Switch operation.
Blue LED Night illumination.
Supplied with Wall Mount Box to assist installation.
Optional Surface Mounting Kit is available.
(130mm Wide, 264mm High, 37mm Depth).
Model DP5 - FLUSH MOUNT Standard Size
Fitted with intelligent Pedestrian Access Keypad.
Touch Switch operation with 99 User Codes.
Available in Vertical (Displayed) or Horizontal orientation
Marine Grade Stainless Steel Face plate.
Blue and White LED Night illumination.
Supplied with Wall Mount Box to assist installation.
Optional Surface Mounting Kit is available.
(130mm Wide, 264mm High, 30mm Depth).

Natcomm Page 5
DOOR PHONE COVERS
If your Door Phone is not under cover, a Strong Transparent DOOR PHONE COVER
is highly recommended to prevent water from gradually permeating through to the
electronics of the Door Phone. RRP is just $A 39.00.
Model DPC1 for DP1 Door Phone
Model DPC2 for DP2 Door Phones
Model DPC3 for DP3, DP4, DP5 Door Phones
You can alternatively use one of our Surface Mounting Kits which provides a Rain
deflector. See below.
SURFACE MOUNTING KITS
Stainless Steel (304) Surface Mounting Kits are available for all Model DP2 to DP5
Door Phones, so that your Door Phone can be mounted ONTO a wall surface, rather
than into it.
Two separate surface mounting kits are available, to cater for the different sized DP2-
DP5 Door Phones:
Model SMK2 for DP2 Door Phones
Model SMK3 for DP3, DP4, DP5 Door Phones

Page 6 Natcomm
OPERATION
When a visitor at your door or gate presses the call button on your NATCOMM
Door Phone, DS3 will ring all of the telephones connected to your line up to 10
times (the number of rings can be changed).
By simply answering any ringing telephone on your line, you will be immediately
connected direct to your visitor, so that you can converse with them.
If you are already on a telephone call, the DS3 Controller will instead inject a faint
'Beeping Tone' into the background of your call to alert you. You will then be able
to place your existing call 'ON HOLD' and switch to the door or gate by simply
pressing the ## key (twice) on your telephone. To resume your original call, all
you need do is to press ## again. This can be done as many times as required.
If you have a LOCK MECHANISM fitted, you can open a gate or door lock during
this call and allow your visitor to enter, by simply pressing the * * key on your
telephone.
If you have the SECOND LOCK CONTROL FACILITY fitted, you can also open
an ALTERNATIVE gate or door lock during this call, by simply pressing * 2 on
your telephone. This command will release Gate Lock 2 until you Hang Up the
telephone.
Note:
Pressing *3 can also close the second internal relay and leave it closed.
Pressing *4 can also open the second internal relay and leave it open.
Alternatively, the SECOND LOCK RELAY option can be used to START and
STOP another Device such as a VIDEO CAMERA, DISPLAY MONITOR,
RECORDER or to TURN ON and then TURN OFF a 12V LIGHT (or a 240V Light
with the Power Control Unit Accessory).
The Other Device will be SWITCHED ON as soon as the Call Button is pressed
on the supplied Door Phone and will SWITCH OFF, 01-99 seconds after the Door
Phone call has terminated, as programmed on page 27.
The Second Relay can also be used to signal to a Home Automation system that a
Door Phone call has been initiated.

Natcomm Page 7
DIAL OUT OPERATION
If your site is unattended, DS3 can DIAL OUT and CONNECT THE DOOR PHONE
CALL to a Pre-Programmed Telephone Number or a Mobile Telephone number (See
Pages 25-26 for Programming Details).
It can do so Immediately, or only if the Door Phone call has not been answered internally
by a preset number of rings.
Dial Out Immediately (Press #1), Dial Out after Ring Count (Press #2) and Disable
Dial Out (Press #3) are all set via Touch Tone commands from ANY Telephone on your
line, at any time (except in Programming Mode).
To set ‘Unattended Mode’
(Dials out immediately)
Pick up any telephone, press #1 and then hang up.
(you will hear 1 ‘beep’ to confirm setting)
In this mode DS3 will DIAL OUT to the Programmed Number as soon as the Door
Phone is triggered by your visitor call.
To set ‘Attended Mode’
(Only Dials out after ring count)
Pick up any telephone, press #2 and then hang up.
(you will hear 2 ‘beeps’ to confirm setting)
In this mode DS3 will only DIAL OUT to the Programmed Number if the Door Phone
call is not answered before the preprogrammed ring count.
To set ‘Disable Dial Out’
(will not Dial Out)
Pick up any telephone, press #3 and then hang up.
(you will hear 3 ‘beeps’ to confirm setting)
This Mode will totally DISABLE the DIAL OUT facility:
Note - Your DS3 is set by DEFAULT to ‘Disable Dial Out’, to ENABLE DIAL OUT,
you MUST press #1 or #2 as appropriate.

Page 8 Natcomm
OPERATION SUMMARY
Your telephones will ring whenever a visitor at your door or gate presses the call
button on your Door Phone(s).
You can answer the Door Phone call by simply picking up any telephone
connected to your line. You will then be able to converse with your visitor.
If you have an ELECTRIC LOCK fitted, you can release it (open it) by pressing **
on your telephone.
If you are already on a telephone call and the Door Phone is activated by a visitor,
you will be alerted with a tone.
You can place your existing call 'ON HOLD' and switch to the DOOR PHONE at
your door or gate by pressing ## on your telephone.
You can return to the telephone call by pressing ## on your telephone.
If there is an incoming telephone call while you are on a DOOR PHONE call, you
will be alerted with a tone.
You can place your existing call 'ON HOLD' and switch to the telephone call by
pressing ## on your telephone.
To resume your original call, all you need do is press ## on your telephone again.
DS3 COMMANDS
** opens LOCK 1
*2 opens LOCK 2
*3 activate LOCK RELAY 2 (leave it ON)
*4 de-activate LOCK RELAY 2 (leave it OFF)
## switch between lines

Natcomm Page 9
SINGLE CORDLESS BASE STATION
Without Lock Operation
Note:
DP1 Door Phone
only requires 2 wires

Page 10 Natcomm
WITH SINGLE LOCK CONTROL
Note: DP1 Door Phone
only requires 2 wires